Seismic performance of FRP-repaired RC piers after blast loading

被引:0
|
作者
Cheng, Y. H. [1 ]
Xu, J. P. [1 ]
Wu, H. [1 ]
机构
[1] Tongji Univ, Coll Civil Engn, Shanghai 200092, Peoples R China
关键词
RC pier; Contact explosion; FRP repair; Seismic performance; Numerical simulation;
D O I
10.1016/j.engstruct.2024.118989
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Aiming to evaluate the effectiveness of fiber-reinforced polymer (FRP) repair on the seismic performance of blast- damaged reinforced concrete (RC) piers, the field test and numerical simulation were conducted. Firstly, a successive field explosion test, carbon FRP (CFRP) repair, and lateral cyclic loading test were performed on two 1/2-scale RC pier specimens. The test data including the incident overpressure-time histories of blast wave, damage profiles and lateral force-displacement relationships of pier specimens, etc. were comprehensively recorded and discussed. By comparing with the previous blast-damaged pier specimen, the negative maximum force and ductility of CFRP-repaired pier were increased by 97 % and 44.9 % after 1.0 kg TNT explosion, respectively. Then, an integrated numerical simulation approach based on explicit-implicit switching and full restart algorithms was proposed and validated in predicting the dynamic and quasi-static behaviors of RC piers under successive blast loading, CFRP repair, and lateral cyclic loading. Finally, a prototype RC pier was designed and the suicide vest bomb (TNT equivalence of 9 kg) specified by the Federal Emergency Management Agency was selected as the threat of contact explosion. The influences of FRP type, repair height, and number of FRP layer on restoring the seismic performance of the blast-damaged pier were further discussed. It indicates that, (i) CFRP is more effective than glass FRP and aramid FRP; (ii) increasing the repair height could not significantly improve the seismic performance of pier; (iii) the number of FRP layer has significant effect, e.g., the positive and negative maximum forces after 4-layer CFRP repair are improved by 9.4 % and 45.3 % compared to the unrepaired pier, respectively. The present study could provide a helpful reference for assessing the FRP repair effectiveness on the seismic performance of blast-damaged RC bridge piers.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Seismic performance of hollow-bridge piers repaired by FRP
    Cheng, CT
    Yang, JC
    Yeh, YK
    [J]. FRP COMPOSITES IN CIVIL ENGINEERING, VOLS I AND II, PROCEEDINGS, 2001, : 859 - 867
  • [3] FE modelling of FRP-repaired RC plane stress elements
    Khomwan, N
    Foster, SJ
    [J]. FIBRE-REINFORCEMENT POLYMER: REINFORCEMENT FOR CONCRETE STRUCTURES, VOLS 1 AND 2, PROCEEDINGS, 2003, : 1177 - 1186
  • [4] Postrepair fatique performance of FRP-repaired corroded RC beams: Experimental and analytical investigation
    Masoud, S
    Soudki, K
    Topper, T
    [J]. JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2005, 9 (05) : 441 - 449
  • [5] ASCE 41 Seismic Assessment of FRP-Repaired Concrete Columns
    Harries, Kent A.
    [J]. JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2021, 25 (02)
  • [6] Load-bearing capacity of corroded, patched and FRP-repaired RC beams
    Malumbela, Goitseone
    Moyo, Pilate
    Alexander, Mark
    [J]. MAGAZINE OF CONCRETE RESEARCH, 2011, 63 (11) : 797 - 812
  • [7] FE Modeling of FRP-Repaired Planar Concrete Elements Subjected to Monotonic and Cyclic Loading
    Khomwan, Nantawat
    Foster, Stephen J.
    Smith, Scott T.
    [J]. JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2010, 14 (06) : 720 - 729
  • [8] Experiment on seismic performance of RC piers
    Sun, Z
    Yan, GP
    Zhong, TY
    [J]. TIVC'2001: INTERNATIONAL SYMPOSIUM ON TRAFIC INDUCED VIBRATIONS & CONTROLS, 2001, : 143 - 153
  • [9] Seismic performance of repaired RC columns
    Youm, KS
    Lee, HE
    Choi, S
    [J]. MAGAZINE OF CONCRETE RESEARCH, 2006, 58 (05) : 267 - 276
  • [10] Seismic performance of repaired hollow-bridge piers
    Cheng, CT
    Yang, JC
    Yeh, YK
    Chen, SE
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2003, 17 (05) : 339 - 351