Optimizing a courtyard microclimate with adaptable shading and evaporative cooling in a hot mediterranean climate

被引:0
|
作者
Diz-Mellado, Eduardo [1 ,2 ]
Lopez-Cabeza, Victoria Patricia [1 ]
Rivera-Gomez, Carlos [1 ]
Naboni, Emanuele [2 ,3 ,4 ]
Galan-Marin, Carmen [1 ]
机构
[1] Univ Seville, Escuela Tecn Super Arquitectura, Dept Construcc Arquitecton 1, Avda Reina Mercedes 2, Seville 41012, Spain
[2] Univ Parma, Dipartimento Ingn & Architettura, Viale Sci 181-A, I-43124 Parma, Italy
[3] Royal Danish Acad, Inst Technol, Philip Langes 10, DK-1435 Copenhagen, Denmark
[4] Univ New South Wales, Sydney, Australia
来源
关键词
Courtyard; Thermal comfort; Mean radiant temperature; Relative humidity; Misting and shading systems; Heat waves; OUTDOOR THERMAL COMFORT; HEAT MITIGATION STRATEGIES; DIURNAL TEMPERATURE-RANGE; URBAN SPACES; ENERGY EFFICIENCY; FIELD-MEASUREMENTS; DESIGN VARIANTS; AIR-TEMPERATURE; HUMID CLIMATE; WIDE-RANGE;
D O I
10.1016/j.jobe.2024.109167
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
While in recent years significant improvements have been made in the thermal adaptation of indoor building environments, less progress has been made in improving thermal comfort in transitional spaces next to buildings. This makes it imperative to investigate the thermodynamics of such outdoor urban spaces, particularly in warm locations such as southern Spain. The application of suitable passive systems for the regulation of thermal exchanges and the creation of temperate conditions is explored. In order to determine the thermal comfort of users this study focuses on the assessment of two key parameters, mean radiant temperature and relative humidity, and how these are impacted by shading and misting systems in a courtyard. Field measurements analysed the extent to which shading and misting systems enhance user comfort levels in a Seville courtyard. The results indicate a considerable decrease in temperature, with thermal mitigation of up to 11.7 degrees C below reference points outside the courtyard. The percentage of hours within comfort ranges during heat waves increased by 100% by optimizing the results of an additional experimental campaign and considering results from previous ones. The main novelty of this research lies in the comparative study of standalone and integrated passive cooling strategies aiming to provide optimal results in high temperature and heat wave scenarios. The study findings help understand and estimate the effectiveness of low-cost and easily applicable strategies for maintaining comfort conditions during diurnal and nocturnal cycles in both hot seasons and heat waves.
引用
收藏
页数:24
相关论文
共 42 条
  • [1] Dynamic assessment of whitewash shading and evaporative cooling on the greenhouse microclimate and cucumber growth in a Mediterranean climate
    Nikolaou, Georgios
    Neocleons, Damianos
    Katsoulas, Nikolaos
    Kittas, Constantinos
    [J]. ITALIAN JOURNAL OF AGROMETEOROLOGY-RIVISTA ITALIANA DI AGROMETEOROLOGIA, 2018, 23 (02): : 15 - 26
  • [2] Optimizing the design of courtyard houses for passive cooling in hot, dry regions
    Khan, Hayder M.
    Lane-Serff, Gregory F.
    Dewsbury, Jonathan
    [J]. JOURNAL OF BUILDING PERFORMANCE SIMULATION, 2023, 16 (02) : 231 - 247
  • [3] Evaluating the effectiveness of outdoor evaporative cooling in a hot, arid climate
    Dhariwal, Jay
    Manandhar, Prajowal
    Bande, Lindita
    Marpu, Prashanth
    Armstrong, Peter
    Reinhart, Christoph F.
    [J]. BUILDING AND ENVIRONMENT, 2019, 150 : 281 - 288
  • [4] Effectiveness of indirect evaporative cooling and thermal mass in a hot arid climate
    Kruger, Eduardo
    Gonzalez Cruz, Eduardo
    Givoni, Baruch
    [J]. BUILDING AND ENVIRONMENT, 2010, 45 (06) : 1422 - 1433
  • [5] An experimental evaluation of indirect direct evaporative cooling unit for hot climate
    Tashtoush, Bourhan
    Chilengwe, Nelson
    Musthafa, Mohamed
    Horr, Yousef Al
    [J]. INTERNATIONAL JOURNAL OF GLOBAL WARMING, 2021, 24 (3-4) : 237 - 260
  • [6] Passive cooling ability of a courtyard house in a hot and arid climate: A real case study
    Fardeheb, Fewzi
    [J]. PROCEEDINGS OF ISES SOLAR WORLD CONGRESS 2007: SOLAR ENERGY AND HUMAN SETTLEMENT, VOLS I-V, 2007, : 2516 - 2520
  • [7] Performance characteristics of a pad evaporative cooling system in a broiler house in a Mediterranean climate
    Dagtekin, Metin
    Karaca, Cengiz
    Yildiz, Yilmaz
    [J]. BIOSYSTEMS ENGINEERING, 2009, 103 (01) : 100 - 104
  • [8] A comparison between atrium and courtyard cooling efficiency in hot tropical climate, implementing different passive cooling strategies
    Moosavi, Leila
    Mahyuddin, Norhayati
    Ab Ghafar, Norafida
    [J]. JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2015, 7 (04)
  • [9] Sustainable cooling system for Kuwait hot climate combining diurnal radiative cooling and indirect evaporative cooling system
    Katramiz, Elvire
    Al Jebaei, Hussein
    Alotaibi, Sorour
    Chakroun, Walid
    Ghaddar, Nesreen
    Ghali, Kamel
    [J]. ENERGY, 2020, 213
  • [10] Numerical investigation of evaporative cooling strategies on the aero-thermal performance of courtyard buildings in hot-dry climates
    Sun, Hao
    Zhong, Hua
    Dik, Abdullah
    Ding, Kemin
    Jimenez-Bescos, Carlos
    Calautit, John Kaiser
    [J]. BUILDING AND ENVIRONMENT, 2024, 258