Over-the-Scope-Clip Iatrogenic Ligation of the Gastroduodenal Artery: A Case Report

被引:0
|
作者
Tran, Loc Truong [1 ]
Dada, Jafar A. [2 ]
Meadows, Jeffery Matthew [2 ]
Willard, Megan Dunnigan [3 ]
机构
[1] CAMC Inst Acad Med, Dept Med, Charleston, WV USA
[2] West Virginia Univ Hosp, Dept Radiol, Morgantown, WV USA
[3] West Virginia Univ, Sch Med, Dept Med, Div Gastroenterol & Hepatol, Morgantown, WV 26506 USA
来源
关键词
Duodenal Ulcer; Embolization; Therapeutic; Endoscopy; Gastrointestinal;
D O I
10.12659/AJCR.943891
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Unusual clinical course Background: The Over -the -Scope -Clip (OTSC) System is a class of endoscopic clips intended to provide improved strength and tissue capture compared to conventional through -the -scope clips. These clips are generally safe and effective in managing many gastrointestinal conditions, with a low overall adverse event rate. Although the OTSC has been used to treat gastrointestinal bleeding and bowel perforations for many years, it often is relegated to second -line therapy and has only recently become a first -line hemostatic therapy for gastrointestinal bleeding. Case Report: Here, we present a unique adverse event of the OTSC causing iatrogenic ligation of the gastroduodenal artery (GDA). A 71 -year -old man presented with 6 months of epigastric abdominal pain and 2 weeks of hematemesis, and was ultimately diagnosed with a bleeding duodenal ulcer. He underwent multiple endoscopic interventions to attempt to control the duodenal ulcer bleeding, including placement of the OTSC on a visible vessel. Soon after OTSC placement, he became hypotensive with recurrent hematochezia, and Interventional Radiology was consulted for endovascular management of the bleeding. Angiography showed the OTSC had been deployed across the midportion of the GDA from the duodenal lumen, effectively ligating the GDA, causing bleeding due to direct vascular injury. This bleeding was ultimately controlled with coil embolization. However, this iatrogenic ligation of the midportion of the GDA by the OTSC significantly complicated endovascular intervention to control the bleeding. Conclusions: As the OTSC device becomes more commonly used in the endoscopy suite, it is important to share potential pitfalls that may be encountered in the clinical setting that impact not only endoscopists and patients, but other specialties as well.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Case Series of Successful Endoscopic Closures of Iatrogenic Perforations Using the Over-The-Scope-Clip (OTSC)
    Chaudhary, Shawn
    Azizi, Sadra
    Nietsch, Hubert
    Sood, Vinay
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2013, 108 : S458 - S458
  • [2] A case report of diverticular bleeding that was handled with using over-the-scope-clip (OTSC)
    Akamine, Eisuke
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2017, 32 : 149 - 149
  • [3] The way to remove an over-the-scope-clip (with video)
    Arezzo, Alberto
    Bullano, Alberto
    Fischer, Harald
    Morino, Mario
    GASTROINTESTINAL ENDOSCOPY, 2013, 77 (06) : 974 - 975
  • [4] Small intestine grasped by over-the-scope-clip during attempt to close an iatrogenic colonic perforation
    Loske, Gunnar
    Schorsch, Tobias
    Daseking, Emmerich
    Martens, Eckard
    Mueller, Christian Theodor
    ENDOSCOPY, 2016, 48 : E26 - E27
  • [5] Over-the-scope clip to the rescue of a bleeding gastroduodenal artery pseudoaneurysm
    El Douaihy, Youssef
    Kesavan, Mayuratha
    Deeb, Liliane
    Abergel, Jeffrey
    Andrawes, Sherif
    GASTROINTESTINAL ENDOSCOPY, 2016, 84 (05) : 854 - 855
  • [6] Over-the-scope-clip applications for perforated peptic ulcer
    Wei, Jing-Jing
    Xie, Xue-Ping
    Lian, Ting-Ting
    Yang, Zhi-Yong
    Pan, Yu-Feng
    Lin, Zhen-Lv
    Zheng, Guang-Wei
    Zhuang, Ze-Hao
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2019, 33 (12): : 4122 - 4127
  • [7] Over-the-scope-clip: Endoscopic treatment of Boerhaave syndrome
    Nunez Rodriguez, Ma Henar
    Sanchez Martin, Fatima
    Najera, Rodrigo
    Diez Redondo, Pilar
    GASTROENTEROLOGIA Y HEPATOLOGIA, 2019, 42 (09): : 564 - 565
  • [8] The way to remove an over-the-scope-clip (with video) Response
    Neumann, Helmut
    Wildner, Dane
    Tontini, Gian E.
    Grauer, Martin
    Neurath, Markus F.
    Moenkemueller, Klaus
    GASTROINTESTINAL ENDOSCOPY, 2013, 77 (06) : 975 - 976
  • [9] Endoscopic Closure of a Intraoperatively Perforated Duodenal Diverticulum Using an "Over-the-Scope-Clip" (OTSC) - A Case Report
    Wedi, E.
    Menke, D.
    Hochberger, J.
    ENDOSKOPIE HEUTE, 2010, 23 (03) : 224 - 226
  • [10] Endoscopic removal of an over-the-scope-clip ("bear claw")
    Moenkemueller, Klaus
    Toshniwal, Jay
    Zabielski, Marzena