Qualitative and quantitative image quality of coronary CT angiography using photon-counting computed tomography: Standard and Ultra-high resolution protocols

被引:0
|
作者
Vattay, Borbala [1 ]
Boussoussou, Melinda [1 ]
Vecsey-Nagy, Milan [1 ]
Kolossvary, Marton [2 ,3 ]
Juhasz, Denes [1 ]
Kerkovits, Nora [4 ]
Balogh, Hanna [4 ]
Nagy, Norbert [4 ]
Vertes, Miklos [4 ]
Kiss, Mate [5 ]
Kubovje, Aniko [4 ]
Merkely, Bela [1 ]
Horvat, Pal Maurovich [4 ]
Szilveszter, Balint [1 ,6 ]
机构
[1] Semmelweis Univ, Heart & Vasc Ctr, Varosmajor St 68, H-1122 Budapest, Hungary
[2] Gottsegen Natl Cardiovasc Ctr, 29 Haller Utca, H-1096 Budapest, Hungary
[3] Obuda Univ, Univ Res & Innovat Ctr, Physiol Controls Res Ctr, Becsi Ut 96-B, H-1034 Budapest, Hungary
[4] Semmelweis Univ, Med Imaging Ctr, Korany Sandor St 2, H-1082 Budapest, Hungary
[5] Siemens Healthcare GmbH, Forchheim, Germany
[6] 18 Hataror Ut, H-1122 Budapest, Hungary
关键词
Computed Tomography Angiography; Coronary CTA; Coronary Stents; Image Quality;
D O I
10.1016/j.ejrad.2024.111426
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: We aimed to identify the optimal reconstruction settings based on qualitative and quantitative image quality parameters on standard and ultra-high resolution (UHR) images using photon-counting CT (PCCT). Method: We analysed 45 patients, 29 with standard and 16 with UHR acquisition, applying both smoother and sharper kernel settings. Coronary CT angiography images were performed on a dual-source PCCT system using standard (0.4/0.6 mm slice thickness, Bv40/Bv44 kernels, QIR levels 0-4) or UHR acquisition (0.2/0.4 mm slice thickness, Bv44/Bv56 kernels, QIR levels 0-4). Qualitative image quality was assessed using a 4-point Likert scale. Image noise (SD), signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated in both the proximal and distal segments. Results: On standard resolution, larger slice thickness resulted in an average increase of 12.5 % in CNR, whereas sharper kernel led to an average 8.7 % decrease in CNR. Highest CNR was measured on 0.6 mm, Bv40, QIR4 images and lowest on 0.4 mm, Bv44, QIR0 images: 25.8 +/- 4.1vs.8.3 +/- 1.6 (p < 0.001). On UHR images, highest CNR was observed on 0.4 mm, Bv40, QIR4 and lowest on 0.2 mm, Bv56 and QIR0 images: 21.5 +/- 3.9vs.3.6 +/- 0.8 (p < 0.001). Highest qualitative image quality was found on images with Bv44 kernel and QIR level 3/4 with both slice thicknesses on standard reconstruction. Additionally, Bv56 with QIR4 on 0.2 mm slice thickness images showed highest subjective image quality. Preserved distal vessel visualization was detected using QIR 2-4, Bv56 and 0.2 mm slice thickness. Conclusions: Photon-counting CT demonstrated high qualitative and quantitative image quality for the assessment of coronaries and stents.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Image quality assessment of coronary artery segments using ultra-high resolution dual source photon-counting detector computed tomography
    Bie, Judith van der
    Sharma, Simran P.
    van Straten, Marcel
    Hirsch, Alexander
    Kamila, Putri Annisa
    Bos, Daniel
    Dijkshoorn, Marcel L.
    Booij, Ronald
    Budde, Ricardo P. J.
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 171
  • [2] First in-human quantitative plaque characterization with ultra-high resolution coronary photon-counting CT angiography
    Mergen, Victor
    Eberhard, Matthias
    Manka, Robert
    Euler, Andre
    Alkadhi, Hatem
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [3] Ultra-High-Resolution Coronary CT Angiography With Photon-Counting Detector CT Feasibility and Image Characterization
    Mergen, Victor
    Sartoretti, Thomas
    Baer-Beck, Matthias
    Schmidt, Bernhard
    Petersilka, Martin
    Wildberger, Joachim Ernst
    Euler, Andre
    Eberhard, Matthias
    Alkadhi, Hatem
    INVESTIGATIVE RADIOLOGY, 2022, 57 (12) : 780 - 788
  • [4] Dental imaging using an ultra-high resolution photon-counting CT system
    Maurice Ruetters
    Sinan Sen
    Holger Gehrig
    Thomas Bruckner
    Ti-Sun Kim
    Christopher J. Lux
    Heinz-Peter Schlemmer
    Sarah Heinze
    Joscha Maier
    Marc Kachelrieß
    Stefan Sawall
    Scientific Reports, 12
  • [5] Dental imaging using an ultra-high resolution photon-counting CT system
    Ruetters, Maurice
    Sen, Sinan
    Gehrig, Holger
    Bruckner, Thomas
    Kim, Ti-Sun
    Lux, Christopher J.
    Schlemmer, Heinz-Peter
    Heinze, Sarah
    Maier, Joscha
    Kachelriess, Marc
    Sawall, Stefan
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [6] Coronary Stenosis Quantification With Ultra-High-Resolution Photon-Counting Detector CT Angiography
    Eberhard, Matthias
    Candreva, Alessandro
    Rajagopal, Rengarajan
    Mergen, Victor
    Sartoretti, Thomas
    Stahli, Barbara E.
    Templin, Christian
    Manka, Robert
    Alkadhi, Hatem
    JACC-CARDIOVASCULAR IMAGING, 2024, 17 (03) : 342 - 344
  • [7] Ultra-high resolution coronary CT angiography on photon-counting detector CT: bi-centre study on the impact of quantum iterative reconstruction on image quality and accuracy of stenosis measurements
    Vecsey-Nagy, Milan
    Varga-Szemes, Akos
    Schoepf, U. Joseph
    Tremamunno, Giuseppe
    Fink, Nicola
    Zsarnoczay, Emese
    Szilveszte, Balint
    Graafen, Dirk
    Halfmann, Moritz C.
    Vattay, Borbala
    Boussoussou, Melinda
    O'Doherty, Jim
    Suranyi, Pal Spruill
    Maurovich-Horvat, Pal
    Emrich, Tilman
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 176
  • [8] The Importance of Temporal Resolution for Ultra-High-Resolution Coronary Angiography: Evidence From Photon-Counting Detector CT
    Mergen, Victor
    Sartoretti, Thomas
    Cundari, Giulia
    Serifovic, Medina
    Higashigaito, Kai
    Allmendinger, Thomas
    Schmidt, Bernhard
    Flohr, Thomas
    Manka, Robert
    Eberhard, Matthias
    Alkadhi, Hatem
    INVESTIGATIVE RADIOLOGY, 2023, 58 (11) : 767 - 774
  • [9] Investigating the Small Pixel Effect in Ultra-High Resolution Photon-Counting CT of the Lung
    Huflage, Henner
    Hendel, Robin
    Kunz, Andreas Steven
    Ergun, Sueleyman
    Afat, Saif
    Petri, Nils
    Hartung, Viktor
    Gruschwitz, Philipp
    Bley, Thorsten Alexander
    Grunz, Jan-Peter
    INVESTIGATIVE RADIOLOGY, 2024, 59 (04) : 293 - 297
  • [10] Impact of ultra-high-resolution imaging of the lungs on perceived diagnostic image quality using photon-counting CT
    Valerie Van Ballaer
    Adriana Dubbeldam
    Emanuele Muscogiuri
    Lesley Cockmartin
    Hilde Bosmans
    Walter Coudyzer
    Johan Coolen
    Walter de Wever
    European Radiology, 2024, 34 : 1895 - 1904