A method for calculating the time-varying equivalent circuit parameters of large-capacity synchronous condenser considering field mutual leakage reactance

被引:0
|
作者
Han, Xiao [1 ]
Liang, Yanping [1 ]
Bian, Xu [1 ]
Wang, Weihao [1 ]
机构
[1] Harbin Univ Sci & Technol, Coll Elect & Elect Engn, Harbin, Peoples R China
基金
黑龙江省自然科学基金;
关键词
electric reactance; equivalent circuits; magnetic fields; synchronous machines; time-varying systems; TRANSIENT PROCESSES; ROTOR; MODEL;
D O I
10.1049/elp2.12435
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Accurate calculation of equivalent circuit parameters is a prerequisite for accurately calculating the large-capacity synchronous condenser parameter model. Due to its special transient operating conditions, the high transient magnetic saturation effect during operation causes the non-linearity and time-varying of the equivalent circuit parameters. The field mutual leakage reactance is the critical factor affecting the field current, and the time-varying of the equivalent circuit parameters is closely related to the field current. However, the existing equivalent circuit parameter calculation methods considering field leakage reactance cannot achieve time-varying parameters. A calculation method of time-varying equivalent circuit parameters based on a back propagation neural network algorithm is proposed, which solves the calculation problem of time-varying equivalent circuit parameters considering field mutual leakage reactance. Then, a 300MVar condenser is taken as the research object, and the proposed method is used to simulate the different operating conditions of the condenser and verified by the finite element method and experiment. The results show that the method improves the calculation accuracy of the equivalent circuit parameter model, reduces the calculation time, and applies to different operating conditions. A time-varying equivalent circuit parameter calculation method considering the field mutual leakage reactance is proposed. The method can effectively consider the non-linear and time-varying characteristics of the equivalent circuit parameters during the large-capacity synchronous condenser transient operation and improve the calculation accuracy of the parameter model. image
引用
收藏
页码:872 / 882
页数:11
相关论文
共 4 条
  • [1] Nonlinear Transient Mathematical Model of Large-Capacity Synchronous Condenser Based on Time-Varying Reactance Parameters
    Han, Xiao
    Liang, Yanping
    Zhu, Erhang
    Bian, Xu
    IEEE ACCESS, 2023, 11 : 35411 - 35420
  • [2] A Calculation Method of Equivalent Circuit Constants with Mutual Leakage Reactance on Synchronous Machine with Damper Winding
    Kano, Takashi
    Nakayama, Hiroki
    Ara, Takahiro
    Matsumura, Toshihiro
    ELECTRICAL ENGINEERING IN JAPAN, 2009, 167 (02) : 71 - 78
  • [3] A calculation method of equivalent circuit constants with mutual leakage reactance on synchronous machine with damper winding
    Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603, Japan
    不详
    不详
    不详
    IEEJ Trans. Ind Appl., 2007, 7 (761-766+11):
  • [4] Characteristics Analysis of Field Winding Inter-Turn Short-Circuit Fault for Large-Capacity Synchronous Condenser Based on Stator Winding Asymmetric Branch Current
    Wang, Weihao
    Bian, Xu
    Huang, Hao
    Liang, Yanping
    IEEE ACCESS, 2023, 11 : 81930 - 81941