Topology and parameter design of power supply quality comprehensive improvement device for highly sensitive users

被引:0
|
作者
Hu W. [1 ]
Shen Y. [1 ]
Li X. [1 ]
Yang F. [1 ]
Yang Z. [1 ]
Zuo W. [2 ]
机构
[1] Electric Power Research Institute, State Grid Hubei Electric Power Co., Ltd., Wuhan
[2] School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan
关键词
Comprehensive improvement; Parameter design; Power supply quality; Redundancy; Topology structure;
D O I
10.16081/j.epae.202006014
中图分类号
学科分类号
摘要
In order to meet the high demand of power supply quality for large capacity and highly sensitive users, a topology structure of cascade H-bridge with energy storage and source-load isolation and a design method of key parameters considering the redundancy of cascade H-bridge are proposed. A set of power supply quality improvement device with the capacity of 1 MV•A for highly sensitive users is developed. Based on power grid simulator, the device performance test platform is built to test the output performance of the device in case of various power supply quality events. The test results show that the proposed topo-logy can automatically realize seamless switching between power grid and energy storage power supply, and provide an effective method for improving the comprehensive power supply quality of highly sensitive users. The proposed parameter design method can reduce the number of energy storage inputs and extend the energy storage life. © 2020, Electric Power Automation Equipment Press. All right reserved.
引用
收藏
页码:219 / 224
页数:5
相关论文
共 15 条
  • [1] TANG Shun, TANG Songhao, CHEN Cong, Et al., Experimental research on adjustable speed drivers tolerance to voltage sags and quantitative method part Ⅰ: mechanism analysis and test method, Transactions of China Electrotechnical Society, 34, 6, pp. 1276-1281, (2019)
  • [2] XU Yongmei, LAN Qiaoqian, HONG Wangsong, Experimental research on AC contactor sensitivity during voltage sags, Transactions of China Electrotechnical Society, 30, 21, pp. 136-146, (2015)
  • [3] JIANG Chenyang, LIU Qing, LIANG Xiao, Control variable pai-ring and coordinated commissioning for multiple FACTS components, Electric Power Automation Equipment, 37, 4, pp. 179-184, (2017)
  • [4] XU Dezhi, WANG Fei, RUAN Yi, Passive damping of LCL, LLCL and LLCCL filters, Proceedings of the CSEE, 35, 18, pp. 4725-4735, (2015)
  • [5] LIU Huadong, ZHANG Dinghua, TANG Jianyu, Et al., Research on direct voltage control of STATCOM for mitigating electric arc furnaces flicker, Transactions of China Electrotechnical Society, 27, 9, pp. 41-47, (2012)
  • [6] MI Yang, MA Chao, FU Yang, Et al., Design of SVC sliding mode compensation controller in isolated wind-diesel hybrid power system based on sliding mode observer, Power System Technology, 41, 1, pp. 178-186, (2017)
  • [7] ZHOU Wu, LE Jian, YANG Jintao, Et al., Control strategy of MV dynamic voltage restorer as virtual impedance, Power System Technology, 40, 8, pp. 2525-2532, (2016)
  • [8] MAHDIANPOOR F M, HOOSHMAND R A, ATAEI M., A new approach to multifunctional dynamic voltage restorer implemen-tation for emergency control in distribution systems, IEEE Transactions on Power Delivery, 26, 2, pp. 882-890, (2011)
  • [9] LU Zhipeng, WU Ming, SONG Zhenhao, Et al., Comparative analysis of high-order passive filters, Electric Power Automation Equipment, 39, 6, pp. 54-60, (2019)
  • [10] CHEN Jikai, MA Xiuwei, LI Jiang, Et al., Analysis on interaction of two-parallel APF, Power System Technology, 41, 3, pp. 956-961, (2017)