Accuracy of surgical guides manufactured with four different 3D printers. A comparative in vitro study

被引:3
|
作者
Moron-Conejo, Belen [1 ]
Berrendero, Santiago [1 ]
Salido, Maria Paz [1 ]
Zarauz, Cristina [2 ]
Pradies, Guillermo [1 ]
机构
[1] Univ Complutense Madrid, Fac Dent, Dept Conservat & Prosthet Dent, Plaza Ramon & Cajal S-N, Madrid 28040, Spain
[2] Univ Geneva, Div Fixed Prosthodont & Biomat, Clin Dent Med, Rue Michel Servet 1, CH-1211 Geneva 4, Switzerland
关键词
3D printing; Accuracy; Implantology; Surgical guide; Guided implant surgery; Stereolithography; IMPLANT PLACEMENT; SURGERY; UPDATE;
D O I
10.1016/j.jdent.2024.105226
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The aim of this study was to assess the accuracy of surgical guides manufactured with four different 3D printers.. Methods: Forty-eight surgical guides (BlueSky Plan, BlueSky Bio) were produced using four different 3D printers, with strict adherence to each manufacturer's instructions. The printers used were three digital light processing (DLP) printers (SolFlex170, VC; Nextdent5100, ND, and D30+Rapidshape, RS) and one stereolithographic (SLA) printer (Formlabs3B+, FL). The study evaluated the trueness and precision of the overall surface, the region of interest (RoI) (occlusal and guide zone), the repeatability in several batches, and the guide hole's diameter and xyz axes. The printed guides were digitized and compared with the CAD design control specimen (Control X, Geomagic). Descriptive statistics and Kruskal-Wallis tests with post-hoc Mann-Whitney tests were performed (alpha=0.05). Results: Differences in trueness and precision were found between groups in the overall zone and RoI (p = 0.00). The ND group demonstrated the highest repeatability. Only the RS group exhibited a comparable guide hole diameter to the master specimen (5.27 +/- 2.12 mm; p = 0.104). No statistical differences were observed between groups in the x and z axes. However, in the y-axis, the VC group displayed statistically significant differences (p = 0.01). Conclusions: The results showed that the DLP groups had better overall accuracy, while the SLA group had the best results in the RoI. The manufacturer's workflows demonstrated a high reproducibility between batches in the RoI. The RS group had values most similar values to the guide hole diameter of the master specimen, with minimal deviations in guide hole orientation. Clinical significance: Implant position can be affected by the accuracy of the 3D printed surgical guide. Therefore, it is critical to analyze the final dimensions and the direction of the guide hole using available printing technologies.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Accuracy of 3D printed polymers intended for models and surgical guides printed with two different 3D printers
    Johansson, Camilla
    Dibes, Jasmin
    Rodriguez, Luis Emilio Lopez
    Papia, Evaggelia
    DENTAL MATERIALS JOURNAL, 2021, 40 (02) : 339 - 347
  • [2] Accuracy of commercial 3D printers for the fabrication of surgical guides in dental implantology
    l'Alzit, Francois Rouze
    Cade, Romain
    Naveau, Adrien
    Babilotte, Joanna
    Meglioli, Matteo
    Catros, Sylvain
    JOURNAL OF DENTISTRY, 2022, 117
  • [3] Accuracy of 6 Desktop 3D Printers in Dentistry: A Comparative In Vitro Study
    Mangano, Francesco G.
    Admakin, Oleg
    Bonacina, Matteo
    Biaggini, Francesco
    Farronato, Davide
    Lerner, Henriette
    EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2020, 28 (02): : 75 - 85
  • [4] Comparison of the accuracy of implants placed with CAD-CAM surgical templates manufactured with various 3D printers: An in vitro study
    Herschdorfer, Laura
    Negreiros, William Matthew
    Gallucci, German O.
    Hamilton, Adam
    JOURNAL OF PROSTHETIC DENTISTRY, 2021, 125 (06): : 905 - 910
  • [5] Accuracy of immediately placed implants using surgical guides from different 3-dimensional printers: An in vitro study
    Pitman, Jeremy
    Cosyn, Jan
    Christiaens, Veronique
    Younes, Faris
    de Bruyckere, Thomas
    Vervaeke, Stijn
    Glibert, Maarten
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2024, 26 (05) : 922 - 929
  • [6] Accuracy of surgical guides from 2 different desktop 3D printers for computed tomography-guided surgery
    Gjelvold, Bjorn
    Mahmood, Deyar Jallal Hadi
    Wennerberg, Ann
    JOURNAL OF PROSTHETIC DENTISTRY, 2019, 121 (03): : 498 - 503
  • [7] DETAILED GUIDE TO OWN ASSEMBLY OF 3D PRINTERS.
    Pereira, Mateus, V
    Quero, Reverson F.
    de Jesus, Dosil P.
    Bonacin, Juliano A.
    QUIMICA NOVA, 2023, 46 (08): : 822 - 827
  • [8] Accuracy and precision of 3D-printed implant surgical guides with different implant systems: An in vitro study
    Yeung, Matthew
    Abdulmajeed, Aous
    Carrico, Caroline K.
    Deeb, George R.
    Bencharit, Sompop
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (06): : 821 - 828
  • [9] Accuracy of Dental and Industrial 3D Printers
    Anadioti, Eva
    Kane, Brittany
    Zhang, Yu
    Bergler, Michael
    Mante, Francis
    Blatz, Markus B.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 : 30 - 37
  • [10] NEW MATERIALS FOR CONSTRUCTION WITH 3D PRINTERS, COMPARATIVE STUDY
    Valiente Lopez, M.
    Moyano Sanz, S.
    Sanz Contreras, M. C.
    12TH INTERNATIONAL TECHNOLOGY, EDUCATION AND DEVELOPMENT CONFERENCE (INTED), 2018, : 6607 - 6616