Verification calculation of multinode containment thermal hydraulic analysis code

被引:0
|
作者
Sun Y. [1 ]
Zheng Y. [1 ]
Wang D. [1 ]
Chen Q. [1 ]
机构
[1] China Nuclear Power Engineering Co., Ltd., Beijing
关键词
ATHROC; code; containment; modeling; multinode; test facility; thermal hydraulic; verification;
D O I
10.11990/jheu.202303070
中图分类号
学科分类号
摘要
This paper verifies the thermal model by modeling the comprehensive test facility and simulating test conditions to prove the validity of the self-developed multinode containment thermal hydraulic analysis code ATHROC. An analysis model was established on the basis of reliable facility information and real test results to verify the calculation performance of the code. Results reveal that the test conducted on the containment comprehensive test facility can be effectively simulated by the code ATHROC. Moreover, the calculation results are reasonable and credible, enhancing the proficiency of the model for application in engineering design. © 2023 Editorial Board of Journal of Harbin Engineering. All rights reserved.
引用
收藏
页码:1144 / 1149
页数:5
相关论文
共 14 条
  • [1] LI Gonglin, CAO Boyang, ZHOU Shuhang, Et al., Effects of inclination and flow velocity on steam condensation consisting of air on tube bundle external surfaces, Progress in nuclear energy, 136, (2021)
  • [2] LIU Feng, SUN Zhongning, CAO Boyang, Et al., Numerical investigations on the component separation phenomenon and transport behavior of steam-air-hydrogen mixture induced by condensation, International journal of thermal sciences, 172, (2022)
  • [3] ZHOU Shuhang, LI Yi, SUN Yan, Et al., Evaluations and classifications of the bundle effects on steam condensation based on broad pressure range experiments, Progress in nuclear energy, 135, (2021)
  • [4] PENG Xiang, CAO Xiaxin, CAO Jianhua, Et al., Numerical study on the effect of CO<sub>2</sub> on the heat transfer characteristics of steam condensation outside a vertical tube, Nuclear engineering and design, 391, (2022)
  • [5] SUN Yanyu, ZHENG Yuntao, MA Xiuge, Et al., Containment code verification using international standard problems [C], ICONE 27, (2019)
  • [6] SUN yanyu, Research of important parameters of HPR 1000 PCS using AHP [ J], Nuclear science and engineering, 40, pp. 124-127, (2020)
  • [7] ZHENG Yuntao, SUN Yanyu, ZHAN Jingxiang, Et al., Study on extended working condition of LOCA superposition safety injection failure design of Hualong No. 1, Science & technology vision, 17, pp. 8-11, (2021)
  • [8] SUN Yanyu, ZHENG Yuntao, MA Xiuge, Et al., Sensitivity analysis of pressure response of steel containment with natural circulation cooling, Nuclear power engineering, 40, 3, pp. 66-69, (2019)
  • [9] SUN Jing, WANG Hui, LI Jingjing, Analysis on containment thermal hydraulic behaviour under passive containment heat removal system operation condition for HPR1000, International journal of advanced nuclear reactor design and technology, 4, 1, pp. 36-42, (2022)
  • [10] SU Jiqiang, WANG Hui, SUN Zhongning, Et al., Numerical simulation of condensation heat transfer characteristics of steam containing air, CIESC journal, 65, 9, pp. 3425-3433, (2014)