Long-term storage for reanalysis purposes: A stability study of extracts from post-explosion/burning residues of fuel-oxidizer explosive mixtures

被引:0
|
作者
Logrado, Lucio Paulo Lima [1 ]
Braga, Jez Willian Batista [2 ,3 ]
机构
[1] Natl Inst Criminalist, Brazilian Fed Police, SAIS Quadra 07 Lote 23, BR-70610200 Brasilia, DF, Brazil
[2] Univ Brasilia, Inst Chem, Cx Postal 4478, BR-70910900 Brasilia, DF, Brazil
[3] Natl Inst Sci & Technol Bioanalyt INCTBio, BR-13083970 Campinas, SP, Brazil
关键词
Post -explosion residues; Long-term storage; Stability; Explosives; Ion chromatography; Gas chromatography -mass spectrometry; MICROBIAL-DEGRADATION; INORGANIC EXPLOSIVES; ANION ADSORPTION; METAL-IONS; IDENTIFICATION; PERCHLORATE; KINETICS; COAL;
D O I
10.1016/j.forc.2024.100583
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Post-explosion residue analysis is vital in forensic chemistry, providing valuable insights into incidents involving explosives. One significant challenge in this field is preserving samples for long-term storage for reanalysis. Presently, many laboratories conducting post-explosion analyses worldwide do not retain samples for reanalysis purposes, since the extraction process for sample preparation often necessitates the complete consumption of the scarce material. Even in cases where a portion of the material remains, such as a swab, it is difficult to ensure its representativeness and select a specific portion for preservation. One possible solution to overcome this challenge is to consider preserving the extracts used in the analyses for potential reanalysis. However, the stability characteristics of these extracts are currently unknown. The results presented in this article provide valuable insights into the feasibility of long-term storage for samples containing target analytes in extracts from post-explosion/ burning residues of frequently encountered fuel-oxidizer explosive mixtures, such as flash powder, explosive emulsion, and black powder. These results shed light on the potential viability of preserving such extracts for future reanalysis, offering promising prospects for enhancing forensic investigations in this field. Based on the current findings, it has been demonstrated that the aqueous extracts can be effectively preserved as long-term storage samples for a minimum of 24 months, encompassing all the studied explosives. Only cyanate ion showed significant degradation among the 27 compounds studied. Additionally, the organic extract, specifically in the case of emulsion explosive, can be maintained for at least 12 months.
引用
收藏
页数:10
相关论文
共 1 条
  • [1] Assessment of Banknotes as a Matrix for Detecting Post-Explosion Residues of Fuel-Oxidizer Explosive Mixtures Using Ion Chromatography
    Logrado, Lucio Paulo Lima
    Braga, Jez Willian Batista
    Laboissiere, Joao Carlos Ambrosio
    [J]. BRAZILIAN JOURNAL OF ANALYTICAL CHEMISTRY, 2024, 11 (43):