Biomechanical evaluation of an expansive pedicle screw in calf vertebrae

被引:3
|
作者
雷伟
吴子祥
机构
[1] Department of Orthopaedics
[2] Xijing Hospital
[3] Xi'an
[4] China
[5] Xi'an
关键词
D O I
暂无
中图分类号
R687.3 [骨骼手术];
学科分类号
摘要
Objective: To obtain a comprehensive understanding of the effect of the improvement of fixation strength of a newly designed expansive pedicle screw through biomechanical analyses.Metheds: 100 (200 pedicles) fresh calf lumber vertebrae were used. A total of four instrumentation systems were tested including CDH (CD Horizon), USS (Universal Spine System pedicle screw), Tenor (Sofamor Denek) and expansive pedicle screw (EPS). Pullout and turning-back tests were performed to compare the holding strength of the expansive pedicle screw with conventional screws, i.e. USS, CDH and Tenor. Revision tests were performed to evaluate the mechanical properties of the expansive pedicle screw as a ”rescue” revision screw. A fatigue simulation using perpendicular load up to 1 500 000 cycles was carried out.Results: The turning back torque (Tmax) and pull-out force (Fmax) of EPS were significantly greater than those of USS, Tenor and CDH screws ( 6.5 mm×40 mm). In revision tests, the Fmax of both kinds of EPS ( 6.5 mm×40 mm; 7.0 mm×40 mm) were greater than that of CDH, USS and Tenor screws significantly (P< 0.05). No screws were broken or bent at the end of fatigue tests.Conclusions: EPS can significantly improve the bone purchase and the pull-out strength compared to USS, Tenor and CDH screws with similar dimensions before and after failure simulation. The fatigue characteristic of EPS is similar to that of CDH, USS and Tenor screws.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Biomechanical evaluation of an expansive pedicle screw in calf vertebrae
    Lei, W
    Wu, ZX
    EUROPEAN SPINE JOURNAL, 2006, 15 (03) : 321 - 326
  • [2] Biomechanical evaluation of an expansive pedicle screw in calf vertebrae
    Wei Lei
    Zixiang Wu
    European Spine Journal, 2006, 15 : 321 - 326
  • [3] Biomechanical evaluation of an expansive pedicle screw in calf vertebrae
    雷伟
    吴子祥
    中华创伤杂志(英文版), 2005, (01) : 40 - 46
  • [4] Biomechanical evaluation of monosegmental pedicle instrumentation in a calf spine model and the role of fractured vertebrae in screw stability
    Fuxin Wei
    Zhiyu Zhou
    Le Wang
    Shaoyu Liu
    Rui Zhong
    Xizhe Liu
    Shangbin Cui
    Ximin Pan
    Manman Gao
    Yajing Zhao
    BMC Veterinary Research, 12
  • [5] Biomechanical evaluation of monosegmental pedicle instrumentation in a calf spine model and the role of fractured vertebrae in screw stability
    Wei, Fuxin
    Zhou, Zhiyu
    Wang, Le
    Liu, Shaoyu
    Zhong, Rui
    Liu, Xizhe
    Cui, Shangbin
    Pan, Ximin
    Gao, Manman
    Zhao, Yajing
    BMC VETERINARY RESEARCH, 2016, 12
  • [6] Comparison of Expansive Pedicle Screw and Polymethylmethacrylate-Augmented Pedicle Screw in Osteoporotic Sheep Lumbar Vertebrae: Biomechanical and Interfacial Evaluations
    Liu, Da
    Zhang, Yi
    Zhang, Bo
    Xie, Qing-yun
    Wang, Cai-ru
    Liu, Jin-biao
    Liao, Dong-fa
    Jiang, Kai
    Lei, Wei
    Pan, Xian-ming
    PLOS ONE, 2013, 8 (09):
  • [7] Biomechanical evaluation of a double-threaded pedicle screw in elderly vertebrae
    Mummaneni, PV
    Haddock, SM
    Liebschner, MAK
    Keaveny, TM
    Rosenberg, WS
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2002, 15 (01): : 64 - 68
  • [8] Biomechanical evaluation and preliminary clinical experience with an expansive pedicle screw design
    Cook, SD
    Salkeld, SL
    Whitecloud, TS
    Barbera, J
    JOURNAL OF SPINAL DISORDERS, 2000, 13 (03): : 230 - 236
  • [9] Biomechanical comparison of different techniques in primary spinal surgery in osteoporotic cadaveric lumbar vertebrae: expansive pedicle screw versus polymethylmethacrylate-augmented pedicle screw
    Liu, Da
    Wu, Zi-xiang
    Pan, Xian-ming
    Fu, Suo-chao
    Gao, Ming-xuan
    Shi, Lei
    Lei, Wei
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2011, 131 (09) : 1227 - 1232
  • [10] Biomechanical comparison of different techniques in primary spinal surgery in osteoporotic cadaveric lumbar vertebrae: expansive pedicle screw versus polymethylmethacrylate-augmented pedicle screw
    Da Liu
    Zi-xiang Wu
    Xian-ming Pan
    Suo-chao Fu
    Ming-xuan Gao
    Lei Shi
    Wei Lei
    Archives of Orthopaedic and Trauma Surgery, 2011, 131 : 1227 - 1232