A Simple Power Loss Evaluation Method for High-Frequency Transformers Based on Surface Temperature Measurement Within Wide Operation Range

被引:1
|
作者
Yi, Zheyuan [1 ]
Liu, Zengyang [1 ]
Sun, Kai [1 ]
Su, Bowen [1 ]
机构
[1] Tsinghua Univ, Dept Elect Engn, State Key Lab Power Syst Operat & Control, Beijing, Peoples R China
关键词
High-frequency transformers; loss evaluation; surface temperature; thermal network; calibration; FERRITE;
D O I
10.1109/APEC48139.2024.10509136
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Power loss measurement and evaluation form the foundation of loss modeling and optimization. This paper proposes a method for evaluating power loss in high-frequency (HF) transformers operating under forced air-cooling conditions, simply based on surface temperature measurement with a thermal camera. A direct correlation is established between power loss and surface temperature, utilizing a simplified thermal network. This method enables the measurement of both total loss and individual core loss and winding loss directly for HF transformers operating within the whole range of normal working conditions. Simulations are conducted to validate the practicality and accuracy of the proposed method. Experiments are carried out on a HF transformer prototype, following the proposed loss evaluation process, validating the accuracy of the evaluated power loss within wide operation range in loaded tests.
引用
收藏
页码:402 / 409
页数:8
相关论文
共 50 条
  • [1] A Simple Power Loss Evaluation Method for High-Frequency Transformers Based on Surface Temperature Measurement Within Wide Operation Range
    Yi, Zheyuan
    Liu, Zengyang
    Sun, Kai
    Su, Bowen
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2024, 12 (06) : 5437 - 5451
  • [2] Core Loss Evaluation of High-Frequency Transformers in High-Power DC-DC Converters
    Bahmani, Amin
    2018 THIRTEENTH INTERNATIONAL CONFERENCE ON ECOLOGICAL VEHICLES AND RENEWABLE ENERGIES (EVER), 2018,
  • [3] High-frequency electric field intensity measurement based on frequency shift with high gain and wide frequency range
    Lin, Feihong
    Wang, Xihao
    Tang, Mingwei
    Zhang, Jiqiang
    Wang, Lining
    Liu, Xu
    Yang, Qing
    OPTICS COMMUNICATIONS, 2023, 545
  • [4] A METHOD FOR WIDE FREQUENCY-RANGE MODELING OF POWER TRANSFORMERS AND ROTATING MACHINES
    SOYSAL, AO
    KAMWA, I
    GRONDIN, R
    IEEE TRANSACTIONS ON POWER DELIVERY, 1993, 8 (04) : 1802 - 1810
  • [5] High-Frequency Transformer Loss Measurement and Modeling: A DC Loss Method
    Yang, Deqiu
    Wang, Binhao
    Shao, Shuai
    Zhang, Junming
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2025, 40 (04) : 5635 - 5645
  • [6] A Measurement Method of Winding Loss for High-Frequency Transformer Based on Auxiliary Winding
    Wang T.
    Luo R.
    Wen J.
    Zhang M.
    Tian J.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2022, 37 (10): : 2622 - 2630and2655
  • [7] Measurement and Evaluation Method based on Under-sampling of High-Frequency Wide-Band Radio Signal
    Kanno, Shouta
    Imaike, Takeshi
    Otani, Akihito
    2019 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2019, : 868 - 873
  • [8] MEASUREMENT OF LOSSES IN TOROIDAL CORES OF LOW-POWER TRANSFORMERS OVER A WIDE FREQUENCY RANGE
    ZVENIGOR.AI
    LEVITSKA.NV
    MEASUREMENT TECHNIQUES, 1973, 16 (09) : 1357 - 1359
  • [9] Design Method of Inductor-integrated High-power High-frequency Transformers
    CHEN Bin
    LI Lin
    ZHAO Zhibin
    ZHANG Xiwei
    ZHANG Pengning
    中国电机工程学报, 2018, 38 (05) : 1625 - 1625
  • [10] A Load Test Method Using Two Power Supplies for High-Frequency Transformers
    Orikawa, Koji
    Nishikawa, Shogo
    Ogasawara, Satoshi
    2022 INTERNATIONAL POWER ELECTRONICS CONFERENCE (IPEC-HIMEJI 2022- ECCE ASIA), 2022, : 2591 - 2598