Perspectives on the comparative benefits of body-powered and myoelectric upper limb prostheses

被引:0
|
作者
Engdahl, Susannah M. [1 ]
Gonzalez, Michael A. [2 ]
Lee, Christina [1 ]
Gates, Deanna H. [1 ,2 ]
机构
[1] Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Sch Kinesiol, Ann Arbor, MI USA
关键词
Upper limb; Prosthesis; Control; Rehabilitation; Function; Myoelectric; Body-powered; UPPER EXTREMITY AMPUTEES; MOVEMENTS; STRATEGIES; USERS; COORDINATION; MOTION; ARM;
D O I
10.1186/s12984-024-01436-4
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
BackgroundPatient access to body-powered and myoelectric upper limb prostheses in the United States is often restricted by a healthcare system that prioritizes prosthesis prescription based on cost and perceived value. Although this system operates on an underlying assumption that design differences between these prostheses leads to relative advantages and disadvantages of each device, there is limited empirical evidence to support this view.Main textThis commentary article will review a series of studies conducted by our research team with the goal of differentiating how prosthesis design might impact user performance on a variety of interrelated domains. Our central hypothesis is that the design and actuation method of body-powered and myoelectric prostheses might affect users' ability to access sensory feedback and account for device properties when planning movements. Accordingly, other domains that depend on these abilities may also be affected. While our work demonstrated some differences in availability of sensory feedback based on prosthesis design, this did not result in consistent differences in prosthesis embodiment, movement accuracy, movement quality, and overall kinematic patterns.ConclusionCollectively, our findings suggest that performance may not necessarily depend on prosthesis design, allowing users to be successful with either device type depending on the circumstances. Prescription practices should rely more on individual needs and preferences than cost or prosthesis design. However, we acknowledge that there remains a dearth of evidence to inform decision-making and that an expanded research focus in this area will be beneficial.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] MYOELECTRIC AND BODY-POWERED PROSTHESES
    KRUGER, LM
    FISHMAN, S
    [J]. JOURNAL OF PEDIATRIC ORTHOPAEDICS, 1993, 13 (01) : 68 - 75
  • [2] Differences in myoelectric and body-powered upper-limb prostheses: Systematic literature review
    Carey, Stephanie L.
    Lura, Derek J.
    Highsmith, M. Jason
    [J]. JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 2015, 52 (03): : 247 - 262
  • [3] TRAUMATIC AMPUTATION OF THE UPPER LIMB - THE USE OF BODY-POWERED PROSTHESES AND EMPLOYMENT CONSEQUENCES
    STURUP, J
    THYREGOD, HC
    JENSEN, JS
    RETPEN, JB
    BOBERG, G
    RASMUSSEN, E
    JENSEN, S
    [J]. PROSTHETICS AND ORTHOTICS INTERNATIONAL, 1988, 12 (01) : 50 - 52
  • [4] Mechanical Testing Methods for Body-Powered Upper-Limb Prostheses: A Review
    Mio, Renato
    Sanchez, Midori
    Valverde, Quino
    [J]. PROCEEDINGS 2018 IEEE 18TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOENGINEERING (BIBE), 2018, : 170 - 176
  • [5] A body-powered functional upper limb orthosis
    Rahman, T
    Sample, W
    Seliktar, R
    Alexander, M
    Scavina, M
    [J]. JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 2000, 37 (06): : 675 - 680
  • [6] Improvement on upper limb body-powered prostheses (1921-2016): A systematic review
    Hashim, Nur Afiqah
    Abd Razak, Nasrul Anuar
    Abu Osman, Noor Azuan
    Gholizadeh, Hossein
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2018, 232 (01) : 3 - 11
  • [7] Getting a Grip on the Impact of Incidental Feedback From Body-Powered and Myoelectric Prostheses
    Gonzalez, Michael A.
    Lee, Christina
    Kang, Jiyeon
    Gillespie, R. Brent
    Gates, Deanna H.
    [J]. IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2021, 29 : 1905 - 1912
  • [8] A New Powered Humeral Rotator for Upper Limb Myoelectric Prostheses
    Mazzotti, C.
    Troncossi, M.
    Parenti-Castelli, V.
    [J]. PROCEEDINGS OF THE FOURTEENTH INTERNATIONAL FEDERATION FOR THE PROMOTION OF MECHANISM AND MACHINE SCIENCE WORLD CONGRESS, 2015, : 361 - 366
  • [9] Variable interlock mechanism joining shoulder rotation and elbow flexion for body-powered upper limb prostheses
    Kato, Akira
    Hirabayashi, Masato
    Fujie, Masakatsu G.
    Sugano, Shigeki
    [J]. 2018 WORLD AUTOMATION CONGRESS (WAC), 2018, : 312 - 317
  • [10] Ipsilateral Scapular Cutaneous Anchor System: An alternative for the harness in body-powered upper-limb prostheses
    Hichert, Mona