Comparison of Various Commonly Used Luting Cements on the Success of Composite Inlays Assessed by the Levels of the Microleakage-An In vitro Study

被引:0
|
作者
Uppalapati, Vishwaja [1 ]
Shivanand, Sunita [2 ]
Agarwal, Ishita [3 ]
Mustafa, Mohammed [4 ]
Dutta, Smita D. [5 ]
Sharma, Mayank [6 ]
机构
[1] Conservat Dentist & Endodont, Hyderabad, Telangana, India
[2] KAHER, KLE VK Inst Dent Sci, Dept Conservat Dent & Endodont, Belagavi, Karnataka, India
[3] Seema Dent Coll & Hosp, Dept Conservat Dent & Endodont, Rishikesh, Uttarakhand, India
[4] Prince Sattam Bin Abdulaziz Univ, Dept Conservat Dent Sci, Coll Dent, Al Kharj, Saudi Arabia
[5] Qassim Univ, Dept Conservat Dent Sci & Endodont, Coll Dent, Buraydah, Saudi Arabia
[6] Cent Coast Dent Care, Dent, Seaside, CA USA
关键词
Composites; luting; microleakage; RelyX Unicem; Variolink N;
D O I
10.4103/jpbs.jpbs_438_23
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Introduction: Indirect composite restoration is one of the commonly followed procedures in the posterior teeth. The success of this is dependent on many factors, one being the luting cement. Hence, the current study explores the microleakage of the two luting cements at 2 different times. Materials and Methods: Eighty extracted human teeth were taken, and class II cavities were made that were to receive the composite inlays. They were grouped as supragingival and subgingival, which for further divided as were further subdivided to be observed for marginal leakage at cervical and occlusal margins, at the end of a day and 1 month. Each group had ten specimens. The luting cements that were evaluated were Variolink N and RelyX Unicem. After the composite inlay restoration was done for all the specimens, the sections were put on slides, and a stereomicroscope was used to measure the amount of dye penetration. Leakage was evaluated and compared using Mann-Whitney U test. Results: At the end of 1 day, there was no significant alteration in the microleakage in the occlusal or cervical regions for either region supragingivally or subgingivally between the two luting cements. Significant difference between the two cements at the cervical borders at the end of a month was seen for both the margins. When compared supragingivally and subgingivally at the end of 1 day or at the end of 1 month, there was not a significant difference for any of the cements. Conclusion: Within the constraints of the current investigation, it can be said that there was similar microleakage for both Variolink N and RelyX Unicem at the conclusion of a day's storage time. After a 1-month storage period, RelyX Unicem showed more cervical microleakage than Variolink N.
引用
收藏
页码:S162 / S164
页数:3
相关论文
共 5 条
  • [1] Cytotoxicity of commonly used luting cements -An in vitro study
    Trumpaite-Vanagiene, Rita
    Bukelskiene, Virginija
    Aleksejuniene, Jolanta
    Puriene, Alina
    Baltriukiene, Daiva
    Rutkunas, Vygandas
    DENTAL MATERIALS JOURNAL, 2015, 34 (03) : 294 - 301
  • [2] COMPARISON OF MARGINAL FIT AND MICROLEAKAGE OF CERAMIC AND COMPOSITE INLAYS - AN IN-VITRO STUDY
    THORDRUP, M
    ISIDOR, F
    HORSTEDBINDSLEY, P
    JOURNAL OF DENTISTRY, 1994, 22 (03) : 147 - 153
  • [3] Comparison of microleakage of three acid-base luting cements versus one resin-bonded cement for Class V direct composite inlays
    Piemjai, M
    Miyasaka, K
    Iwasaki, Y
    Nkaabayashi, N
    JOURNAL OF PROSTHETIC DENTISTRY, 2002, 88 (06): : 598 - 603
  • [4] Filler content and gap width after luting of ceramic inlays, using the ultrasonic insertion technique and composite resin cements - An in vitro study
    Sjogren, G
    Hedlund, SO
    ACTA ODONTOLOGICA SCANDINAVICA, 1997, 55 (06) : 403 - 407
  • [5] Comparison of Microleakage in Nanocomposite and Amalgam as a Crown Foundation Material Luted with Different Luting Cements under CAD-CAM Milled Metal Crowns: An In Vitro Microscopic Study
    Amina
    Rajput, Geeta
    Ahmed, Saad
    Chaturvedi, Saurabh
    Addas, Mohamed Khaled
    Bhagat, Tushar Vitthalrao
    Gurumurthy, Vishwanath
    Alqahtani, Saeed M.
    Alobaid, Mohammed A.
    Alsubaiy, Ebrahim Fihaid
    Gupta, Kanishk
    POLYMERS, 2022, 14 (13)