Effect of graft sizing in valve-sparing aortic root replacement for bicuspid aortic valve: The Goldilocks ratio

被引:1
|
作者
Choi, Perry S. [1 ]
Sharir, Amit [1 ]
Ono, Yoshikazu [1 ]
Shibata, Masafumi [1 ]
Kaiser, Alexander D. [1 ,2 ]
Zhu, Yuanjia
Marsden, Alison L. [2 ]
Woo, Y. Joseph [1 ]
Ma, Michael R. [1 ]
Kim, Joon Bum [1 ,3 ]
机构
[1] Stanford Univ, Dept Cardiothorac Surg, Palo Alto, CA USA
[2] Stanford Univ, Dept Pediat, Div Pediat Cardiol, Palo Alto, CA USA
[3] Univ Ulsan, Asan Med Ctr, Dept Thorac & Cardiovasc Surg, Coll Med, 88 Olympic Ro 43 Gil, Seoul 05505, South Korea
关键词
CONDUIT CONFIGURATIONS;
D O I
10.1016/j.xjtc.2024.03.025
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To investigate the effect of graft sizing on valve performance in valvesparing aortic root replacement for bicuspid aortic valve. Methods: In addition to a diseased control model, 3 representative groups - freeedge length to aortic/graft diameter (FELAD) ratio < 1.3, 1.5 to 1.64, and > 1.7 - were replicated in explanted porcine aortic roots (n = 3) using straight grafts sized respective to the native free -edge length. They were run on a validated ex vivo univentricular system under physiological parameters for 20 cycles. All groups were tested within the same aortic root to minimize inter -root differences. Outcomes included transvalvular gradient, regurgitation fraction, and ori fi ce area. Linear mixed effects model and pairwise comparisons were employed to compare outcomes across groups. Results: The diseased control had mean transvalvular gradient 10.9 +/- 6.30 mm Hg, regurgitation fraction 32.5 +/- 4.91 % , and ori fi ce area 1.52 +/- 0.12 cm 2 . In ex vivo analysis, all repair groups had improved regurgitation compared with control ( P < .001). FELAD < 1.3 had the greatest amount of regurgitation among the repair groups ( P < .001) and 1.5-1.64 the least ( P < .001). FELAD < 1.3 and > 1.7 exhibited greater mean gradient compared with both control and 1.5 to 1.64 ( P < .001). Among the repair groups, 1.5 to 1.64 had the largest ori fi ce area, and > 1.7 the smallest ( P < .001). Conclusions: For a symmetric bicuspid aortic valve, performance after valvesparing aortic root replacement shows a bimodal distribution across graft size. As the FELAD ratio departs from 1.5 to 1.64 in either direction, signi fi cant increases in transvalvular gradient are observed. FELAD < 1.3 may also result in suboptimal improvement of baseline regurgitation. (JTCVS Techniques 2024;25:1-7)
引用
收藏
页码:1 / 7
页数:7
相关论文
共 50 条
  • [1] Valve-sparing aortic root replacement and the bicuspid aortic valve: The details matter
    Girardi, Leonard N.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2018, 155 (04): : 1412 - 1413
  • [2] Valve-sparing aortic root replacement in a bicuspid aortic valve with papillary fibroelastoma
    Kondov, Stoyan
    Kari, Fabian Alexander
    Czerny, Martin
    Siepe, Matthias
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2017, 25 (04) : 671 - 673
  • [3] Valve-sparing aortic root replacement in bicuspid aortic valve: as good as in tricuspid?
    Holubec, Tomas
    Van Linden, Arnaud
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2023, 63 (04)
  • [4] Bicuspid aortic valve durability with valve-sparing aortic root replacement: comparison to tricuspid valve
    Levine, Dov
    Patel, Parth
    Zhao, Yanling
    Childress, Patra
    Chung, Megan
    Leshnower, Bradley G.
    Kurlansky, Paul
    Smith, Craig R.
    Chen, Edward P.
    Takayama, Hiroo
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2023, 63 (04)
  • [5] Valve-Sparing Aortic Root Replacement and Tricuspidization in a Patient with an Asymmetric Bicuspid Aortic Valve
    Konstantinov, Igor E.
    Saxena, Pankaj
    TEXAS HEART INSTITUTE JOURNAL, 2010, 37 (01) : 79 - 81
  • [6] Valve-sparing aortic replacement - is preservation of a bicuspid aortic valve justified?
    Aicher, D
    Nikoloudakis, N
    Langer, F
    Schaefers, HJ
    Graeter, T
    EUROPEAN HEART JOURNAL, 2001, 22 : 368 - 368
  • [7] Valve-sparing aortic root replacement in bicuspid aortic valves:: A reasonable option?
    Aicher, D
    Langer, F
    Kissinger, A
    Lausberg, H
    Fries, R
    Schäfers, HJ
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2004, 128 (05): : 662 - 668
  • [8] Valve-sparing Aortic Root Replacement
    Shimizu, Hideyuki
    Yozu, Ryohei
    ANNALS OF THORACIC AND CARDIOVASCULAR SURGERY, 2011, 17 (04) : 330 - 336
  • [9] Valve-sparing aortic root replacement
    Sin, YK
    Pillai, RG
    JOURNAL OF CARDIAC SURGERY, 2000, 15 (06) : 424 - 427
  • [10] Valve-sparing aortic root replacement
    Koolbergen, David R.
    Manshanden, Johan S. J.
    Bouma, Berto J.
    Blom, Nico A.
    Mulder, Barbara J. M.
    de Mol, Bas A. J. M.
    Hazekamp, Mark G.
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2015, 47 (02) : 348 - 354