Optimizing gamma-ray shielding for boron neutron capture therapy by using unglazed ceramic composites

被引:1
|
作者
Ali, M. S. [1 ]
Hassan, G. S. [2 ]
Shoraiet, G. M. [1 ]
Abdelmonem, A. M. [3 ]
机构
[1] New Valley Univ, Fac Sci, Phys Dept, Al Kharja, Egypt
[2] Assiut Univ, Fac Sci, Phys Dept, Assiut, Egypt
[3] Egyptian Atom Energy Author EAEA, Nucl Res Ctr, Reactor Phys Dept, Cairo, Egypt
关键词
BNCT; Unglazed ceramic composites; Gamma -ray filters; Beam shaping assembly; Cancer particle therapy; ATTENUATION; EFFICIENCY; LEAD;
D O I
10.1016/j.nimb.2024.165450
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In this study, the researchers investigated the effectiveness of different ceramic samples in filtering gamma rays emitted by various sources. The samples, which contained varying concentrations of lead and barium, were evaluated for their potential use in beam-shaping assembly systems for Boron Neutron Capture Therapy techniques, specifically those using the 252Cf neutron source for cancer treatment. Stilbene and NaI (Tl) were used to measure the total and pure gamma rays in this study. In addition, theoretical calculations using the Phy-X/PSD software have been conducted across a broad energy range, spanning from 0.001 to 18 MeV. These calculations aim to determine the attenuation of gamma rays and the relative deviations compared to the corresponding measured gamma-ray energies. Various composites with different percentages of additives and thicknesses, ranging from 0.8 cm to 4 cm, have shown satisfactory attenuation properties for gamma-ray shielding applications. However, the samples containing lead, especially the unglazed ceramic composites with 15 % lead and 4 cm thickness, were found to have the most preferred attenuation properties. The results obtained indicate that samples with a higher lead content are more effective attenuators compared to those with additional barium. In addition, the relationship between the transmission gamma ray factor and the percentage of additives and energies of gamma rays can be determined from the experimental linear attenuation coefficient coefficients. In addition, various coefficients such as the mass attenuation coefficient, half-value layer, effective atomic numbers, and effective electron densities are studied theoretically for the unglazed ceramic samples. The dose rate is also taken into consideration.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] BeNEdiCTE (Boron Neutron Capture): A Versatile Gamma-Ray Detection Module for Boron Neutron Capture Therapy
    Caracciolo, Anita
    Buonanno, Luca
    Di Vita, Davide
    D'Adda, Ilenia
    Chacon, Andrew
    Kielly, Marissa
    Carminati, Marco
    Safavi-Naeini, Mitra
    Fiorini, Carlo
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2022, 6 (08) : 886 - 892
  • [2] Boron analysis for neutron capture therapy using particle-induced gamma-ray emission
    Nakai, Kei
    Yamamoto, Yohei
    Okamoto, Emiko
    Yamamoto, Tetsuya
    Yoshida, Fumiyo
    Matsumura, Akira
    Yamada, Naoto
    Kitamura, Akane
    Koka, Masashi
    Satoh, Takahiro
    APPLIED RADIATION AND ISOTOPES, 2015, 106 : 166 - 170
  • [3] Gamma-ray and neutron shielding features for some fast neutron moderators of interest in 252Cf-based boron neutron capture therapy
    Elsheikh, Nassreldeen A. A.
    APPLIED RADIATION AND ISOTOPES, 2020, 156
  • [4] A comparative neutron and gamma-ray radiation shielding investigation of molybdenum and boron filled polymer composites
    Ogul, H.
    Agar, O.
    Bulut, F.
    Kacal, M. R.
    Dilsiz, K.
    Polat, H.
    Akman, F.
    APPLIED RADIATION AND ISOTOPES, 2023, 194
  • [5] DETERMINATION OF BORON BY THERMAL NEUTRON CAPTURE GAMMA-RAY ANALYSIS
    GARBRAH, BW
    WHITLEY, JE
    ANALYTICAL CHEMISTRY, 1967, 39 (03) : 345 - &
  • [6] Neutron and gamma-ray shielding effectiveness of novel polyaniline composites
    Kahraman, Deniz Agehan
    Cogalmis, Fatma Tuba
    Esen, Ayse Nur
    Haciyakupoglu, Sevilay
    Senkal, Bahire Filiz
    RADIATION PHYSICS AND CHEMISTRY, 2024, 219
  • [7] DETERMINATION OF BORON IN GLASS BY THERMAL NEUTRON CAPTURE GAMMA-RAY ANALYSIS
    GARBRAH, BW
    WHITLEY, JE
    GLASS TECHNOLOGY, 1967, 8 (06): : 154 - +
  • [8] EFFECTIVENESS OF EPITHERMAL NEUTRON BEAM AND GAMMA RADIATION SHIELDING FOR BORON NEUTRON CAPTURE THERAPY
    Rabochova, S. M.
    Vins, M.
    Viererbl, L.
    Lahodova, Z.
    Klupak, V.
    Soltes, J.
    RAD 2015: THE THIRD INTERNATIONAL CONFERENCE ON RADIATION AND APPLICATIONS IN VARIOUS FIELDS OF RESEARCH, 2015, : 75 - 77
  • [9] γ-Ray measurements in boron neutron capture therapy using BeO ceramic thermoluminescence dosimeter
    Tanaka, Masaya
    Oh, Ryoken
    Sugioka, Natsumi
    Tanaka, Hiroki
    Takata, Takushi
    Wakabayashi, Genichiro
    Sugawara, Satoru
    Watanabe, Kenichi
    Uritani, Akira
    Yoshihashi, Sachiko
    Nagasaka, Kosei
    Okada, Go
    Negishi, Toru
    Shinsho, Kiyomitsu
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN ELECTRONICS, 2022, 33 (25) : 20271 - 20279
  • [10] γ-Ray measurements in boron neutron capture therapy using BeO ceramic thermoluminescence dosimeter
    Masaya Tanaka
    Ryoken Oh
    Natsumi Sugioka
    Hiroki Tanaka
    Takushi Takata
    Genichiro Wakabayashi
    Satoru Sugawara
    Kenichi Watanabe
    Akira Uritani
    Sachiko Yoshihashi
    Kosei Nagasaka
    Go Okada
    Toru Negishi
    Kiyomitsu Shinsho
    Journal of Materials Science: Materials in Electronics, 2022, 33 : 20271 - 20279