Validity and reliability of inertial measurement units used to measure motion of the lumbar spine: A systematic review of individuals with and without low back pain

被引:7
|
作者
Mcclintock, Frederick A. [1 ]
Callaway, Andrew J. [1 ]
Clark, Carol J. [1 ]
Williams, Jonathan M. [1 ]
机构
[1] Bournemouth Univ, Fac Hlth & Social Sci, Poole BH12 5BB, England
关键词
Low back; Pain; Sensors; Review; Biomechanics; CONCURRENT VALIDITY; GLOBAL BURDEN; KINEMATICS; ORIENTATION; PREVALENCE; DISEASE; QUALITY; STAND; TORSO; GAIT;
D O I
10.1016/j.medengphy.2024.104146
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Low back pain (LBP) is a leading cause of disability, resulting in aberrant movement. This movement is difficult to measure accurately in clinical practice and gold standard methods, such as optoelectronic systems involve the use of expensive laboratory equipment. Inertial measurement units (IMU) offer an alternative method of quantifying movement that is accessible in most environments. However, there is no consensus around the validity and reliability of IMUs for quantifying lumbar spine movements compared with gold standard measures. The aim of this systematic review was to establish concurrent validity and repeated measures reliability of using IMUs for the measurement of lumbar spine movements in individuals with and without LBP. A systematic search of electronic databases, incorporating PRISMA guidelines was completed, limited to the English language. 503 studies were identified where 15 studies met the inclusion criteria. Overall, 305 individuals were included, and 109 of these individuals had LBP. Weighted synthesis of the results demonstrated root mean squared differences of <2.4 degrees compared to the gold standard and intraclass correlations >0.84 for lumbar spine movements. IMUs offer clinicians and researchers valid and reliable measurement of motion in the lumbar spine, comparable to laboratory methods, such as optoelectronic motion capture for individuals with and without LBP.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Reliability of a Measure of Total Lumbar Spine Range of Motion in Individuals with Low Back Pain
    Al Zoubi, Fadi M.
    Preuss, Richard A.
    JOURNAL OF APPLIED BIOMECHANICS, 2013, 29 (06) : 670 - 677
  • [2] The measurement of lumbar proprioception in individuals with and without low back pain
    Gill, KP
    Callaghan, MJ
    SPINE, 1998, 23 (03) : 371 - 377
  • [3] Validity of inertial measurement units for tracking human motion: a systematic review
    Ghattas, John
    Jarvis, Danielle N.
    SPORTS BIOMECHANICS, 2021,
  • [4] VALIDITY AND RELIABILITY OF INERTIAL MEASUREMENT UNITS FOR JUMP HEIGHT ESTIMATIONS: A SYSTEMATIC REVIEW
    Clemente, Filipe Manuel
    Badicu, Georgian
    Hasan, Uday Ch.
    Akyildiz, Zeki
    Pino-Ortega, Jose
    Silva, Rui
    Rico-Gonzalez, Markel
    HUMAN MOVEMENT, 2022, 23 (04) : 1 - 20
  • [5] INTEREXAMINER RELIABILITY AND DISCRIMINANT VALIDITY OF INCLINOMETRIC MEASUREMENT OF LUMBAR ROTATION IN CHRONIC LOW-BACK-PAIN PATIENTS AND SUBJECTS WITHOUT LOW-BACK-PAIN
    BOLINE, PD
    KEATING, JC
    HAAS, M
    ANDERSON, AV
    SPINE, 1992, 17 (03) : 335 - 338
  • [6] The reliability of pressure pain threshold in individuals with low back or neck pain: a systematic review
    Bhattacharyya, Anit
    Hopkinson, Lily D.
    Nolet, Paul S.
    Srbely, John
    BRITISH JOURNAL OF PAIN, 2023, 17 (06) : 579 - 591
  • [7] Measurement of Lumbar Spine Functional Movement in Low Back Pain
    Vaisy, Morad
    Gizzi, Leonardo
    Petzke, Frank
    Consmueller, Tobias
    Pfingsten, Michael
    Falla, Deborah
    CLINICAL JOURNAL OF PAIN, 2015, 31 (10): : 876 - 885
  • [8] The Kinematics and Spondylosis of the Lumbar Spine Vary Depending on the Levels of Motion Segments in Individuals With Low Back Pain
    Basques, Bryce A.
    Orias, Alejandro A. Espinoza
    Shifflett, Grant D.
    Fice, Michael P.
    Andersson, Gunnar B.
    An, Howard S.
    Inoue, Nozomu
    SPINE, 2017, 42 (13) : E767 - E774
  • [9] Thoracolumbar proprioception in individuals with and without low back pain: Intratester reliability, clinical applicability, and validity
    Koumantakis, GA
    Winstanley, J
    Oldham, JA
    JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2002, 32 (07): : 327 - 335
  • [10] The reliability and concurrent validity of a new iPhone® application for measuring active lumbar spine flexion and extension range of motion in patients with low back pain
    Pourahmadi, Mohammadreza
    Momeni, Elnaz
    Mohseni, Negar
    Hesarikia, Hamid
    Ghanjal, Ali
    Shamsoddini, Alireza
    PHYSIOTHERAPY THEORY AND PRACTICE, 2021, 37 (01) : 204 - 217