Aortic valve laceration following rotational atherectomy: a case report

被引:0
|
作者
Othman, Farrah [1 ]
Yong, Gerald [1 ]
Whelan, Alan [1 ]
Ihdayhid, Abdul Rahman [1 ,2 ,3 ,4 ]
机构
[1] Fiona Stanley Hosp, Dept Cardiol, 11 Robin Warren Dr, Murdoch, WA 6150, Australia
[2] Harry Perkins Inst Med Res, Cardiovasc Res & Innovat Lab, Perth, Australia
[3] Curtin Univ, Curtin Med Sch, Perth, Australia
[4] Univ Western Australia, UWA Med Sch, Perth, Australia
基金
英国医学研究理事会;
关键词
Rotational atherectomy; Iatrogenic aortic valve laceration; TAVR for native pure aortic regurgitation; Case report; Complication; IMPLANTATION;
D O I
10.1093/ehjcr/ytae226
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Iatrogenic aortic valve injury during cardiovascular catheterization interventions is extremely rare. Severe aortic regurgitation that ensues can be catastrophic and the management is typically with surgical valve replacement or repair. Percutaneous management of native pure aortic regurgitation is difficult due to anatomical challenges and the limitations of current transcatheter heart valve technology to anchor in the absence of leaflet or annular calcification.Case Summary An 82-year-old female underwent rotational atherectomy (RA) for a severely calcified stenosis of the left anterior descending artery. The patient was discharged well following placement of two drug eluting stents. She represented to hospital 7 days later with acute pulmonary oedema. Bedside transthoracic echocardiography demonstrated new, severe AR with preserved left ventricular size and function. Review of the prior percutaneous coronary intervention revealed significant trauma to the aortic valve during RA, with contrast seen refluxing into the LV during diastole, evolving throughout the procedure. Given the patient was not an operative candidate, an oversized transcatheter aortic valve was successfully implanted. In the post-operative setting, the patient suffered a stroke. Extensive hypoattenuated leaflet thickening (HALT) and thrombus was seen on dedicated 4D CT imaging. She made full neurological recovery and valve function returned to normal following a period of anticoagulation.Conclusion Although iatrogenic aortic valve laceration is rare, this case highlights several important learning points including the importance of good guide catheter support during RA; the feasibility of Transcatheter Aortic Valve Replacement for pure native AR; and the detection and management of HALT.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Aortic laceration due to prolapse of the bicuspid aortic valve: Case report
    Sugita, T
    Matsumoto, M
    Nishizawa, J
    Matsuyama, K
    Morimoto, Y
    JOURNAL OF HEART VALVE DISEASE, 2001, 10 (03): : 375 - 376
  • [2] Aortic cusp perforation during rotational atherectomy: a case report
    Shah, Nihit
    Demetriades, Polyvios
    Maqableh, Ghaith M.
    Khan, Sohail Q.
    Shahid, Farhan
    EUROPEAN HEART JOURNAL-CASE REPORTS, 2023, 7 (04)
  • [3] Rotational atherectomy through a coronary artery bypass graft after transcatheter aortic valve implantation: a case report
    Illescas, Edgar
    Cuisset, Thomas
    Spychaj, Jean-Charles
    Deharo, Pierre
    EUROPEAN HEART JOURNAL-CASE REPORTS, 2020, 4 (05)
  • [4] Coronary Rotational Atherectomy in Patients Treated with Transcatheter Aortic Valve Implantation
    Lunardi, Mattia
    Pesarini, Gabriele
    Scarsini, Roberto
    Pighi, Michele
    Zivelonghi, Carlo
    Ferrero, Valeria
    Gottin, Leonardo
    Ribichini, Flavio
    STRUCTURAL HEART-THE JOURNAL OF THE HEART TEAM, 2019, 3 (06): : 471 - 477
  • [5] Combined rotational atherectomy and aortic balloon valvuloplasty as a bridge to transcatheter aortic valve replacement
    Ali, Omar
    Marmagkiolis, Konstantinos
    Cilingiroglu, Mehmet
    REVISTA PORTUGUESA DE CARDIOLOGIA, 2015, 34 (12) : 775.e1 - 775.e4
  • [6] Rotational atherectomy in a dire situation: a case report
    Mukhopadhyay, Saibal
    Batra, Vishal
    Yusuf, Jamal
    Kumar, Sravan
    EUROPEAN HEART JOURNAL-CASE REPORTS, 2021, 5 (08)
  • [7] A case report of fractured guidewire removal by rotational atherectomy
    Wang, Xu
    Ye, Jian
    Gao, Jun-Qing
    Liu, Zong-Jun
    JOURNAL OF CARDIOTHORACIC SURGERY, 2021, 16 (01)
  • [8] A case report of fractured guidewire removal by rotational atherectomy
    Xu Wang
    Jian Ye
    Jun-Qing Gao
    Zong-Jun Liu
    Journal of Cardiothoracic Surgery, 16
  • [9] Aortic valve laceration following coronary angiography and percutaneous coronary intervention
    Roy, James
    Manganas, Con
    Youssef, George
    Rees, David
    JOURNAL OF CARDIAC SURGERY, 2016, 31 (11) : 686 - 688
  • [10] Emergent Percutaneous Rotational Atherectomy to Bailout Surgical Transapical Aortic Valve Implantation: A Successful Case of Heart Team Turnaround
    Choudhury, Tawfiq
    Bakar, Shahrukh N.
    Kiaii, Bob
    Teefy, Patrick
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2019, 113 (06) : 1151 - 1154