Final report, ongoing key comparison BIPM.QM-K1, ozone at ambient level, comparison with LNE, March 2023

被引:1
|
作者
Viallon J. [1 ]
Idrees F. [1 ]
Moussay P. [1 ]
Wielgosz R. [1 ]
Mary F. [2 ]
Macé T. [2 ]
Sutour C. [2 ]
机构
[1] Bureau International des Poids et Mesures, Pavillon de Breteuil, Sèvres
[2] Laboratoire National de Métrologie et d'Essais
关键词
Compilation and indexing terms; Copyright 2025 Elsevier Inc;
D O I
10.1088/0026-1394/60/1A/08018
中图分类号
学科分类号
摘要
Main text As part of the ongoing key comparison BIPM.QM-K1, a comparison has been performed between the ozone national standard of France maintained by the Laboratoire National de métrologie et d'Essais (LNE) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM). The instruments have been compared over a nominal ozone amount fraction range of 0 nmol mol-1 to 500 nmol mol-1. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA). © 2023 BIPM & IOP Publishing Ltd.
引用
收藏
相关论文
共 50 条
  • [1] Final report, Ongoing Key Comparison BIPM.QM-K1, Ozone at ambient level, comparison with LNE, (May 2012)
    Viallon, Joele
    Moussay, Philippe
    Idrees, Faraz
    Wielgosz, Robert
    Mace, Tatiana
    Couette, Jerome
    METROLOGIA, 2012, 49
  • [2] Final report, Ongoing Key Comparison BIPM.QM-K1, Ozone at ambient level, comparison with KRISS, (March 2012)
    Viallon, Joele
    Moussay, Philippe
    Idrees, Faraz
    Wielgosz, Robert
    Lee, Sangil
    Lee, Jae Y.
    Woo, Jin C.
    Kim, Byung M.
    METROLOGIA, 2012, 49
  • [3] Final report, Ongoing Key Comparison BIPM.QM-K1, Ozone at ambient level, comparison with UBA, (March 2012)
    Viallon, Joele
    Moussay, Philippe
    Idrees, Faraz
    Wielgosz, Robert
    Stummer, Volker
    Schinz, Verena
    METROLOGIA, 2012, 49
  • [4] Final report, Ongoing Key Comparison BIPM.QM-K1, Ozone at ambient level, comparison with ISCIII, (May 2023)
    Viallon, Joële
    Moussay, Philippe
    Idrees, Faraz
    Wielgosz, Robert
    Nuñez-Corcuera, Beatriz
    Santos-Alves, Saúl Garcia Dos
    Metrologia, 2023, 60 (01)
  • [5] Final report, Ongoing Key Comparison BIPM.QM-K1, Ozone at ambient level, comparison with CHMI, 2009
    Viallon, Joele
    Moussay, Philippe
    Idrees, Faraz
    Wielgosz, Robert
    Novak, Jiri
    Vokoun, Miroslav
    METROLOGIA, 2011, 48
  • [6] Final report on ongoing key comparison BIPM.QM-K1, ozone at ambient level, comparison with NIM (July 2014)
    Viallon, Joele
    Moussay, Philippe
    Idrees, Faraz
    Wielgosz, Robert
    Zhou, Zeyi
    METROLOGIA, 2015, 52
  • [7] Final report, Ongoing Key Comparison BIPM.QM-K1, Ozone at ambient level, comparison with VSL, (December 2010)
    Viallon, Joele
    Moussay, Philippe
    Idrees, Faraz
    Wielgosz, Robert
    Heikens, Dita
    Wessel, Rob
    METROLOGIA, 2011, 48
  • [8] Final report, Ongoing Key Comparison BIPM.QM-K1, Ozone at ambient level, comparison with NMISA, (July 2012)
    Viallon, Joele
    Moussay, Philippe
    Idrees, Faraz
    Wielgosz, Robert
    Botha, Angelique
    METROLOGIA, 2013, 50
  • [9] Final report, ongoing key comparison BIPM.QM-K1, ozone at ambient level, comparison with CHMI, September 2021
    Viallon J.
    Idrees F.
    Moussay P.
    Wielgosz R.
    Vokoun M.
    Metrologia, 2022, 59 (1 A)
  • [10] Final report, ongoing key comparison BIPM.QM-K1, ozone at ambient level, comparison with INRIM, February 2022
    Viallon J.
    Idrees F.
    Moussay P.
    Wielgosz R.
    Revel L.
    Zucco M.
    Metrologia, 2022, 59 (1 A)