Canonical Variate Analysis for Detecting False Data Injection Attacks in Alternating Current State Estimation

被引:0
|
作者
Pei, Chao [1 ,2 ,3 ]
Xiao, Yang [3 ]
Liang, Wei [4 ,5 ]
Han, Xiaojia [3 ,6 ]
Wang, Wenhai [2 ,7 ,8 ]
机构
[1] Zhejiang Univ, Coll Control Sci & Engn, Hangzhou 310027, Peoples R China
[2] Zhejiang Univ NG Platform, Hangzhou 310027, Peoples R China
[3] Univ Alabama, Dept Comp Sci, Tuscaloosa, AL 35487 USA
[4] Chinese Acad Sci, Key Lab Networked Control Syst, Shenyang 110016, Peoples R China
[5] Chinese Acad Sci, Shenyang Inst Automat, Shenyang 110016, Peoples R China
[6] Zhejiang Lab, Res Ctr Intelligent Equipment, Hangzhou 311100, Peoples R China
[7] Zhejiang Univ, Coll Control Sci & Engn, State Key Lab Ind Control Technol, Hangzhou 310027, Peoples R China
[8] Zhejiang Univ, Inst Control Equipment & Comprehens Safety, Coll Control Sci & Engn, Hangzhou 310027, Peoples R China
关键词
State estimation; Smart grids; Transmission line measurements; Power systems; Phasor measurement units; Voltage measurement; Power measurement; Cyber-physical systems (CPS); security; smart grid; false data injection attacks (FDIAs); canonical variate analysis; Alternating Current (AC) state estimation; PROTECTION; SECURITY; DEFENSE;
D O I
10.1109/TNSE.2024.3370649
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Estimating the accurate states of voltage magnitudes and angles ensures reliable operation and control in a smart grid. The increased dependency and integration of information communication technologies in smart grids introduce new security issues, such as hidden false data injection attacks (FDIAs). These can successfully evade conventional residual-based detection mechanisms and cause bias to the estimated states. Since complicated power systems exhibit nonlinear characteristics, it is particularly critical to achieving satisfactory detection performance against FDIAs in Alternating Current (AC) state estimation models rather than widely-used simplified Direct Current (DC) models. This paper proposes a novel Canonical Variate Analysis (CVA)-based detection approach against FDIAs in an AC power system. Our proposed method utilizes the fact that the occurrence of FDIAs affects the correlation of consecutive measurements, including cross-correlation and auto-correlation. Unlike many of the previous studies in DC estimation models, which are not very realistic, we study the detection performance of the CVA-based detection method for AC estimation, in which kernel density estimation is introduced to determine detection thresholds. Furthermore, instead of adding advanced Phasor Measurement Units' measurements or forecasting-aided redundant measurements to increase the attack detection capability, the proposed approach is a data-based multivariate statistical monitoring process that directly monitors changes in multiple state variables. The performance of our proposed approach is verified on an IEEE 14 bus system, and different attack scenarios are considered in our experiments. Experiment results indicate that our approach performs better for FDIAs than an existing Kullback-Leibler-Distance detector.
引用
收藏
页码:3332 / 3345
页数:14
相关论文
共 50 条
  • [1] Detecting False Data Injection Attacks Using Canonical Variate Analysis in Power Grid
    Pei, Chao
    Xiao, Yang
    Liang, Wei
    Han, Xiaojia
    IEEE TRANSACTIONS ON NETWORK SCIENCE AND ENGINEERING, 2021, 8 (02): : 971 - 983
  • [2] Detecting False Data Injection Attacks in AC State Estimation
    Gu Chaojun
    Jirutitijaroen, Panida
    Motani, Mehul
    IEEE TRANSACTIONS ON SMART GRID, 2015, 6 (05) : 2476 - 2483
  • [3] Optimal Coding Schemes for Detecting False Data Injection Attacks in Power System State Estimation
    Liu, Chensheng
    Deng, Ruilong
    He, Wangli
    Liang, Hao
    Du, Wenli
    IEEE TRANSACTIONS ON SMART GRID, 2022, 13 (01) : 738 - 749
  • [4] Impact analysis of false data injection attacks on distribution system state estimation
    Molnar, Martin
    Vokony, Istvan
    2021 21ST IEEE INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING AND 2021 5TH IEEE INDUSTRIAL AND COMMERCIAL POWER SYSTEMS EUROPE (EEEIC/I&CPS EUROPE), 2021,
  • [5] State estimation under false data injection attacks: Security analysis and system protection
    Hu, Liang
    Wang, Zidong
    Han, Qing-Long
    Liu, Xiaohui
    AUTOMATICA, 2018, 87 : 176 - 183
  • [6] Partial grid false data injection attacks against state estimation
    Margossian, Harag
    Sayed, Mohammad Ali
    Fawaz, Wissam
    Nakad, Zahi
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2019, 110 : 623 - 629
  • [7] Voltage regulation strategy for alternating current microgrid under false data injection attacks
    Guan, Rongqiang
    Yi, Jing
    Fan, Siyuan
    Sun, Tianyi
    Liu, Peng
    Gao, Han
    ARCHIVES OF ELECTRICAL ENGINEERING, 2024, 73 (01) : 251 - 264
  • [8] Data-Driven False Data Injection Attacks on State Estimation in Smart Grid
    Li, Qinxue
    Cui, Delong
    Liu, Mei
    2018 37TH CHINESE CONTROL CONFERENCE (CCC), 2018, : 6190 - 6195
  • [9] Impact of False Data Injection Attacks on PMU-based State Estimation
    Basumallik, Sagnik
    Eftekharnejad, Sara
    Davis, Nathan
    Johnson, Brian. K.
    2017 NORTH AMERICAN POWER SYMPOSIUM (NAPS), 2017,
  • [10] False Data Injection Attacks Against State Estimation Without Knowledge of Estimators
    Lu, An-Yang
    Yang, Guang-Hong
    IEEE TRANSACTIONS ON AUTOMATIC CONTROL, 2022, 67 (09) : 4529 - 4540