OPTIMIZED CASING TREATMENT TO IMPROVE STALL MARGIN UNDER CIRCUMFERENTIAL PRESSURE DISTORTION IN A HIGH-SPEED AXIAL FLOW FAN

被引:0
|
作者
Li, Yihan [1 ,2 ]
Li, Jichao [1 ,2 ]
Du, Juan [1 ,2 ]
Liu, Yang [1 ,2 ]
Zhang, Min [1 ,2 ]
Zhang, Hongwu [1 ,2 ]
机构
[1] Chinese Acad Sci, Adv Gas Turbine Lab, Inst Engn Thermophys, Beijing 100190, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100190, Peoples R China
基金
中国国家自然科学基金;
关键词
High-speed fan; Circumferential distortion; Casing Treatment; Unsteady measurements;
D O I
暂无
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
Aviation fans often suffer from the negative effect of distorted inflow on the stall margin. An effective way to solve the aforementioned problem is to apply casing treatment for extending the stall margin. However, previously, it was observed that casing treatments often increase the stability but with reduced efficiency. Therefore, an optimized axial slot casing treatment (OPCT) was designed that improves the stall margin by 7.31% with 1.97% efficiency gain at a design speed of 100% in a high-speed axial flow fan. The stability-enhancing effect of the OPCT under distorted inflow was further evaluated. Based on the airworthiness standard, the distorted inflow with 9% of composite distortion index was tested with OPCT. At 100% design speed, the OPCT can still improve the stall margin by 6.19% with an improvement in efficiency by 1.63%. The stall margin improvement due to the OPCT at 80% design speed can be up to 13.31% with an improvement in efficiency by 0.87%. The unsteady measurement results under distorted inflow indicate that the location of the shock wave obviously moves forward towards the blade tip leading edge as the rotor blade rotates out of the distorted region. This in turn leads to an earlier stall of the fan compared to that at uniform inflow. When the OPCT is applied, although the fluctuation of the tip leakage vortex in the slot region is stronger than that in smooth casing, the strength of the interaction between the shock wave and tip leakage flow can be suppressed, and the location of the shock wave at the distorted region is pushed back towards the blade passage by the OPCT. Consequently, the transition from the disturbance downstream of the distortion region to the stall inception is postponed. It was experimentally discovered that the casing treatment does not alter the instability mode of the fan, and the fan eventually surges, which is consistent with B parameter value of 2.942. However, under the distorted inflow, B parameter can be reduced from 2.942 to 0.863, and thereby, the instability mode of the fan is changed from surge under uniform inflow to stall under distorted inflow. The aforementioned phenomena can guide the instability prediction when the fan encounters distortion or casing treatment is applied in future studies.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Optimized Casing Treatment to Improve Stall Margin Under Circumferential Pressure Distortion in a High-Speed Axial Flow Fan
    Li, Yihan
    Du, Juan
    Li, Jichao
    Liu, Yang
    Ba, Dun
    Zhang, Min
    Zhang, Hongwu
    JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2025, 147 (01):
  • [2] Stall margin enhancement of a novel casing treatment subjected to circumferential pressure distortion
    Dong, Xu
    Sun, Dakun
    Li, Fanyu
    Sun, Xiaofeng
    AEROSPACE SCIENCE AND TECHNOLOGY, 2018, 73 : 239 - 255
  • [3] Hybrid Slot-Groove Casing Treatment for Stall Margin Improvement on an Axial Flow Compressor with Circumferential Total Pressure Distortion
    Yihan Li
    Jichao Li
    Chen Yang
    Juan Du
    Hongwu Zhang
    Chaoqun Nie
    Journal of Thermal Science, 2023, 32 : 770 - 785
  • [4] Hybrid Slot-Groove Casing Treatment for Stall Margin Improvement on an Axial Flow Compressor with Circumferential Total Pressure Distortion
    LI Yihan
    LI Jichao
    YANG Chen
    DU Juan
    ZHANG Hongwu
    NIE Chaoqun
    Journal of Thermal Science, 2023, 32 (02) : 770 - 785
  • [5] Hybrid Slot-Groove Casing Treatment for Stall Margin Improvement on an Axial Flow Compressor with Circumferential Total Pressure Distortion
    Li, Yihan
    Li, Jichao
    Yang, Chen
    Du, Juan
    Zhang, Hongwu
    Nie, Chaoqun
    JOURNAL OF THERMAL SCIENCE, 2023, 32 (02) : 770 - 785
  • [6] Performance Enhancement of a Transonic Axial Flow Compressor with Circumferential Casing Grooves to Improve the Stall Margin
    Ahmad, N.
    Bin, J.
    Qun, Z.
    Ahmad, S. Abdu
    Fawzy, H.
    JOURNAL OF APPLIED FLUID MECHANICS, 2020, 13 (01) : 221 - 232
  • [7] Axial Slot Casing Treatment for Stall Margin Improvement in an Axial Flow Compressor With Radial Distortion
    Li, Yihan
    Li, Jichao
    Li, Fan
    Du, Juan
    Zhang, Hongwu
    Nie, Chaoqun
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2022, 43 (05): : 1210 - 1218
  • [8] An Optimization Study of Circumferential Groove Casing Treatment in a High-Speed Axial Flow Compressor
    Liu, Wenhao
    Chu, Wuli
    Zhang, Haoguang
    Wang, Hao
    AEROSPACE, 2024, 11 (07)
  • [9] Flow mechanism for stall margin improvement due to circumferential casing grooves on axial compressors
    Shabbir, A
    Adamczyk, JJ
    JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2005, 127 (04): : 708 - 717
  • [10] Investigation on Flow Mechanisms of Stall Margin Improvement of Compound Slots Casing Treatment for a 3.5-Stage High-Speed Axial-Flow Compressor
    Zhang, Xiawen
    Hua, Yu
    Li, Cong
    Ju, Yaping
    Zhang, Chuhua
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2023, 44 (10): : 2673 - 2684