Experimental evaluation of a heat exchanger for different configurations between internal and external flow

被引:0
|
作者
Ramirez-Dolores, C. [1 ]
Andaverde, J. [2 ]
Ordonez-Castillo, L. [3 ]
Wong-Loya, J. [4 ]
机构
[1] Univ Nacl Autonoma Mexico, Posgrad Ingn, Inst Energias Renovables, Priv Xochicalco S-N, Temixco 62580, Morelos, Mexico
[2] Univ Veracruzana, Fac Ciencias Quim, Coatzacoalcos 96538, Veracruz, Mexico
[3] Univ Nacl Autonoma Mexico, Licenciatura Ingn Energias Renovables, Inst Energias Renovables, Priv Xochicalco S-N, Temixco 62580, Morelos, Mexico
[4] Univ Nacl Autonoma Mexico, Inst Energias Renovables, Priv Xochicalco S-N, Temixco 62580, Morelos, Mexico
关键词
Fluid flow; Air-water heat exchanger; NTU-epsilon; Heat exchanger positions; THERMAL PERFORMANCE; NUMERICAL EVALUATION; AIR-QUALITY; EARTH; COMFORT; DESIGN; ENERGY; GROUNDWATER; BUILDINGS; EQUATION;
D O I
10.1007/s41939-024-00460-0
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In the present work, the determination of the thermal effectiveness and temperature of the air at the outlet of a scale prototype of a heat exchanger immersed in flowing water was developed experimentally. This depended on the position of the working fluid (air) and of the heat exchanger positioning configuration. The tested positions were parallel flow, quasi-parallel oblique, counterflow, quasi-counterflow oblique, and crossflow. The temperature of the air at the outlet of the heat exchanger and the thermal effectiveness are essential to determine the most convenient operating position of these systems, especially those related to shallow geothermal energy. The thermohydraulic aspects of the heat exchanger presented were evaluated, by the Number of Transfer Units-Effectiveness (NTU-epsilon) method, under conditions of water flow in a natural channel and air flow induced by a blower, the system was built from commercial copper pipe and temperature sensors were placed in both the exchanger and the water to record temperature changes. The results of this study indicate that when the exchanger is positioned in the oblique quasi-counterflow position and the oblique quasi-parallel position, it exhibits the lowest air outlet temperatures and highest thermal effectiveness, which is relevant for building cooling applications.
引用
收藏
页码:4117 / 4132
页数:16
相关论文
共 50 条
  • [1] Experimental investigation and performance evaluation of a mixed-flow air to air membrane enthalpy exchanger with different configurations
    Albdoor, Ahmed K.
    Ma, Zhenjun
    Cooper, Paul
    APPLIED THERMAL ENGINEERING, 2020, 166
  • [2] Performance evaluation of parallel flow microchannel heat exchanger subjected to external heat transfer
    Mathew, B.
    Hegab, H.
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION 2007, VOL 8, PTS A AND B: HEAT TRANSFER, FLUID FLOWS, AND THERMAL SYSTEMS, 2008, : 941 - 949
  • [3] A comprehensive experimental analysis for optimal flow configurations in a triple tube heat exchanger (TTHXr)
    Yadav, Devendra
    Kushwaha, Akhilesh
    Trivedee, Divakar
    Upadhyay, Zenis
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2022, 138
  • [4] HEAT-EXCHANGER FLOW CONFIGURATIONS - DIMENSIONAL ANALYSIS
    LELLI, U
    CHEMICAL ENGINEERING SCIENCE, 1991, 46 (08) : 1945 - 1950
  • [5] Evaluation of storage configurations with internal heat exchangers
    Dahm, J
    Bales, C
    Lorenz, K
    Dalenback, JO
    SOLAR ENERGY, 1998, 62 (06) : 407 - 417
  • [6] Study on Flow and Heat Transfer Characteristics in Lamilloy Structure with Different Configurations of Internal Minichannels
    Yang, Tao
    Zhang, Xiaoming
    Chang, Zhenyuan
    Xu, Liang
    Xi, Lei
    Gao, Jianmin
    Kou, Wei
    Jing, Xiaochun
    ENERGIES, 2023, 16 (24)
  • [7] Material flow characteristics in the integrated external heat exchanger
    Xiong, Bin
    Lu, Xiao-Feng
    Liu, Han-Zhou
    Dongli Gongcheng/Power Engineering, 2008, 28 (06): : 850 - 855
  • [8] Numerical and Experimental Investigation of Flow and Heat Transfer in Heat Exchanger Channels with Different Dimples Geometries
    Ying, Pingting
    He, You
    Tang, Hesheng
    Ren, Yan
    MACHINES, 2021, 9 (04)
  • [9] EXPERIMENTAL PERFORMANCE EVALUATION OF COMBI-HEATERS WITH DIFFERENT HEAT EXCHANGER UNITS
    Koseoglu, Mehmet Fevzi
    Baskaya, Senol
    Calisir, Tamer
    JOURNAL OF THE FACULTY OF ENGINEERING AND ARCHITECTURE OF GAZI UNIVERSITY, 2015, 30 (01): : 29 - 37
  • [10] Experimental investigation of internal and external flow fields of jetting nozzles with different structures
    Jiang, Tianwen
    Huang, Zhongwei
    Li, Jingbin
    Zhou, Yisu
    Xiong, Chao
    JOURNAL OF PETROLEUM SCIENCE AND ENGINEERING, 2022, 217