Effect of Cyclic Clogging-Cleaning on Water Permeability of Porous Asphalt Mixture

被引:0
|
作者
Zhu X. [1 ]
Li B. [1 ,2 ]
Wei D. [1 ,3 ]
Wen W. [2 ]
Zhou J. [1 ]
机构
[1] Key Laboratory of Road & Bridge and Underground Engineering of Gansu Province, Lanzhou Jiaotong University, Lanzhou
[2] National and Provincial Joint Engineering Laboratory of Road & Bridge Disaster Prevention and Control, Lanzhou Jiaotong University, Lanzhou
[3] Gansu Province Transportation Planning, Survey & Design Institute Co., Ltd., Lanzhou
来源
| 1600年 / Cailiao Daobaoshe/ Materials Review卷 / 34期
基金
中国国家自然科学基金;
关键词
Cleaning method; Cyclic clogging-cleaning; Permeability; Porous asphalt mixture; Road engineering;
D O I
10.11896/cldb.19100083
中图分类号
学科分类号
摘要
In order to study the anti-clogging performance of porous asphalt pavement, the porous asphalt concrete (PAC) was clogged with aeolian sand as a clogging material, and the PAC specimens after each clogging were cleaned by manual brushing, vacuum pumping and high-pressure water washing. The permeability of each specimen after clogging and cleaning was measured using falling-head permeability setup. The effect of air voids, nominal maximum aggregate size and cleaning method on the permeability of PAC under the condition of cyclic clogging-clea-ning was investigated. Based on this, the clogging sensitive particles of PAC-13 were studied. The results show that the values of permeability kC after clogging and permeability after cleaning kR decrease rapidly and then gradually stabilize as the number of loadings increases. The anti-clogging performance and recovery effect of permeability of PAC increases with the increase of air void and nominal maximum aggregate size. The residual rate of water permeability of PAC specimens with different air void was significantly different, and the γ value of PAC specimens with larger air void was larger under the same cycle number. The cleaning effect was ranked as high-pressure water washing > vacuum pumping> manual brushing. Particles with the size range of 0.15-2.36 mm are the key particle sizes that cause the clogging of PAC-13 specimen, the particle size of PAC-13 clogging sensitive particle gradually increases with the increase of air void. © 2020, Materials Review Magazine. All right reserved.
引用
收藏
页码:20040 / 20045
页数:5
相关论文
共 33 条
  • [1] Sha Aimin, Jiang Wei, China Journal of Highway and Transport, 31, 9, (2018)
  • [2] Chu L, Fwa T F., Construction and Building Materials, 197, (2019)
  • [3] Skarabis J, Stockert U., Journal of Traffic and Transportation Engineering, 2, 2, (2015)
  • [4] Pei Jianzhong, Zhang Jialin, Chang Mingfeng, Et al., China Journal of Highway and Transport, 23, 1, (2010)
  • [5] Zhou Wei, Huang Xiaoming, Liang Yanlong, Et al., Journal of Chang'an University (Natural Science Edition), 36, 1, (2016)
  • [6] Nichols P W B, White R, Lucke T., Science of the Total Environment, 511, (2015)
  • [7] Moriyoshi A, Jin T, Nakai T, Et al., Construction and Building Mate-rials, 42, (2013)
  • [8] Abdullah N A M, Hassan N A, Shukry N A M, Et al., Jurnal Teknologi, 78, (2016)
  • [9] Deo O, Sumanasooriya M, Neithalath N., Journal of Materials in Civil Engineering, 22, 7, (2010)
  • [10] Jiang Wei, Sha Aimin, Xiao Jingjing, Et al., Journal of Tongji University (Natural Science), 43, 1, (2015)