A High Sensitivity CMUT-Based Passive Cavitation Detector for Monitoring Microbubble Dynamics During Focused Ultrasound Interventions

被引:1
|
作者
Zangabad, Reza Pakdaman [1 ]
Lee, Hohyun [1 ]
Zhang, Xitie [2 ]
Kilinc, M. Sait [2 ]
Arvanitis, Costas D. [1 ,3 ]
Degertekin, F. Levent [1 ,2 ]
机构
[1] Georgia Inst Technol, Woodruff Sch Mech Engn, Atlanta, GA 30332 USA
[2] Georgia Inst Technol, Sch Elect & Comp Engn, Atlanta, GA 30332 USA
[3] Georgia Inst Technol, Dept Biomed Engn, Atlanta, GA 30332 USA
关键词
Capacitive micromachined ultrasonic transducer (CMUT); focused ultrasound (FUS); microbubble (MB) activity monitoring; passive cavitation detector (PCD); transimpedance amplifier (TIA); BLOOD-BRAIN-BARRIER; DESIGN; DISRUPTION;
D O I
10.1109/TUFFC.2024.3436918
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Tracking and controlling microbubble (MB) dynamics in the human brain through acoustic emission (AE) monitoring during transcranial focused ultrasound (tFUS) therapy are critical for attaining safe and effective treatments. The low-amplitude MB emissions have harmonic and ultra-harmonic components, necessitating a broad bandwidth and low-noise system for monitoring transcranial MB activity. Capacitive micromachined ultrasonic transducers (CMUTs) offer high sensitivity and low noise over a broad bandwidth, especially when they are tightly integrated with electronics, making them a good candidate technology for monitoring the MB activity through human skull. In this study, we designed a 16-channel analog front-end (AFE) electronics with a low-noise transimpedance amplifier (TIA), a band-gap reference circuit, and an output buffer stage. To assess AFE performance and ability to detect MB AE, we combined it with a commercial CMUT array. The integrated system has 12.3 - 61.25 mV/Pa receive sensitivity with 0.085 - 0.23 mPa/(Hz)(1/2) minimum detectable pressure (MDP) up to 3 MHz for a single element CMUT with 3.78 mm(2) area. Experiments with free MBs in a microfluidic channel demonstrate that our system is able to capture key spectral components of MBs' harmonics when sonicated at clinically relevant frequencies (0.5 MHz) and pressures (250 kPa). Together our results demonstrate that the proposed CMUT system can support the development of novel passive cavitation detectors (PCD) to track MB activity for attaining safe and effective focused ultrasound (FUS) treatments.
引用
收藏
页码:1087 / 1096
页数:10
相关论文
共 7 条
  • [1] Dynamics and control of cavitation during high-intensity focused ultrasound application
    Thomas, CR
    Farny, CH
    Coussios, CC
    Roy, RA
    Holt, RG
    ACOUSTICS RESEARCH LETTERS ONLINE-ARLO, 2005, 6 (03): : 182 - 187
  • [2] Hyperecho as the indicator of tissue necrosis during microbubble-assisted high intensity focused ultrasound: Sensitivity, specificity and predictive value
    Yu, Tinghe
    Xu, Chuanshan
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2008, 34 (08): : 1343 - 1347
  • [3] Optimizing high-intensity focused ultrasound-induced immunogenic cell-death using passive cavitation mapping as a monitoring tool
    Engelen, Yanou
    V. Krysko, Dmitri
    Effimova, Iuliia
    Breckpot, Karine
    Versluis, Michel
    De Smedt, Stefaan
    Lajoinie, Guillaume
    Lentacker, Ine
    JOURNAL OF CONTROLLED RELEASE, 2024, 375 : 389 - 403
  • [4] Differential PI-Based Subharmonic Cavitation Imaging During Pulsed High Intensity Focused Ultrasound Exposures
    Zhong, Hui
    Ma, Xuejin
    Wan, Mingxi
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2017, 7 (05) : 922 - 927
  • [5] The Study of Sub-Harmonic Cavitation Imaging Based on Pulse Inversion Technique for the Monitoring of High Intensity Focused Ultrasound Therapies
    Zhong, Hui
    Ding, Guanhua
    She, Yanmin
    Zong, Yujin
    Wan, Mingxi
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2014, 4 (03) : 410 - 415
  • [6] Real-time monitoring of acoustic cavitation in high intensity focused ultrasound based on phase characteristics of transducer electrical signals
    Liu C.
    Liu L.
    Zhu Q.
    Li Y.
    Shengxue Xuebao/Acta Acustica, 2023, 48 (05): : 1004 - 1011
  • [7] An Integrated and Dynamic Imaging Technique for Simultaneously Monitoring Tissue Damage Formation and Cavitation Bubble Activity During High Intensity Focused Ultrasound (HIFU) Therapy
    Zhong, Hui
    Wan, Mingxi
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2015, 5 (08) : 1729 - 1736