Application of an in-house developed complementary metal-oxide-semiconductor-based optical computed tomography (CMOS-OCT) imaging system for stereotactic radiosurgery dosimetry using a PRESAGE® dosimeter

被引:3
|
作者
Zin H.M. [1 ]
Abdul Rahman A.T. [2 ,3 ,4 ]
机构
[1] Advanced Medical and Dental Institute, Universiti Sains Malaysia, Penang, Bertam
[2] College of Sciences, King Saud University, Riyadh
[3] Institute of Science, University Teknologi MARA, Selangor, Shah Alam
[4] Faculty of Applied Sciences, University Teknologi MARA, Selangor, Shah Alam
来源
关键词
Complementary metal-oxide-semiconductor; Optical computed tomography; PRESAGE®; Three-dimensional radiation dosimeter;
D O I
10.1016/j.radphyschem.2022.110029
中图分类号
学科分类号
摘要
PRESAGE® dosimeter can be useful for 3D verification of radiotherapy treatment delivery when careful attention is given to the dosimeter measurement technique. Ideally, a low noise and fast optical CT scanning system is required for imaging the dosimeter for verification of advanced radiotherapy treatment delivery. We have developed a complementary metal-oxide-semiconductor (CMOS)-based optical computed tomography (OCT) system (CMOS-OCT), implementing the recent advances in CMOS active pixel sensor (APS) technology that offer on-chip image processing and high-speed readout. In this study, we present the dosimetric response of irradiated PRESAGE® dosimeter measured with the CMOS-OCT system and describe a feasibility study of using the calibrated system to verify stereotactic radiosurgery (SRS) treatment. PRESAGE® dosimeters were irradiated using a 6 MV Elekta Synergy linear accelerator to investigate dosimetric and geometric properties of PRESAGE® dosimeter with CMOS-OCT imaging system, in order to verify a clinical SRS treatment plan of the brain. The tomographic projection images of the PRESAGE® dosimeter were captured by the image sensor within 100 s for a 360-degree rotation. The CMOS-OCT imaging system showed good linearity in dose-response measured by PRESAGE® dosimeter. The correlation of the optical density (OD) changes measured from the CMOS-OCT with attenuation value measured using a calibrated UV/Vis spectrophotometer was found to be better than 0.996. The tomographic reconstruction of the dose distribution from the PRESAGE® showed good agreement when compared with the calculated dose distributions from the treatment planning software. The in-house CMOS-OCT imaging system is capable of visualising and verifying the dose distribution of stereotactic radiosurgery treatment. The CMOS-OCT imaging of the PRESAGE® dosimeter provides accurate dosimetric and geometric information on radiotherapy delivery in a three-dimensional volume, which is useful in advanced radiotherapy. The introduction of CMOS technology in the OCT improves the imaging speed of the dosimeters dose readout. © 2022 Elsevier Ltd
引用
收藏
相关论文
共 2 条
  • [1] Development of a CMOS-based optical computed tomography system (CMOS-OCT) for 3D radiotherapy dosimetry
    Rosli N.F.
    Zin H.M.
    Rahman A.T.A.
    [J]. Health and Technology, 2018, 8 (3) : 189 - 196
  • [2] Imaging particles in solid/air flows using an optical tomography system based on complementary metal oxide semiconductor area image sensors
    Idroas, M.
    Najib, S. M.
    Ibrahim, M. N.
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2015, 220 : 75 - 80