I-125 eye-plaque seed economics: To re-use or to not re-use? A single institutional cost savings analysis of re-using I-125 radioactive seeds for eye-Plaque brachytherapy

被引:0
|
作者
Cappelli, Louis [1 ]
Emrich, Jacqueline [1 ,2 ,3 ]
Komarnicky-Kocher, Lydia [1 ]
Vinogradskiy, Yevgeniy [3 ]
Mourtada, Firas [3 ]
机构
[1] Thomas Jefferson Univ, Dept Radiat Oncol, Philadelphia, PA 19147 USA
[2] Wills Eye Hosp & Res Inst, Dept Med Phys, Philadelphia, PA USA
[3] Thomas Jefferson Univ, Dept Med Phys, Philadelphia, PA 19147 USA
关键词
Cost saving; Iodine-125 radioactive seed; Brachytherapy; Eye; -plaque; Cost analysis; COLLABORATIVE OCULAR MELANOMA; COMS RANDOMIZED-TRIAL; CHOROIDAL MELANOMA; UVEAL MELANOMA; PD-103;
D O I
10.1016/j.brachy.2024.04.001
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
INTRODUCTION: Iodine-125 (I-125) seeds, commonly used in low-dose rate brachytherapy for ocular malignancies, are often discarded after a single use. This study examines the potential cost savings at an institution with high ocular melanoma referrals, by re-using I-125 seeds for eye-plaque brachytherapy. METHODS: In this single-institutional retrospective analysis, data was collected from I-125 seed orders from 8/2019 through 10/2022. Information including number of seeds ordered per lot, number of plaques built per lot, and number of seeds used per lot were collected. Cost per lot of seed was assumed to be the current cost from the most recent lot of 35 seeds. RESULTS: During the study, 72 I-125 seed lots were ordered bi-weekly, with a median of 35 seeds per lot (Range: 15-35). Each seed was used on average 2.26 times prior to being discarded. The average duration of each seed lot used was 62.2 days (Range: 21-126). Each seed lot contributed to the construction of an average of 8.4 eye plaques (Range: 2-20). With seed recycling, 2,475 seeds were used to construct 608 eye-plaques. Without re-using practice this would require 5,694 seeds. This resulted in a percentage cost savings of 56.5%, with a total seed cost reduction of $344,884, or $559 per eye-plaque on average. CONCLUSION: This is the first study to evaluate cost savings relative to re-using I-125 seeds for eye plaques. The data demonstrates how an institution can decrease costs associated with I-125 radiation seeds used for eye-plaque brachytherapy by re-using them. (c) 2024 American Brachytherapy Society. Published by Elsevier Inc. All rights are reserved, including those for text and data mining, AI training, and similar technologies.
引用
收藏
页码:463 / 469
页数:7
相关论文
共 12 条
  • [1] Re-treatment of locally recurrent uveal melanoma with repeat eye plaque I-125 brachytherapy: A single institution experience
    Tran, Kevin
    Schefler, Amy C.
    Chevli, Neil
    Hasegawa, Naomi
    Ivey, Forrest
    Olek, Devin
    Bretana, Maria E.
    Pino, Ramiro
    Butler, Edward Brian
    Teh, Bin S.
    [J]. BRACHYTHERAPY, 2024, 23 (05) : 604 - 609
  • [2] Dosimetric validation of the Theragenics AgX-100® I-125 seed for ROPES eye plaque brachytherapy
    Claire Pagulayan
    Soo Min Heng
    Stephanie Corde
    [J]. Australasian Physical & Engineering Sciences in Medicine, 2019, 42 : 599 - 609
  • [3] Dosimetric validation of the Theragenics AgX-100® I-125 seed for ROPES eye plaque brachytherapy
    Pagulayan, Claire
    Heng, Soo Min
    Corde, Stephanie
    [J]. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2019, 42 (02) : 599 - 609
  • [4] Development of GATE Monte Carlo Code for Simulation and Dosimetry of New I-125 Seeds in Eye Plaque Brachytherapy
    Payvand Taherparvar
    Zeinab Fardi
    [J]. Nuclear Medicine and Molecular Imaging, 2021, 55 : 86 - 95
  • [5] Development of GATE Monte Carlo Code for Simulation and Dosimetry of New I-125 Seeds in Eye Plaque Brachytherapy
    Taherparvar, Payvand
    Fardi, Zeinab
    [J]. NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 55 (02) : 86 - 95
  • [6] A THIN I-125 SEED EYE PLAQUE TO TREAT INTRAOCULAR TUMORS USING AN ACRYLIC INSERT TO PRECISELY POSITION THE SOURCES
    KAROLIS, C
    FROST, RB
    BILLSON, FA
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 18 (05): : 1209 - 1213
  • [7] Shortcomings in published brachytherapy source parameters for accurate dose calculation for an eye plaque implant with I-125 or Pd-103 seeds
    Awan, S.
    Meigooni, A.
    Dini, S.
    Chen, Y.
    Khan, F.
    Cole, J.
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 2488 - 2489
  • [8] Episcleral plaque brachytherapy using 'BARC I-125 Ocu-Prosta seeds' in the treatment of intraocular tumors: A single-institution experience in India
    Shah, Parag K.
    Narendran, V.
    Selvaraj, U.
    Guhan, P.
    Saxena, Sanjay K.
    Dash, Ashutosh
    Astrahan, Melvin
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2012, 60 (04) : 289 - 295
  • [9] Pilot Study On Critical Structure Dosing for Ocular Melanoma Radiation Techniques: An Analysis of I-125 Brachytherapy Plaque and Dedicated Proton Eye Beamline Treatment Planning Dosimetry
    Scholey, J.
    Weinberg, V.
    Daftari, I.
    Mishra, K.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E594 - E595
  • [10] Novel application of 3D printing in brachytherapy using MED610 3D printed insert for I-125 ROPES eye plaque
    Sim, L.
    [J]. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2016, 39 (04) : 863 - 870