Point-of-care blood tests using a smartphone-based colorimetric analyzer for health check-up

被引:3
|
作者
Chunta, Suticha [1 ]
Jarujamrus, Purim [2 ,3 ,7 ]
Prakobkij, Akarapong [2 ,3 ]
Khongwichit, Soemwit [1 ,4 ]
Ditcharoen, Nadh [5 ]
Pencharee, Somkid [6 ]
Amatatongchai, Maliwan [2 ,3 ]
机构
[1] Prince Songkla Univ, Fac Med Technol, Dept Clin Chem, Hat Yai 90110, Thailand
[2] Ubon Ratchathani Univ, Fac Sci, Ctr Excellence Innovat Chem, Dept Chem, Ubon Ratchathani 34190, Thailand
[3] Ubon Ratchathani Univ, Fac Sci, Nanomat Sci Sensors & Catalysis Problem Based Proj, Ubon Ratchathani 34190, Thailand
[4] Prince Songkla Univ, Fac Sci, Div Biol Sci, Hat Yai 90110, Thailand
[5] Ubon Ratchathani Univ, Fac Sci, Dept Math Stat & Comp, Ubon Ratchathani 34190, Thailand
[6] Ubon Ratchathani Univ, Fac Sci, Dept Phys, Ubon Ratchathani 34190, Thailand
[7] Keio Univ, Fac Sci & Technol, Dept Appl Chem, 3-14-1 Hiyoshi,Kohoku Ku, Yokohama 2238522, Japan
关键词
Point-of-care blood test; Health checkup; Colorimetric assay; Smartphone application; SYSTEM; CHOLESTEROL; DEVICES; ASSAYS; SERUM;
D O I
10.1007/s00604-024-06463-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A microscale colorimetric assay was designed and implemented for the simultaneous determination of clinical chemistry tests measuring six parameters, including glucose (GLU), total protein (TP), human serum albumin (HSA), uric acid (UA), total cholesterol (TC), and triglycerides (TGs) in plasma samples. The test kit was fabricated using chromogenic reagents, comprising specific enzymes and binding dyes. Multiple colors that appeared on the reaction well when it was exposed to each analyte were captured by a smartphone and processed by the homemade Check6 application, which was designed as a colorimetric analyzer and simultaneously generated a report that assessed test results against gender-dependent reference ranges. Six blood checkup parameters for four plasma samples were conducted within 12 min on one capture picture. The assay achieved wide working concentration ranges of 10.45-600 mg dL(-1) GLU, 1.39-10.0 g dL(-1) TP, 1.85-8.0 g dL(-1) HSA, 0.86-40.0 mg dL(-1) UA, 11.28-600 mg dL(-1) TC, and 11.93-400 mg dL(-1) TGs. The smartphone-based assay was accurate with recoveries of 93-108% GLU, 93-107% TP, 92-107% HSA, 93-107% UA, 92-107% TC, and 99-113% TGs. The coefficient of variation for intra-assay and inter-assay precision ranged from 3.2-5.2% GLU, 4.6-5.3% TP, 4.3-5.3% HSA, 2.8-6.6% UA, 2.7-6.5% TC, and 1.1-3.9% TGs. This assay demonstrated remarkable accuracy in quantifying the concentration-dependent color intensity of the plasma, even in the presence of other suspected interferences commonly present in serum. The results of the proposed method correlated well with results determined by the microplate spectrophotometer (R-2 > 0.95). Measurement of these six clinical chemistry parameters in plasma using a microscale colorimetric test kit coupled with the Check6 smartphone application showed potential for real-time point-of-care analysis, providing cost-effective and rapid assays for health checkup testing.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] A smartphone-based diagnostic analyzer for point-of-care milk somatic cell counting
    Sun, Xiaoyun
    Zhao, Ruiming
    Wang, Xianhua
    Wu, Yunlong
    Yang, Degang
    Wang, Jianhui
    Wu, Zhihong
    Wang, Nan
    Zhang, Juan
    Xiao, Bin
    Chen, Jiaci
    Huang, Fengchun
    Chen, Ailiang
    ANALYTICA CHIMICA ACTA, 2024, 1304
  • [2] Smartphone-based polydiacetylene colorimetric sensor for point-of-care diagnosis of bacterial infections
    Zhou Y.
    Xue Y.
    Lin X.
    Duan M.
    Hong W.
    Geng L.
    Zhou J.
    Fan Y.
    Smart Materials in Medicine, 2024, 5 (01): : 140 - 152
  • [3] Advances in Smartphone-Based Point-of-Care Diagnostics
    Xu, Xiayu
    Akay, Altug
    Wei, Huilin
    Wang, ShuQi
    Pingguan-Murphy, Belinda
    Erlandsson, Bjoern-Erik
    Li, XiuJun
    Lee, WonGu
    Hu, Jie
    Wang, Lin
    Xu, Feng
    PROCEEDINGS OF THE IEEE, 2015, 103 (02) : 236 - 247
  • [4] Point-of-Care Smartphone-based Electrochemical Biosensing
    Sun, Alexander C.
    Hall, Drew A.
    ELECTROANALYSIS, 2019, 31 (01) : 2 - 16
  • [5] Point-of-care applications of smartphone-based microscopy
    Ayardulabi, Reyhaneh
    Khamespanah, Erfan
    Abbasinia, Sarv
    Ehtesabi, Hamide
    SENSORS AND ACTUATORS A-PHYSICAL, 2021, 331
  • [6] Smartphone-Based Point-of-Care Microfluidic Platform Fabricated with a ZnO Nanorod Template for Colorimetric Virus Detection
    Xia, Yiqiu
    Chen, Yizhu
    Tang, Yeming
    Cheng, Gong
    Yu, Xu
    He, Hongzhang
    Cao, Guohong
    Lu, Huaguang
    Liu, Zhiwen
    Zheng, Si-Yang
    ACS SENSORS, 2019, 4 (12) : 3298 - 3307
  • [7] Smartphone-based cytometric biosensors for point-of-care cellular diagnostics
    Shengwei Zhang
    Zheng Li
    Qingshan Wei
    NanotechnologyandPrecisionEngineering, 2020, 3 (01) : 32 - 42
  • [8] Smartphone-Based Point-of-Care Urinalysis Under Variable Illumination
    Ra, Moonsoo
    Muhammad, Mannan Saeed
    Lim, Chiawei
    Han, Sehui
    Jung, Chansung
    Kim, Whoi-Yul
    IEEE JOURNAL OF TRANSLATIONAL ENGINEERING IN HEALTH AND MEDICINE, 2018, 6
  • [9] Build-in sensors and analysis algorithms aided smartphone-based sensors for point-of-care tests
    Xia Y.
    Hu J.
    Zhao S.
    Tao L.
    Li Z.
    Yue T.
    Kong J.
    Biosensors and Bioelectronics: X, 2022, 11
  • [10] Smartphone-based cytometric biosensors for point-of-care cellular diagnostics
    Zhang, Shengwei
    Li, Zheng
    Wei, Qingshan
    NANOTECHNOLOGY AND PRECISION ENGINEERING, 2020, 3 (01) : 32 - 42