Changes in optic nerve sheath diameter and its correlation with degree of consciousness, pupil diameter, and light reflex in children with central nervous system infection after osmotherapy

被引:0
|
作者
Rizqiamuti, Anggia F. [1 ]
Risan, Nelly A. [1 ]
Solek, Purboyo [1 ]
Hakim, Dzulfikar D. L. [2 ]
Nugraha, Harry G. [3 ]
Hawani, Dewi [1 ]
Dewi, Mia M. [1 ]
Herini, Elisabeth S. [4 ]
机构
[1] Univ Padjadjaran, Hasan Sadikin Gen Hosp, Fac Med, Dept Child Hlth,Neurol Div, Bandung, Indonesia
[2] Univ Padjadjaran, Hasan Sadikin Gen Hosp, Fac Med, Dept Child Hlth,Pediat Emergency & Intens Care Div, Bandung, Indonesia
[3] Univ Padjadjaran, Hasan Sadikin Gen Hosp, Fac Med, Dept Radiol, Bandung, Indonesia
[4] Gadjah Mada Univ, Sardjito Hosp, Fac Med, Dept Child Hlth,Neurol Div, Yogyakarta, Indonesia
来源
FRONTIERS IN PEDIATRICS | 2024年 / 12卷
关键词
CNS infection; increased ICP; osmotherapy; optic nerve sheath diameter; pediatrics; TRANSORBITAL ULTRASOUND MEASUREMENT; INVASIVELY MEASURED ICP; INTRACRANIAL-PRESSURE; SEVERITY; ONSD;
D O I
10.3389/fped.2024.1366968
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Background: High intracranial pressure (ICP) is one of the most common complications of central nervous system (CNS) infection. Failure to control high intracranial pressure results in brain herniation and death. One of the treatments for high ICP involves the administration of osmotherapy in the form of 3% NaCl or 20% mannitol with observation during administration. Observation of ICP during administration of osmotherapy is possible through measurement of optic nerve sheath diameter (ONSD), which could be correlated with degree of consciousness, pupil diameter, and light reflex. Previous studies have not correlated ONSD with degree of consciousness, pupil diameter, and light reflex during the administration of osmotherapy. Purpose: To provide insights of incorporating ONSD measurement as a form of non-invasive bedside method for ICP monitoring by correlating it with degree of consciousness, pupil diameter, and light reflex at several time points. Methods: This study is a prospective cohort study, performed at Dr. Hasan Sadikin General Central Hospital Bandung, Cibabat General Regional Hospital, and General Regional Hospital Bandung Kiwari on children aged 2-18 years with decreased consciousness and CNS infection, from June 2023. Inter-rater reliability was performed with a correlation coefficient of 0.90. Measurement of ONSD, degree of consciousness, pupil diameter, and light reflex simultaneously up to 48 h after initiation of osmotherapy to 30 patients. Correlational analyses were performed using Spearman's rank. Results: Observation for 48 h after administration of osmotherapy showed changes in ONSD. A significant positive correlation was found between ONSD and degree of consciousness (r = 0.621 for the right eye and r = 0.602 for the left eye, p < 0.001). A significant positive correlation was found between ONSD and light reflex (r = 0.801 for the right eye and r = 0.812 for the left eye, p < 0.001). No significant correlation was found with changes of pupil diameter (r = -0.136 for the right eye and r = -0.141 for the left eye, p > 0.05). Conclusion: A significant correlation was found between ONSD and degree of consciousness and light reflex in children aged 2-18 years with CNS infection during administration of osmotherapy.
引用
收藏
页数:11
相关论文
共 4 条
  • [1] Optic nerve sheath diameter and severity of central nervous infection
    Dewi, Anggun Puspita
    Hakim, Dzulfikar Djalil Lukmanul
    Rahayuningsih, Sri Endah
    Risan, Nelly Amalia
    Ghrahani, Raden Reni
    Adrizain, Riyadi
    PAEDIATRICA INDONESIANA, 2023, 63 (05) : 411 - 417
  • [2] Early Detection of Central Nervous System Relapse of Pediatric Leukemia with Measurement of Optic Nerve Sheath Diameter on MRI
    Arpaci, Taner
    Karagun, Barbaros S.
    CURRENT MEDICAL IMAGING REVIEWS, 2019, 15 (02) : 237 - 241
  • [3] The relation of optic nerve sheath diameter (ONSD) and intracranial pressure (ICP) in pediatric neurosurgery practice - Part II: Influence of wakefulness, method of ICP measurement, intra-individual ONSD-ICP correlation and changes after therapy
    Susanne R. Kerscher
    Daniel Schöni
    Felix Neunhoeffer
    Markus Wolff
    Karin Haas-Lude
    Andrea Bevot
    Martin U. Schuhmann
    Child's Nervous System, 2020, 36 : 107 - 115
  • [4] The relation of optic nerve sheath diameter (ONSD) and intracranial pressure (ICP) in pediatric neurosurgery practice - Part II: Influence of wakefulness, method of ICP measurement, intra-individual ONSD-ICP correlation and changes after therapy
    Kerscher, Susanne R.
    Schoeni, Daniel
    Neunhoeffer, Felix
    Wolff, Markus
    Haas-Lude, Karin
    Bevot, Andrea
    Schuhmann, Martin U.
    CHILDS NERVOUS SYSTEM, 2020, 36 (01) : 107 - 115