Electronic tongue and nose sensor coupled with fluorescence spectroscopy to analyze aesthetic water quality parameters in drinking water distribution system

被引:2
|
作者
Nam, Sook-Hyun [1 ]
Lee, Juwon [1 ,2 ]
Kim, Eunju [1 ]
Shin, Yonghyun [1 ]
Koo, Jae-Wuk [1 ]
Kye, Homin [1 ]
Park, Jeongbeen [1 ,2 ]
Jeon, Hyeongwoo [3 ]
Song, Youngjae [3 ]
Hwang, Tae-Mun [1 ,2 ]
机构
[1] Korea Inst Civil Engn & Bldg Technol, 283 Goyangdar Ro, Goyang Si 411712, Gyeonggi Do, South Korea
[2] Korea Univ Sci & Technol, 217 Gajung To Yuseong Gu, Daejeon 305333, South Korea
[3] Waterworks Headquarters Incheon Metropolitan City, Waterworks Res Inst, 332 Bupyeong Daero, Incheon 21316, South Korea
关键词
Aesthetic water quality; Electronic tongue; Electronic nose; Fluorescence spectroscopy; Taste Index (TI); Odor Index (OI); DISSOLVED ORGANIC-MATTER; CLUSTER-ANALYSIS; TREATMENT-PLANT; ODOR; IDENTIFICATION; CONTAMINATION; CARBON; TASTE;
D O I
10.1016/j.psep.2024.05.134
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this study, a new method is proposed for the evaluation of taste and odor of drinking water quality in water distribution systems by means of objective and quantitative indices derived from electronic sensors and fluorescence spectroscopy analysis. This method can be analyzed easily, quickly, and instead of subjective sensory analysis. Taste index (T.I.) and odor index (O.I.) were derived using an electronic tongue and nose. This method is simpler, faster, and less expensive than human panel methods. The tryptophan-like fluorescence index (TLF-I) and pipe deterioration index (PDI) of the water distribution system, derived from fluorescence spectroscopy, were also calculated to determine if the T.I. and O.I. were high or what was causing the difference. The target of comparison was the final water (point 1) that supplies water, and T.I., O.I., TLF-I, and PDI were calculated for the seven sampled points. Points 5 (3.91), 3 (3.82), and 6 (3.66) observed high T.I. O.I. was highest in the order of points 6 (3.65), 3 (3.16), and 5 (2.51). High TLF-I was observed at points 5 (160), 3 (111), and 6 (89), indexing a solid correlation. Other influencing factors at points 5, 3, and 6 included the PDI and water supply of the reservoir type. Point 5 had the highest PDI of 0.47. These results suggest that TLF-I and PDI can serve as indicators for interpreting the causes of changes in T.I. and O.I., which are indicators of aesthetic water quality. This method can assist in managing taste and odor quality data in drinking water distribution networks.
引用
收藏
页码:1201 / 1210
页数:10
相关论文
共 50 条
  • [1] Use of an Electronic Tongue System and Fuzzy Logic to Analyze Water Samples
    Braga, Guilherme S.
    Paterno, Leonardo G.
    Fonseca, Fernando J.
    OLFACTION AND ELECTRONIC NOSE, PROCEEDINGS, 2009, 1137 : 504 - 506
  • [2] New sensor system for drinking water quality
    Lindquist, M
    Wide, P
    PROCEEDINGS OF THE ISA/IEEE SENSORS FOR INDUSTRY CONFERENCE, 2004, : 30 - 34
  • [3] Relationships between levels of heterotrophic bacteria and water quality parameters in a drinking water distribution system
    Carter, JT
    Rice, EW
    Buchberger, SG
    Lee, Y
    WATER RESEARCH, 2000, 34 (05) : 1495 - 1502
  • [4] Online monitoring of drinking water quality in a distribution network: a selection procedure for suitable water quality parameters and sensor devices
    Lee, Adam
    Francisque, Alex
    Najjaran, Homayoun
    Rodriguez, Manuel J.
    Hoorfar, Mina
    Imran, Syed A.
    Sadiq, Rehan
    INTERNATIONAL JOURNAL OF SYSTEM ASSURANCE ENGINEERING AND MANAGEMENT, 2012, 3 (04) : 323 - 337
  • [5] Online monitoring of drinking water quality in a distribution network: a selection procedure for suitable water quality parameters and sensor devices
    Adam Lee
    Alex Francisque
    Homayoun Najjaran
    Manuel J. Rodriguez
    Mina Hoorfar
    Syed A. Imran
    Rehan Sadiq
    International Journal of System Assurance Engineering and Management, 2012, 3 (4) : 323 - 337
  • [6] An electronic nose system for monitoring the quality of potable water
    Gardner, JW
    Shin, HW
    Hines, EL
    Dow, CS
    SENSORS AND ACTUATORS B-CHEMICAL, 2000, 69 (03) : 336 - 341
  • [7] Assessment of drinking water quality at the tap using fluorescence spectroscopy
    Heibati, Masoumeh
    Stedmon, Colin A.
    Stenroth, Karolina
    Rauch, Sebastien
    Toljander, Jonas
    Save-Soderbergh, Melle
    Murphy, Kathleen R.
    WATER RESEARCH, 2017, 125 : 1 - 10
  • [8] The impact of flushing the drinking water distribution system pipeline on the quality of drinking water and microorganisms
    Zhang, Xinxin
    Wei, Dong
    Li, Chunying
    Zhao, Qiushi
    Liu, Zhongyu
    Zhang, Hongqiang
    Tang, Jiawei
    Ding, Yanqun
    Jia, Ouyang
    Luo, Erming
    Wei, Li
    JOURNAL OF WATER PROCESS ENGINEERING, 2025, 69
  • [9] Assessing water quality of drinking water distribution system in the South Taiwan
    Lou, Jie-Chung
    Han, Jia-Yun
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2007, 134 (1-3) : 343 - 354
  • [10] Assessing water quality of drinking water distribution system in the South Taiwan
    Jie-Chung Lou