Biomechanical analysis of titanium-alloy and biodegradable implants in dual plate osteosynthesis for AO/ASIF type 33-C2 fractures

被引:0
|
作者
Hu, Mengmeng [1 ]
Li, Meng [1 ]
Ma, Rui [2 ]
Li, Xiaoya [1 ]
Ren, Xiaomeng [3 ]
Du, Longbo [3 ]
Zeng, Chuyang [3 ]
Li, Jiantao [1 ,4 ]
Zhang, Wei [1 ,4 ]
机构
[1] Peoples Liberat Army Gen Hosp, Med Ctr 4, Sr Dept Orthoped, 51 Fucheng Rd, Beijing 100048, Peoples R China
[2] Peoples Liberat Army Gen Hosp, Hainan Hosp, 80 Jianglin Rd, Sanya 572013, Hainan, Peoples R China
[3] Peoples Liberat Army Gen Hosp, Med Sch, 28 Fuxing Rd, Beijing 100853, Peoples R China
[4] Peoples Liberat Army Gen Hosp, Med Ctr 4, 51 Fucheng Rd, Beijing 100048, Peoples R China
关键词
DISTAL FEMUR FRACTURES; INTERNAL-FIXATION; STABILIZATION; COMPOSITES;
D O I
10.1016/j.heliyon.2024.e26213
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background and objective: Treating geriatric osteoporotic distal femur fractures has always presented challenges, but developing biodegradable materials has brought new opportunities for therapeutic intervention. Despite this progress, there currently needs to be more evidence-based biomechanical guidelines for using dual plate fixation and biodegradable materials in treating osteoporotic comminuted distal femoral fractures. In this study, finite element analysis was conducted to evaluate the mechanical effectiveness of different implant materials (titanium alloys, biodegradable materials, and combinations of both) in the fixation of physiological and osteoporotic distal femoral fractures. Methods: We constructed finite element models of 33-C2 fractures and three types of plates: the Lateral Less Invasive Stabilization System (LISS) plate, the titanium-alloy medial plate (TAP), and the biodegradable plate (BP). To evaluate the biomechanical advantages in both physiological femur (PF) and osteoporotic femur (OF) conditions, three scenarios were developed: LISS + TAP, LISS + BP, and double biodegradable plates (DBPs). Five loading conditions were applied to measure structural stiffness, fracture micromotion, and implant stress: medio-lateral four-point bending, antero-posterior four-point bending, axial loading, torsional loading, and sideways falling. Several parameters were examined, including peak Von Mises Stress (VMS) of the femur and lateral plate, maximum displacement, bending angle, torsional angle of fracture, and risk of fracture. Results: In four-point bending tests, the lateral plate of the DBPs group exhibited a slightly lower peak VMS compared to the LISS + TAP and LISS + BP groups. When subjected to axial loading, the stiffness values of the LISS + TAP (OF) were 1.42 times and 1.86 times higher than LISS + BP (OF) and DBPs (OF) groups, and the peak VMS of lateral plate of DBPs (OF) construct was approximately 2% and 16% lower than that of the LISS + TAP (OF) and LISS + BP (OF) constructs. Under torsional loading, DBPs (OF) demonstrated rotational stiffness that was respectively 2% and 52% greater than that of LISS + TAP (OF) and LISS + BP (OF). Regarding the peak VMS of femur, the values of DBPs (OF) were almost 8% and 15% lower than those of LISS + TAP (OF) and LISS + BP (OF). Conclusions: The use of DBPs at 11.33 GPa facilitated early mobilization of load-bearing joints but exhibited limited ability to support full weightbearing activities. Though LISS + TAP met practical strength requirements, one should consider the potential biological irritation and stress shielding. Thus, employing a combination of biodegradable and metal internal fixation is a valid approach to effectively treat weight-bearing joint fractures in clinical practice.
引用
收藏
页数:13
相关论文
共 6 条
  • [1] Biomechanical assessment of single LISS versus double-plate osteosynthesis in the AO type 33-C2 fractures: A finite element analysis
    Zhang, Wei
    Li, Jiantao
    Zhang, Hao
    Wang, Menglin
    Li, Lianting
    Zhou, Jianfeng
    Guo, Hui
    Li, Yang
    Tang, Peifu
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2018, 49 (12): : 2142 - 2146
  • [2] Finite element analysis of different medial fixation strategies in double-plate osteosynthesis for AO type 33-C2 Femoral fractures *
    Li, Meng
    Jiang, Yu
    Wang, Junsong
    Xu, Gaoxiang
    Wang, Daofeng
    Li, Jiantao
    Zhang, Wei
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2023, 54 : S86 - S94
  • [3] Finite element analysis of different medial fixation strategies in double-plate osteosynthesis for AO type 33-C2 Femoral fractures
    Li, Meng
    Jiang, Yu
    Wang, Junsong
    Xu, Gaoxiang
    Wang, Daofeng
    Li, Jiantao
    Zhang, Wei
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2023, 54 : S86 - S94
  • [4] A Biomechanical Comparison Study of Plate-Nail and Dual-Plate Fixation in AO/OTA 41-C2 Tibial Plateau Fractures
    Xie, Wei
    Luo, Deqing
    Xie, Li
    Zhu, Lingqi
    Zhou, Liang
    Lian, Kejian
    Lin, Dasheng
    Liu, Hui
    BIOENGINEERING-BASEL, 2024, 11 (08):
  • [5] Transarticular Approach and Retrograde Plate Osteosynthesis (TARPO) Using Implants with Angular Stability - A Series of 17 Cases of Complex Distal Femoral Fractures Type C3/AO
    Sirbu, P. D.
    Asaftei, R.
    Petreus, T.
    Lupascu, C.
    Puha, B.
    Lunca, S.
    CHIRURGIA, 2014, 109 (02) : 233 - 237
  • [6] Comparison of intramedullary nailing and minimal invasive plate osteosynthesis in the treatment of simple intra-articular fractures of the distal tibia (AO-OTA type 43 C1-C2)
    Beytemur, Ozan
    Baris, Alican
    Albay, Cem
    Yuksel, Serdar
    Caglar, Sever
    Alagoz, Ender
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2017, 51 (01) : 12 - 16