A Randomized Controlled Trial Comparing the Management of Incomplete Abortion with Oral 600 mg Misoprostol with Manual Vacuum Aspiration (MVA)

被引:0
|
作者
Madhual, Niramaya [1 ]
Tiwari, Heena Dixit [2 ]
Das, Susmita [3 ]
Kamboj, Saloni [4 ]
Thakkar, Smit [5 ]
Kashif, Hala [6 ]
Mahajan, Akriti [7 ]
机构
[1] Padmini Care, Dept Obstet & Gynecol, Cuttack, Odisha, India
[2] Dist Med & Hlth Off, Visakhapatnam, Andhra Pradesh, India
[3] Aster DM Hosp, Dept Obstet & Gynecologist, Dubai, U Arab Emirates
[4] AIIMS, Dept Obstet & Gynaecol, Delhi, India
[5] Shri MP Shah Govt Med Coll, MBBS, Jamnagar, Gujarat, India
[6] Ayaan Inst Med Sci Teaching Hosp & Res Ctr, Hyderabad, Telangana, India
[7] MDS, Oral Med & Radiol, Jammu, Jammu & Kashmir, India
关键词
Abortion; conception; manual vacuum aspiration; misoprostol; pregnancy;
D O I
10.4103/jpbs.jpbs_496_23
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Introduction: In the first trimester, almost one in five identified pregnancies end in spontaneous miscarriage, and another 22% result in induced abortion. After a spontaneous and/or induced abortion, there may be retained products of conception (POC). Because of its relatively poor efficacy and the unpredictability of the time interval until spontaneous evacuation, expectant treatment is not often chosen by healthcare professionals. In view of these facts, the current study's objective was to weigh the effectiveness of MVA and oral misoprostol 600 mg in managing incomplete abortion. Materials and Procedures: The investigation was conducted at the tertiary care center in India. The survey was conducted for one year. Subjects were selected from those attending the department for either spontaneous or induced abortions. A total of 230 women were randomly assigned to receive the interventions of a single dose of oral misoprostol 600 mcg or MVA. They were equally distributed to two groups and observed for the various parameters of success, signs and symptoms, satisfaction, and complications. The obtained values were compared statistically for the significance at <0.05 of P values. Results: Of the 200 subjects (30 lost to follow-up), there was no significant variance in the demographics, clinical outcomes, and complications between the groups. However, the pain, fever, shivering, and satisfaction parameters were statistically variant between the groups. Fever, shivering, and pain were lower for the MISO subjects while satisfaction was reported higher from subjects in MISO group. Conclusion: MISO and MVA are acceptable, safe, and efficient therapies for first-trimester un-complicated incomplete abortion. Nonetheless, misoprostol appears to be a marginally superior option to MVA in terms of accessibility, low therapy costs, reduced pain, and reduced demand for specialized personnel or equipment.
引用
收藏
页码:S290 / S292
页数:3
相关论文
共 50 条
  • [1] A randomized trial of misoprostol compared with manual vacuum aspiration for incomplete abortion
    Weeks, A
    Alia, G
    Blum, J
    Winikoff, B
    Ekwaru, P
    Durocher, J
    Mirembe, F
    OBSTETRICS AND GYNECOLOGY, 2005, 106 (03): : 540 - 547
  • [2] ASSESSMENT OF THE MANUAL VACUUM ASPIRATION (MVA) EQUIPMENT IN THE MANAGEMENT OF INCOMPLETE ABORTION
    KIZZA, APM
    ROGO, KO
    EAST AFRICAN MEDICAL JOURNAL, 1990, 67 (11) : 812 - 822
  • [3] A randomized controlled study comparing 600 versus 1200 μg oral misoprostol for medical management of incomplete abortion
    Ngoc, NTN
    Blum, J
    Durocher, J
    Quan, TTV
    Winikoff, B
    CONTRACEPTION, 2005, 72 (06) : 438 - 442
  • [4] A COMPARISON OF MANUAL VACUUM ASPIRATION (MVA) AND SHARP CURETTAGE IN THE MANAGEMENT OF INCOMPLETE ABORTION
    MAHOMED, K
    HEALY, J
    TANDON, S
    INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 1994, 46 (01) : 27 - 32
  • [5] Comparison of misoprostol and manual vacuum aspiration for the treatment of incomplete abortion
    Bique, C.
    Usta, M.
    Debora, B.
    Chong, E.
    Westheimer, E.
    Winikoff, B.
    INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2007, 98 (03) : 222 - 226
  • [6] A randomized controlled trial of 400-μg sublingual misoprostol versus manual vacuum aspiration for the treatment of incomplete abortion in two Egyptian hospitals
    Dabash, Rasha
    Ramadan, Mohamed Cherine
    Darwish, Emad
    Hassanein, Nevine
    Blum, Jennifer
    Winikoff, Beverly
    INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2010, 111 (02) : 131 - 135
  • [7] Sublingual misoprostol versus manual vacuum aspiration for treatment of incomplete abortion in Nigeria: a randomized control study
    Ani, Vincent Chinedu
    Enebe, Joseph Tochukwu
    Dim, Cyril Chukwudi
    Dim, Ngozi Regina
    Ozumba, Benjamin Chukwuma
    PAN AFRICAN MEDICAL JOURNAL, 2022, 41
  • [8] Paracervical block in incomplete abortion using manual vacuum aspiration:: Randomized clinical trial
    Gómez, PI
    Gaitán, H
    Nova, C
    Paradas, A
    OBSTETRICS AND GYNECOLOGY, 2004, 103 (05): : 943 - 951
  • [9] To Compare the Safety and Efficacy of Manual Vacuum Aspiration with Misoprostol (ST mom) 600mg in Incomplete Miscarriage
    Das, Chandra Madhu
    Sharma, Madhu
    Pardeep, Kusum
    Khurshid, Farkhunda
    JOURNAL OF THE LIAQUAT UNIVERSITY OF MEDICAL AND HEALTH SCIENCES, 2014, 13 (03): : 93 - 96
  • [10] Incomplete miscarriage: a randomized controlled trial comparing oral with vaginal misoprostol for medical evacuation
    Pang, MW
    Lee, TS
    Chung, TKH
    HUMAN REPRODUCTION, 2001, 16 (11) : 2283 - 2287