An adaptable model for estimating patient-specific electrical properties of the implanted cochlea

被引:0
|
作者
Bratu, Erin L. [1 ]
Berg, Katelyn A. [2 ]
DeFreese, Andrea J. [2 ]
Gifford, Rene H. [2 ]
Noble, Jack H. [1 ,3 ]
机构
[1] Vanderbilt Univ, Dept Elect & Comp Engn, Nashville, TN 37235 USA
[2] Vanderbilt Univ, Dept Hearing & Speech Sci, Med Ctr, Nashville, TN 37232 USA
[3] Vanderbilt Univ, Dept Comp Sci, Nashville, TN 37235 USA
关键词
cochlear implant; computational modeling; image-guided interventions; ELECTRODES;
D O I
10.1117/12.3008731
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Hearing loss can significantly decrease the quality of life for individuals who do not receive adequate treatment, but fortunately, a variety of treatments exist depending on the nature of the loss. For individuals with severe-to-profound sensorineural hearing loss who have not achieved sufficient restoration of hearing with other treatments, the cochlear implant (CI) may be an option. The CI is a surgically-inserted neural prosthetic that converts sounds to electrical stimuli to directly stimulate auditory nerve fibers, bypassing the causes of dysfunction in the inner ear. While many recipients experience significant success with their implants, others receive little or no benefit. Multiple factors can affect hearing outcomes, including the quality of the program that controls the device. Prior research has endeavored to provide clinicians with objective information about a patient to assist them in identifying the optimal parameters for this program. Multiple comprehensive computational models that simulate electrical activity in the cochlea have been created for this task. However, these models are often not fully customizable or are highly customized to single sets of clinical measurements, requiring the model to be recomputed as these measurements change over time. Our overall goal is to create a new model of equal or better quality that is fully customizable and can adapt to changing clinical measurements without substantial recomputation. In this work, we present preliminary results of a methodology for one component of such a model, which uses non-patient-specific simulations of voltage spread in the cochlea to estimate patient-specific electric potentials.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Evaluation of a high-resolution patient-specific model of the electrically stimulated cochlea
    Cakir, Ahmet
    Dwyer, Robert T.
    Noble, Jack. H.
    MEDICAL IMAGING 2017: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2017, 10135
  • [2] Estimating patient-specific soft-tissue properties in a TKA knee
    Ewing, Joseph A.
    Kaufman, Michelle K.
    Hutter, Erin E.
    Granger, Jeffrey F.
    Beal, Matthew D.
    Piazza, Stephen J.
    Siston, Robert A.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2016, 34 (03) : 435 - 443
  • [3] On the prospect of patient-specific biomechanics without patient-specific properties of tissues
    Miller, Karol
    Lu, Jia
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2013, 27 : 154 - 166
  • [4] In situ validation of a parametric model of electrical field distribution in an implanted cochlea
    Dang, Kai
    Clerc, Maureen
    Vandersteen, Clair
    Guevara, Nicolas
    Gnansia, Dan
    2015 7TH INTERNATIONAL IEEE/EMBS CONFERENCE ON NEURAL ENGINEERING (NER), 2015, : 667 - 670
  • [5] PATIENT-SPECIFIC MODEL OF IRIS MECHANICS
    Jouzdani, Sara
    Amini, Rouzbeh
    Barocas, Victor H.
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE, 2010, 2010, : 949 - 950
  • [6] A patient-specific in vivo tumor model
    Wasserman, R
    Acharya, R
    Sibata, C
    Shin, KH
    MATHEMATICAL BIOSCIENCES, 1996, 136 (02) : 111 - 140
  • [7] Estimating patient-specific maximum recruitable volume in neonatal lungs
    Mcdonald, Mariah Aroha
    Knopp, Jennifer L.
    Kim, K. T.
    Dixon, Bronwyn
    Chase, J. Geoffrey
    IFAC PAPERSONLINE, 2021, 54 (15): : 180 - 185
  • [8] ESTIMATING PATIENT-SPECIFIC SHAPE PRIOR FOR MEDICAL IMAGE SEGMENTATION
    Zhang, Wuxia
    Yan, Pingkun
    Li, Xuelong
    2011 8TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2011, : 1451 - 1454
  • [9] Patient-Specific Sensor Registration for Electrical Source Imaging Using a Deformable Head Model
    Zagorchev, Lyubomir
    Brueck, Matthias
    Flaschner, Nick
    Wenzel, Fabian
    Hyde, Damon
    Ewald, Arne
    Peters, Jurriaan
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2021, 68 (01) : 267 - 275
  • [10] Estimating patient-specific and anatomically correct reference model for craniomaxillofacial deformity via sparse representation
    Wang, Li
    Ren, Yi
    Gao, Yaozong
    Tang, Zhen
    Chen, Ken-Chung
    Li, Jianfu
    Shen, Steve G. F.
    Yan, Jin
    Lee, Philip K. M.
    Chow, Ben
    Xia, James J.
    Shen, Dinggang
    MEDICAL PHYSICS, 2015, 42 (10) : 5809 - 5816