Extraction of His Bundle Pacing Lead: More Difficult than Coronary Sinus Lead Extraction: An Analysis of 3897 Lead Extraction Procedures Including 27 His and 253 Coronary Sinus Lead Removals

被引:0
|
作者
Stefanczyk, Pawel [1 ]
Jachec, Wojciech [2 ]
Kutarski, Andrzej [3 ]
Dabrowski, Pawel [1 ]
Glowniak, Andrzej [3 ]
Nowosielecka, Dorota [4 ]
机构
[1] Pope John Paul II Prov Hosp Zamosc, Dept Cardiol, PL-22400 Zamosc, Poland
[2] Med Univ Silesia, Fac Med Sci Zabrze, Dept Cardiol 2, PL-40055 Katowice, Poland
[3] Med Univ Lublin, Dept Cardiol, PL-20093 Lublin, Poland
[4] Pope John Paul II Prov Hosp Zamosc, Dept Cardiac Surg, PL-22400 Zamosc, Poland
关键词
His bundle pacing lead extraction; lead extraction in conduction system pacing; coronary sinus lead extraction; lead extraction complexity; CARDIAC RESYNCHRONIZATION THERAPY; EXPERT CONSENSUS STATEMENT; RISK STRATIFICATION; PERMANENT; LUMENLESS; SCORE; NEED;
D O I
10.3390/biomedicines12061154
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Background: Experience with the transvenous extraction of leads used for His bundle pacing (HBP) is limited. Methods: Analysis of 3897 extractions including 27 HBP and 253 LVP (left ventricular pacing) leads. Results: The main reason for HBP lead extraction was lead failure (59.26%). The age of HBP and LVP leads (54.52 vs. 50.20 months) was comparable, whereas procedure difficulties were related to the LVP lead dwell time. The extraction of HBP leads > 40 months old was longer than the removal of younger leads (8.57 vs. 3.87 min), procedure difficulties occurred in 14.29%, and advanced tools were required in 28.57%. There were no major complications. The extraction time of dysfunctional or infected leads was similar in the HBP and LVP groups (log-rank p = 0.868) but shorter when compared to groups with other leads. Survival after the procedure did not differ between HBP and LVP groups but was shorter than in the remaining patients. Conclusions: 1. HBP is used in CRT-D systems for resynchronisation of the failing heart in 33.33%. 2. Extraction of HBP leads is most frequently performed for non-infectious indications (59.26%) and most often because of lead dysfunction (33.33%). 3. The extraction of "old" (>40 months) HBP leads is longer (8.57 vs. 3.87 min) and more difficult than the removal of "young" leads due to unexpected procedure difficulties (14.29%) and the use of second line/advanced tools (28.57%), but it does not entail the risk of major complications and procedure-related death and is comparable to those encountered in the extraction of LVP leads of a similar age. 4. Survival after lead extraction was comparable between HBP and LVP groups but shorter compared to patients who underwent the removal of other leads.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Extraction of old His bundle pacing leads and coronary sinus leads - an analysis of 3897 lead extraction procedures including 27 His and 253 coronary sinus lead removals
    Kutarski, A.
    Jachec, W.
    Stefanczyk, P.
    Dabrowski, P.
    Glowniak, A.
    Nowosielecka, D.
    Tulecki, L.
    EUROPEAN HEART JOURNAL, 2024, 45
  • [2] Coronary Sinus Lead Extraction
    Cronin, Edmond M.
    Wilkoff, Bruce L.
    HEART FAILURE CLINICS, 2017, 13 (01) : 105 - +
  • [3] Coronary sinus lead extraction
    Tyers, GFO
    Clark, J
    Wang, Y
    Mills, P
    Bashir, J
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2003, 26 (01): : 524 - 526
  • [4] Coronary sinus lead extraction
    Tyers, GFO
    Clark, J
    Karim, S
    Mills, P
    Bashir, J
    CLINICAL CARDIAC PACING AND ELECTROPHYSIOLOGY, 2003, : 741 - 743
  • [5] PERMANENTLY IMPLANTED CORONARY SINUS LEAD EXTRACTION - IS IT MORE HAZARDOUS THAN CONVENTIONAL PM/ICD LEAD EXTRACTION?
    Kutarski, A.
    Malecka, B.
    Zabek, A.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2009, 20 : S35 - S36
  • [6] Transvenous extraction of His bundle pacing lead: New challenge in the field of lead extraction
    Boczar, Krzysztof
    Zabek, Andrzej
    Debski, Maciej
    Gajek, Jacek
    Elakowski, Jacek L.
    Malecka, Barbara
    CARDIOLOGY JOURNAL, 2019, 26 (06) : 805 - 805
  • [7] Experience with transvenous lead extraction of His bundle pacing leads
    Boczar, Krzysztof
    Slawuta, Agnieszka
    Ciesielski, Adam
    Debski, Maciej
    Ulman, Mateusz
    Golinska-Grzybala, Karolina
    Gajek, Jacek
    Lelakowski, Jacek
    Zabek, Andrzej
    POLISH HEART JOURNAL-KARDIOLOGIA POLSKA, 2024, 82 (09): : 870 - 873
  • [8] Extraction of a coronary sinus lead: always so easy?
    Bontempi, Luca
    Vassanelli, Francesca
    Lipari, Alessandro
    Locantore, Elisa
    Cassa, Marco Belotti
    Salghetti, Francesca
    Elmaghawry, Mohamed
    Vizzardi, Enrico
    D'Aloia, Antonio
    Mahmudov, Rashad
    Cerini, Manuel
    Curnis, Antonio
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2017, 18 (10) : 807 - 810
  • [9] Coronary sinus lead extraction is safe even with prolonged lead inplant duration
    Davenport, JD
    Saari, C
    Kutalek, SP
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (04) : 22A - 22A
  • [10] Coronary Sinus Lead Extraction_Laser Required
    Fender, Erin A.
    Henrikson, Charles A.
    CIRCULATION, 2014, 130