Repeatability of Epithelium Thickness Measured by an AS-OCT in Different Grades of Keratoconus and Compared to AS-OCT/Placido Topography

被引:1
|
作者
Wang, Yiran [1 ,2 ,3 ,4 ,5 ]
Ning, Rui [1 ,2 ,3 ,4 ,5 ]
Li, Kexin [1 ,2 ,3 ,4 ,5 ]
Xu, Huilin [1 ,2 ,3 ,4 ,5 ]
Li, Yue [1 ,2 ,3 ,4 ,5 ]
Yang, Yizhou [1 ,2 ,3 ,4 ,5 ]
Gustafsson, Ingemar [6 ]
Zhou, Xingtao [1 ,2 ,3 ,4 ,5 ]
Qu, Xiaomei [1 ,2 ,3 ,4 ,5 ]
Huang, Jinhai [1 ,2 ,3 ,4 ,5 ]
机构
[1] Fudan Univ, Eye & ENT Hosp, Eye Inst, Shanghai, Peoples R China
[2] Fudan Univ, Eye & ENT Hosp, Dept Ophthalmol, Shanghai, Peoples R China
[3] Chinese Acad Med Sci, NHC Key Lab Myopia & Related Eye Dis, Shanghai, Peoples R China
[4] Chinese Acad Med Sci, Key Lab Myopia & Related Eye Dis, Shanghai, Peoples R China
[5] Shanghai Res Ctr Ophthalmol & Optometry, Shanghai, Peoples R China
[6] Lund Univ, Skone Univ Hosp, Dept Clin Sciencess, Ophthalmol, Lund, Sweden
基金
中国国家自然科学基金;
关键词
OPTICAL COHERENCE TOMOGRAPHY; HEIDELBERG ANTERION; CORNEAL TOMOGRAPHY; AGREEMENT; SURFACE; KERATECTOMY; CURVATURE; PROFILES; ARTEMIS; MS-39;
D O I
10.1016/j.ajo.2024.04.001
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare agreement of corneal epithelium thickness (ET) between AS-OCT system (RTVue, Optovue) and AS-OCT/Placido topographer (MS -39, CSO) in eyes with different stages of keratoconus (KC), and to assess the repeatability of RTVue AS-OCT. DESIGN: Prospective reliability analysis. METHODS: KC eyes were classified into forme fruste KC (FFKC), mild, moderate, and severe KC. Agreement was evaluated with Bland-Altman plots and 95% limits of agreement (LoA). The repeatability of RTVue was assessed via within -subject standard deviation (S w ), test- retest variability (TRT), coefficient of variation (CoV), and intraclass correlation coefficient (ICC). RESULTS: A total of 119 KC eyes were enrolled, with 21 being FFKC, 26 mild, 39 moderate, and 34 severe. The 95% LoA ranged between - 5.9 and 4.8 mu m for center epithelium thickness (CET), between - 5.7 and 8.2 mu m for thinnest epithelium thickness (TET). At 1mm measuring points, the 95% LoA of superior, inferior, nasal, and temporal were - 4.2 to 4.7 mu m, - 5.2 to 6.0 mu m, - 7.9 to 10.2 mu m, and - 11.2 to 6.0 mu m. At 3 -mm measuring points, the corresponding values were - 2.8 to 9.3 mu m, - 2.0 to 13.0 mu m, - 4.6 to 9.6 mu m, and - 6.3 to 9.7 mu m, indicating that the 2 instruments were not interchangeable without adjustment. Despite that the repeatability of RTVue measurements in KC patients were acceptable, repeatability decreased gradually with the peripheralization of the measurement points. CONCLUSIONS: The 2 OCT-based devices, RTVue and MS -39, do not provide interchangeable measurements of epithelium thickness in KC patients. Repeatability decreases in cases of more severe KC, emphasizing the importance of grading before clinical examination to avoid diagnostic errors.
引用
收藏
页码:213 / 223
页数:11
相关论文
共 34 条
  • [1] Combination of AS-OCT and Placido disc topography in keratoconus patient
    Lomoriello, Domenico Schiano
    Bono, Valeria
    Savini, Giacomo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [2] Semi-Automated Assessment of Keratoconus using AS-OCT
    Lin, Anna
    Maripudi, Snehaa
    Mohammed, Isa S. K.
    Munir, Wuqaas M.
    Munir, Saleha Z.
    Alexander, Janet L.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2021, 62 (11)
  • [3] Medial Rectus Muscle Resection Versus Plication: A Comparison of Conjunctival-Scleral Thickness Measured by AS-OCT
    Suzuki, Hiroko
    Hikoya, Akiko
    Inagaki, Risako
    Haseoka, Takashi
    Arai, Shinji
    Takagi, Yuuri
    Hotta, Yoshihiro
    Sato, Miho
    JOURNAL OF PEDIATRIC OPHTHALMOLOGY & STRABISMUS, 2022, 59 (04) : 274 - 278
  • [4] Comment on: Corneal Epithelial Thickness Measured Using AS-OCT as a Diagnostic Parameter for Limbal Stem Cell Deficiency
    Wan, Kelvin H.
    Kua, Wee Nie
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2020, 220 : 218 - 218
  • [5] AS-OCT as a Tool for Flap Thickness Measurement After Femtosecond-Assisted LASIK
    Kucumen, Raciha Beril
    Yenerel, Nursal Melda
    Gorgun, Ebru
    Oral, Deniz
    Altunsoy, Muhsin
    Utine, Canan Asli
    Ciftci, Ferda
    OPHTHALMIC SURGERY LASERS & IMAGING, 2011, 42 (01) : 31 - 36
  • [6] Reply to Comment on: Corneal Epithelial Thickness Measured Using AS-OCT as a Diagnostic Parameter for Limbal Stem Cell Deficiency
    Liang, Qingfeng
    Tseng, Chi-Hong
    Deng, Sophie X.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2020, 220 : 218 - 219
  • [7] Effects of Valsalva Maneuver on Anterior Chamber Parameters and Choroidal Thickness in Healthy Chinese: An AS-OCT and SS-OCT Study
    Li, Xingyi
    Wang, Wei
    Chen, Shida
    Huang, Wenbin
    Liu, Yaoming
    Wang, Jiawei
    He, Mingguang
    Zhang, Xiulan
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (09) : OCT189 - OCT195
  • [8] Morphological Features Among Gaussian, Sagittal, and Tangential Curvature Maps in Normal and Keratoconus Eyes Using AS-OCT
    Galvis, Virgilio
    Carrillo, Nicolas
    Hernandez, Cesar A.
    Giron, Juan Miguel
    Salazar, Mariana
    Tello, Alejandro
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2025, 51 (01): : 50 - 50
  • [9] Comparison of Central Corneal Thickness and Anterior Chamber Depth Measured Using LenStar LS900, Pentacam, and Visante AS-OCT
    O'Donnell, Clare
    Hartwig, Andreas
    Radhakrishnan, Hema
    CORNEA, 2012, 31 (09) : 983 - 988
  • [10] Anatomical changes of the anterior segment following circunferential silicone sponge scleral buckling surgery measured with AS-OCT
    Moreno Andrade, Ana Boris
    Matsui, Rodrigo
    Lopez Rubio, Salvador
    Rodriguez Loaiza, Jose Luis
    Graue Wiechers, Federico
    Moreno Andrade, Aureliano
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)