Validity and Reliability of New Three-Dimensional Reference Systems for Soft Tissue Analysis Using Non-Ionizing Three-Dimensional Imaging

被引:0
|
作者
Rongo, Roberto [1 ]
D'Anto, Vincenzo [1 ]
Michelotti, Ambrosina [1 ]
Cornelis, Marie A. [2 ]
Cattaneo, Paolo M. [2 ]
机构
[1] Univ Naples Federico II, Sch Orthodont, Dept Neurosci Reprod Sci & Oral Sci, Via Pansini 5, I-80131 Naples, Italy
[2] Univ Melbourne, Fac Med Dent & Hlth Sci, Melbourne Dent Sch, Melbourne, Vic 3010, Australia
来源
APPLIED SCIENCES-BASEL | 2024年 / 14卷 / 12期
关键词
facial scan; CBCT; reference system; orthodontics; CLASS-II; REPRODUCIBILITY; GROWTH; LANDMARKS; VALIDATION; APPLIANCES; CHILDREN;
D O I
10.3390/app14125307
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Featured Application The use of a new and valid reference system for analysis of facial scans might improve the quality of the assessment of orthodontics and orthognathic outcomes. Abstract Background: The aim of this study was to evaluate the accuracy and the repeatability of two reference systems for three-dimensional facial scans (FSs) compared with a reference system based on cone-beam computed tomography (CBCT). Subjects and methods: A total of sixty subjects, thirty growing participants (8-17 years old) and thirty non-growing participants (older than 21 years old), with FSs and full-field-of-view CBCT were included. Two different reference systems on the same FS were constructed. To assess validity, the two reference systems based on FSs were compared with the reference systems built using the CBCT scans. After two weeks, all of the FSs were reassessed to evaluate intra-operator repeatability. Reliability and repeatability were evaluated by means of parametric and non-parametric tests, intra-class correlation, the Dahlberg formula, and Bland-Altman plots (p < 0.05). Results: Both reference systems presented good reliability and showed a small difference with respect to the CBCT-based sagittal plane (Sagittal FS1 = 1.90 +/- 0.98 degrees; Sagittal FS2 = 1.80 +/- 1.13 degrees; p = 0.232). Between them, the two reference systems showed a small difference in the position of the sagittal plane (Sagittal FS1<^>Sagittal FS2 = 1.39 +/- 1.13 degrees). Conclusions: Both reference systems assessed in this study showed good intra-operator repeatability and their use may be suggested as reliable reference systems for FSs.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] A non-ionizing technique for three-dimensional measurement of the lumbar spine
    Koo, Terry K.
    Kwok, Wingchi Edmund
    [J]. JOURNAL OF BIOMECHANICS, 2016, 49 (16) : 4073 - 4079
  • [2] Reproducibility and reliability of three-dimensional soft tissue landmark identification using three- dimensional stereophotogrammetry
    Baysal, Asli
    Sahan, Ahmet Oguz
    Ozturk, Mehmet Ali
    Uysal, Tancan
    [J]. ANGLE ORTHODONTIST, 2016, 86 (06) : 1004 - 1009
  • [3] Three-Dimensional Ultrasound in Soft Tissue Tumor Imaging
    Kneif, Soeren
    Hirche, Christoph
    Mohr, Zarah
    Huenerbein, Michael
    [J]. CURRENT MEDICAL IMAGING REVIEWS, 2009, 5 (04) : 210 - 215
  • [4] Validity and reliability of an iPad with a three-dimensional camera for posture imaging
    Agustsson, A.
    Gislason, M. K.
    Ingvarsson, P.
    Rodby-Bousquet, E.
    Sveinsson, Th
    [J]. GAIT & POSTURE, 2019, 68 : 357 - 362
  • [5] Validity and Reliability of Three-Dimensional Imaging for Measuring the Volume of the Arm
    Erends, Maaike
    van der Aa, Teike
    de Grzymala, Andrzej Piatkowski
    van der Hulst, Rene
    [J]. LYMPHATIC RESEARCH AND BIOLOGY, 2014, 12 (04) : 275 - 281
  • [6] Accuracy of Three-Dimensional Soft Tissue Prediction in Orthognathic Cases Using Dolphin Three-Dimensional Software
    Elshebiny, Tarek
    Morcos, Sherif
    Mohammad, Abdulaziz
    Quereshy, Faisal
    Valiathan, Manish
    [J]. JOURNAL OF CRANIOFACIAL SURGERY, 2019, 30 (02) : 525 - 528
  • [7] Three-dimensional power Doppler: validity and reliability
    Martins, W. P.
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2010, 36 (05) : 530 - 533
  • [8] Three-Dimensional Analysis of the Correlation Between Soft Tissue and Bone of the Lower Face Using Three-Dimensional Facial Laser Scan
    Kim, Seok Hwan
    Shin, Ho Seong
    [J]. JOURNAL OF CRANIOFACIAL SURGERY, 2018, 29 (08) : 2048 - 2054
  • [9] Reliability and validity of three-dimensional fetal brain volumes
    Endres, LK
    Cohen, L
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 2001, 20 (12) : 1265 - 1269