Effectiveness and safety of MR-guided focused ultrasound thalamotomy in patients with essential tremor and low skull density ratio: a study of 101 cases

被引:2
|
作者
Hino, Sakae [1 ,2 ]
Maki, Futaba [1 ,2 ]
Yamaguchi, Toshio [3 ,4 ]
Kaburagi, Mayumi [1 ,2 ]
Nakano, Masayuki [5 ]
Iwamuro, Hirokazu [6 ]
Takasaki, Masahito [7 ]
Iijima, Ken [8 ]
Kanouchi, Masashi [9 ]
Sasanuma, Jinichi [5 ]
Watanabe, Kazuo [5 ]
Hasegawa, Yasuhiro [1 ,2 ]
Yamano, Yoshihisa [1 ,2 ]
机构
[1] St Marianna Univ, Dept Neurol, Sch Med, Kawasaki, Kanagawa, Japan
[2] Shin Yurigaoka Gen Hosp, Dept Hematol, Kawasaki, Kanagawa, Japan
[3] Int Acad Focused Ultrasound Therapy, Yokohama, Kanagawa, Japan
[4] Shin Yurigaoka Gen Hosp, Res Inst Diagnost Radiol, Kawasaki, Kanagawa, Japan
[5] Shin Yurigaoka Gen Hosp, Dept Neurosurg, Kawasaki, Kanagawa, Japan
[6] Juntendo Univ, Dept Neurosurg, Tokyo, Japan
[7] Shin Yurigaoka Gen Hosp, Dept Anesthesiol, Kawasaki, Kanagawa, Japan
[8] Saitama Sekishinkai Hosp, Dept Radiol, Saitama, Japan
[9] Shin Yurigaoka Gen Hosp, Dept Radiol, Kawasaki, Kanagawa, Japan
基金
日本学术振兴会;
关键词
magnetic resonance-guided focused ultrasound; thalamotomy; essential tremor; low skull density ratio; functional neurosurgery; EFFICIENCY;
D O I
10.3171/2023.11.JNS231799
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE The objective was to investigate the effectiveness and safety of MR-guided focused ultrasound (MRgFUS) treatment in patients with essential tremor, particularly those with low skull density ratio (SDR) and including those with very low SDR, and to identify the factors influencing treatment effectiveness and to provide insights into therapeutic ap- proaches for patients with lower SDR. METHODS Real-world data from 101 patients who underwent MRgFUS between July 2019 and March 2022 at a single institution were analyzed. Tremor severity was assessed using the Fahn-Tolosa-Marin Clinical Rating Scale for Tremor (CRST). The patients were categorized into quartile groups based on their mean SDR, and the characteristics, treatment effectiveness, treatment parameters, and adverse events were evaluated among these subgroups. RESULTS Patients were classified into 4 quartiles based on the mean SDR: quartile 1 (Q1) (SDR 0.26-0.37), Q2 (SDR 0.38-0.42), Q3 (SDR 0.43-0.49), and Q4 (SDR 0.50-0.75). MRgFUS significantly improved total CRST and tremor score across all SDR subgroups. Additionally, there were no significant differences in the improvement rates among the 4 subgroups. Analysis of the treatment parameters revealed that lower mean SDR was associated with lower target maximum temperature and smaller coagulation volume after focused ultrasound (FUS). Regarding adverse events, headache and nausea during FUS and facial and head edema on the day after surgery were more frequent in the Q1 subgroup (very low-SDR group). In contrast, numbness was more common in the Q4 subgroup. However, all these adverse events had resolved by the 3-month follow-up except numbness. CONCLUSIONS This study suggested that MRgFUS is effective and safe for patients with medication-resistant essential tremor, including those with very low mean SDR. However, the very low-SDR group had insufficient temperature elevation at the target site compared with the high-SDR group, suggesting the need for a different strategy. Notably, with careful adjustments and considerations, positive outcomes can still be achieved in patients with very low SDR. Therefore, very low SDR should not be considered an absolute exclusion criterion because it is expected to increase the number of patients who benefit from MRgFUS.
引用
收藏
页码:212 / 220
页数:9
相关论文
共 50 条
  • [1] The Distribution of Skull Score and Skull Density Ratio in Tremor Patients for MR-Guided Focused Ultrasound Thalamotomy
    Tsai, Kevin Wen-Kai
    Chen, Jui-Cheng
    Lai, Hui-Chin
    Chang, Wei-Chieh
    Taira, Takaomi
    Chang, Jin Woo
    Wei, Cheng-Yu
    FRONTIERS IN NEUROSCIENCE, 2021, 15
  • [2] Safety of Staged bilateral MR-guided Focused Ultrasound Thalamotomy for Essential Tremor
    Kaplitt, M.
    Sarva, H.
    Krishna, V.
    Eisenberg, H. M.
    Elias, W. J.
    Ghanouni, P.
    Baltuch, G. H.
    Rezai, A.
    Halpern, C.
    Dalm, B.
    Fishman, P.
    Buch, V.
    Moosa, S.
    Murray, A. M.
    MOVEMENT DISORDERS, 2024, 39 : S512 - S513
  • [3] The Effect of Skull Density Ratio on Tremor Improvement and Rates of Adverse Events of MR-Guided Focused Ultrasound Thalamotomy
    D'Souza, Marissa
    Chen, Kevin
    Dayan, Mor
    Rosenberg, Jarrett
    Pauly, Kimberly Butts
    Halpern, Casey
    Ghanouni, Pejman
    JOURNAL OF NEUROSURGERY, 2019, 131 (01)
  • [4] MR-guided focused ultrasound thalamotomy for essential tremor: a proof-of-concept study
    Lipsman, Nir
    Schwartz, Michael L.
    Huang, Yuexi
    Lee, Liesly
    Sankar, Tejas
    Chapman, Martin
    Hynynen, Kullervo
    Lozano, Andres M.
    LANCET NEUROLOGY, 2013, 12 (05): : 462 - 468
  • [5] MR-guided Focused Ultrasound Thalamotomy for Essential Tremor - one year results
    Elias, W. Jeff
    Huss, Diane
    Voss, Tiffini
    Loomba, Johanna
    Khaled, Mohamad
    Zadicario, Eyal
    Frysinger, Robert
    Sperling, Scott
    Wylie, Scott
    Druzgal, Jason
    Shah, Binit
    Harrison, Madaline
    Wintermark, Max
    STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2013, 91 : 2 - 2
  • [6] Minimum and early high-energy sonication protocol of MR-guided focused ultrasound thalamotomy for low-skull density ratio patients with essential tremor and Parkinson's disease
    Nishida, Namiko
    Sugita, Yoshito
    Sawada, Masahiro
    Ishimori, Takayoshi
    Taruno, Yosuke
    Otsuki, Kazuya
    Motoie, Ryota
    Kitamura, Kazushi
    Yoshizaki, Wataru
    Kasashima, Kazuhiro
    Sugiyama, Jumpei
    Yamashita, Masahito
    Hanyu, Takashi
    Takahashi, Makio
    Kaneko, Satoshi
    Toda, Hiroki
    NEUROSURGICAL FOCUS, 2024, 57 (03)
  • [7] Assessing the impact of MR-guided focused ultrasound thalamotomy on brain activity and connectivity in patients with essential tremor
    Lu, Haoxuan
    Lin, Jiaji
    Xiong, Yongqin
    Deng, Linlin
    Wang, Xiaoyu
    Zhang, Dekang
    Bian, Xiangbing
    Zhou, Jiayou
    Pan, Longsheng
    Lou, Xin
    NEUROSURGICAL FOCUS, 2022, 53 (06)
  • [8] Impact of target depth on safety and efficacy outcomes in MR-guided focused ultrasound thalamotomy for tremor patients
    Buchele, Fabian
    Mahendran, Sujitha
    Uhl, Mechtild
    Freudinger, Carola
    Maric, Angelina
    Heeb, Nicole Sarangi
    Oertel, Markus Florian
    Baumann, Christian Rainer
    Stieglitz, Lennart Henning
    JOURNAL OF NEUROSURGERY, 2024, 140 (05) : 1451 - 1458
  • [9] Magnetic resonance-guided focused ultrasound thalamotomy for essential tremor patients with low skull density ratio: a case-matched analysis
    Ng, Patrick R.
    Blitz, Sarah E.
    Chua, Melissa M. J.
    Cosgrove, G. Rees
    FRONTIERS IN NEUROLOGY, 2024, 15
  • [10] Factors Other Than Skull Density Ratio Affect Treatment Outcomes in MR-Guided Focused Ultrasound for Tremor
    Katlowitz, Kalman
    Rozman, Peter
    Pourfar, Michael
    Mogilner, Alon Y.
    NEUROSURGERY, 2020, 67 : 226 - 226