Current Sensorless Pole-Zero Cancellation Output Voltage Control for Uninterruptible Power Supply Systems with a Three-Phase Inverter

被引:0
|
作者
Lee, Hosik [1 ]
Kim, Yonghun [2 ]
Kim, Seok-Kyoon [3 ]
机构
[1] Tenergy, Green Mobil Team, Suwon 18487, South Korea
[2] Chungnam Natl Univ, Sch Mech Engn, Daejeon 34134, South Korea
[3] Hanbat Natl Univ, Dept Creat Convergence Engn, Daejeon 34158, South Korea
关键词
uninterruptible power supply; voltage control; observer; active damping; pole-zero cancellation; MODEL-PREDICTIVE CONTROL; UPS; ALGORITHM; DESIGN; SINGLE; FILTER;
D O I
10.3390/en17071738
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This article presents a proportional-derivative (PD) type output voltage regulator without the current feedback, taking into account system parameter and load variations. The main advantages are given as follows: First, the first-order output voltage derivative observer is developed without the requirement of system parameter information, which makes it possible to stabilize the system without current sensing. Second, a simple self-tuner implements the feedback-loop adaptation by updating the desired dynamics accordingly. Third, the observer-based active damping injection for the PD-type controller results in the closed-loop system order reduction to 1 by the pole-zero cancellation, including the disturbance observer as a feed-forward term. The prototype uninterruptible power supply system comprised of a 3 kW three-phase inverter, inductors, and capacitors verifies the practical merits of the proposed technique for linear and nonlinear loads.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] Adaptive fuzzy control for uninterruptible power supply with three-phase PWM inverter
    Hsu, FY
    Fu, LC
    [J]. SOFT COMPUTING IN INTELLIGENT SYSTEMS AND INFORMATION PROCESSING, 1996, : 188 - 193
  • [2] Disturbance-observer-based model predictive control for output voltage regulation of three-phase inverter for uninterruptible-power-supply applications
    Kim, Seok-Kyoon
    Park, Chang Reung
    Yoon, Tae-Woong
    Lee, Young Il
    [J]. EUROPEAN JOURNAL OF CONTROL, 2015, 23 : 71 - 83
  • [3] Digital control of three-phase series-parallel uninterruptible power supply systems
    Nasiri, Adel
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2007, 22 (04) : 1116 - 1127
  • [5] Feedforward Control of Output Current for Three-Phase Voltage Source Inverter (VSI) with Transformer
    Qi, Yu
    Peng, Li
    Huang, Zeyi
    Chen, Manlin
    Sun, Lei
    [J]. 2014 TWENTY-NINTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC), 2014, : 2318 - +
  • [6] Hybrid learning control strategy for three-phase uninterruptible power supply
    Niroomand, M.
    Karshenas, H. R.
    [J]. IET POWER ELECTRONICS, 2011, 4 (07) : 799 - 807
  • [7] An effective pole-zero cancellation in feedforward controllers for nonminimum phase systems
    Choi, BK
    Choi, CH
    [J]. PROCEEDINGS OF THE 1997 AMERICAN CONTROL CONFERENCE, VOLS 1-6, 1997, : 3907 - 3908
  • [8] Zero Sequence Astatic Control of Three-Phase Four-Leg Voltage Source Inverter of Power Supply System
    Kharitonov, Sergey A.
    Kharitonov, Audrey S.
    Khristolyubova, Alexandra, I
    Bukina, Elena Ya
    Bakhovtsev, Igor A.
    [J]. 2020 1ST INTERNATIONAL CONFERENCE PROBLEMS OF INFORMATICS, ELECTRONICS, AND RADIO ENGINEERING (PIERE), 2020, : 136 - 144
  • [9] A novel three-phase zero current transition voltage source inverter
    Cosan, M
    Boroyevich, D
    Lee, FC
    [J]. POWER ELECTRONICS IN TRANSPORTATION, 1996, : 227 - 232
  • [10] Inverter output voltage control of three-phase UPS systems using feedback linearization
    Kim, Dong-Eok
    Lee, Dong-Choon
    [J]. IECON 2007: 33RD ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOLS 1-3, CONFERENCE PROCEEDINGS, 2007, : 1737 - 1742