Smartphone-Based Recognition of Heart Failure by Means of Microelectromechanical Sensors

被引:0
|
作者
Haddad, Francois [1 ,8 ]
Saraste, Antti [2 ,3 ]
Santalahti, Kristiina M. [4 ]
Pankaala, Mikko [3 ,4 ]
Kaisti, Matti [3 ,4 ]
Kandolin, Riina [5 ]
Simonen, Piia [5 ]
Nammas, Wail [2 ]
Dehkordi, Kamal Jafarian [4 ]
Koivisto, Tero [3 ,4 ]
Knuuti, Juhani [3 ,6 ]
Mahaffey, Kenneth W. [1 ]
Blomster, Juuso I. [3 ,4 ,7 ]
机构
[1] Stanford Univ, Sch Med, Stanford Ctr Prevent Res, Palo Alto, CA 94305 USA
[2] Turku Univ Hosp, Heart Ctr, Turku, Finland
[3] Univ Turku, Turku, Finland
[4] CardioSignal, Turku, Finland
[5] Helsinki Univ Hosp, Helsinki, Finland
[6] Turku Univ Hosp, Turku PET Ctr, Turku, Finland
[7] Turku Univ Hosp, Res Serv, Turku, Finland
[8] Stanford Univ, Stanford Cardiovasc Inst, Stanford Ctr Clin Res, Sch Med, 300 Pasteur Dr, Palo Alto, CA 94305 USA
基金
芬兰科学院;
关键词
diagnostics; digital biomarker; heart failure; microelectromechanic al sensors; sensors; smartphone; MECHANICS; DISEASE;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Heart failure (HF) is the leading cause of hospitalization in individuals over 65 years of age. Identifying noninvasive methods to detect HF may address the epidemic of HF. Seismocardiography which measures cardiac vibrations transmitted to the chest wall has recently emerged as a promising technology to detect HF. OBJECTIVES In this multicenter study, the authors examined whether seismocardiography using commercially available smartphones can differentiate control subjects from patients with stage C HF. METHODS Both inpatients and outpatients with HF were enrolled from Finland and the United States. Inpatients with HF were assessed within 2 days of admission, and outpatients were assessed in the ambulatory setting. In a prespecified pooled data analysis, algorithms were derived using logistic regression and then validated using a bootstrap aggregation method. RESULTS A total of 217 participants with HF (174 inpatients and 172 outpatients) and 786 control subjects from cardiovascular clinics were enrolled. The mean age of participants with acute HF was 64 +/- 13 years, 64.9% were male, left ventricular ejection fraction was 39% +/- 15%, and median N -terminal pro -B-type natriuretic peptide was 5,778 ng/L (Q1Q3: 1,933 -6,703). The majority (74%) of participants with HF had reduced EF, and 38% had atrial fibrillation. Across both HF cohorts, the algorithms had an area under the receiver operating characteristic curve of 0.95 with a sensitivity of 85%, specificity of 90%, and accuracy of 89% for the detection of HF, with a decision threshold of 0.5. The positive and negative likelihood ratios were 8.50 and 0.17, respectively. The accuracy of the algorithms was not significantly different in subgroups based on age, sex, body mass index, and atrial fibrillation. CONCLUSIONS Smartphone-based assessment of cardiac function using seismocardiography is feasible and differentiates patients with HF from control subjects with high diagnostic accuracy. (Recognition of Heart Failure With Micro Electro-mechanical Sensors FI; NCT04444583; Recognition of Heart Failure With Micro Electro-mechanical Sensors [NCT04378179]; Detection of Coronary Artery Disease With Micro Electro-mechanical Sensors; NCT04290091) (c) 2024 Published by Elsevier on behalf of the American College of Cardiology Foundation.
引用
收藏
页码:1030 / 1040
页数:11
相关论文
共 50 条
  • [1] Smartphone-Based Sensors
    Gao, Xuefei
    Wu, Nianqiang
    [J]. ELECTROCHEMICAL SOCIETY INTERFACE, 2016, 25 (04): : 79 - 81
  • [2] SmartBEAT: A Smartphone-Based Heart Failure Telemonitoring Solution
    Silva-Cardoso, Jose
    Moreira, Emilia
    Lopes, Ines
    Sousa, Carla
    Leite, Sergio
    Campelo, Manuel
    Sousa, Jose Maria
    Fonseca, Manuela
    Harnevo, Linda
    Farin, Moshe
    Azevedo, Luis Filipe
    Sousa, Filipe
    [J]. XV MEDITERRANEAN CONFERENCE ON MEDICAL AND BIOLOGICAL ENGINEERING AND COMPUTING - MEDICON 2019, 2020, 76 : 1369 - 1376
  • [3] Smartphone-Based Remote Monitoring Solution for Heart Failure Patients
    Lopes, Ines
    Sousa, Filipe
    Moreira, Emilia
    Cardoso, Jose
    [J]. PHEALTH 2019, 2019, 261 : 109 - 114
  • [4] Smartphone-Based Palmprint Recognition System
    Moco, Nuno Freire
    Correia, Paulo Lobato
    Soares, Luis Ducla
    [J]. 2014 21ST INTERNATIONAL CONFERENCE ON TELECOMMUNICATIONS (ICT), 2014, : 457 - 461
  • [5] Smartphone-based quantitative measurements on holographic sensors
    Moghaddam, Gita Khalili
    Lowe, Christopher Robin
    [J]. PLOS ONE, 2017, 12 (11):
  • [6] Logistic Model Tree for Human Activity Recognition Using Smartphone-Based Inertial Sensors
    Nematallah, H.
    Rajan, S.
    Cretu, A. -M.
    [J]. 2019 IEEE SENSORS, 2019,
  • [7] Towards smartphone-based touchless fingerprint recognition
    Parmeshwar Birajadar
    Meet Haria
    Pranav Kulkarni
    Shubham Gupta
    Prasad Joshi
    Brijesh Singh
    Vikram Gadre
    [J]. Sādhanā, 2019, 44
  • [8] Efficient features for smartphone-based iris recognition
    Vyas, Ritesh
    Kanumuri, Tirupathiraju
    Sheoran, Gyanendra
    Dubey, Pawan
    [J]. TURKISH JOURNAL OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCES, 2019, 27 (03) : 1589 - 1602
  • [9] Smartphone-Based Escalator Recognition for the Visually Impaired
    Nakamura, Daiki
    Takizawa, Hotaka
    Aoyagi, Mayumi
    Ezaki, Nobuo
    Mizuno, Shinji
    [J]. SENSORS, 2017, 17 (05)
  • [10] Towards smartphone-based touchless fingerprint recognition
    Birajadar, Parmeshwar
    Haria, Meet
    Kulkarni, Pranav
    Gupta, Shubham
    Joshi, Prasad
    Singh, Brijesh
    Gadre, Vikram
    [J]. SADHANA-ACADEMY PROCEEDINGS IN ENGINEERING SCIENCES, 2019, 44 (07):