The Intraoperative Pelvic Radiograph During Total Hip Arthroplasty: Is It Reliable to Estimate Leg Length?

被引:3
|
作者
Tsang, Henry [1 ,2 ]
Bouz, Tony [1 ]
Kwan, Kevin [1 ]
French, Michael [1 ]
机构
[1] Riverside Univ Hlth Syst, Moreno Valley, CA USA
[2] Riverside Univ Hlth Syst, 26520 Cactus Ave, Moreno Valley, CA 92555 USA
来源
ARTHROPLASTY TODAY | 2022年 / 16卷
关键词
Leg length discrepancy; Limb length; Total hip arthroplasty; Pelvis radiograph; DISCREPANCY; INEQUALITY;
D O I
10.1016/j.artd.2022.03.009
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Symptomatic leg length discrepancies (LLDs) are a significant complication after total hip arthroplasty. Many surgeons incorporate an intraoperative anteroposterior pelvis radiograph, to help prevent LLD; however, obtaining a high-quality radiograph is often difficult. The purpose of this study is to evaluate the accuracy and reliability of estimating LLD using different radiographic reference landmarks on suboptimal anteroposterior pelvis radiographs.Material and methods: We obtained 2 pelvis Sawbones models with attached femurs and created a true shortening of the left femur of the experimental model by 7 mm. We then obtained a series of radiographs manipulating each model in standardized increments for a total of 66 different permutations of suboptimal radiographs. Each radiograph was evaluated for LLD by 2 separate orthopedic surgeons using reference lines bisecting the following anatomic landmarks: ischial tuberosities, acetabular teardrops, obturator foramina, sacroiliac joints, and the femoral heads, to the lesser trochanters. The accuracy and reliability of each line were then analyzed.Results: The obturator foramina line yielded the most reliable LLD estimates with an intraclass correlation coefficient of 0.939. This reference line was also the most accurate, with an average difference of 1.5 mm from the true LLD (P < .001), with 95% confidence to be within 1.8 mm.Conclusion: The obturator foramen reference line on an intraoperative radiograph is an accurate and reliable tool that should be utilized by joint replacement surgeons to estimate LLD even if the radiograph is suboptimal. This estimate is reliably reproduced among multiple observers and puts the estimate within 1.8 mm of a true LLD.(c) 2022 The Authors. Published by Elsevier Inc. on behalf of The American Association of Hip and Knee Surgeons.
引用
下载
收藏
页码:9 / 14
页数:6
相关论文
共 50 条
  • [1] Leg length discrepancy assessment in total hip arthroplasty: is a pelvic radiograph sufficient?
    Hardwick-Morris, M.
    Wigmore, E.
    Twiggs, J.
    Miles, B.
    Jones, C. W.
    Yates, P. J.
    BONE & JOINT OPEN, 2022, 3 (12): : 960 - 968
  • [2] INTRAOPERATIVE MEASURING OF LEG LENGTH IN TOTAL HIP-ARTHROPLASTY
    ENGELBRECHT, E
    KLUBER, D
    HAHN, M
    CHIRURG, 1994, 65 (11): : 1034 - 1041
  • [3] An Evaluation of Sensing Technologies to Measure Intraoperative Leg Length for Total Hip Arthroplasty
    Chaurasia, Akash
    Yan, Jerry
    Li, Robert
    McCarren, Kate
    State, Claire
    Takasuka, Hannah
    Bender, Evan
    Jithendra, Aditi
    Oni, Julius K.
    Manbachi, Amir
    PROCEEDINGS OF THE 2020 DESIGN OF MEDICAL DEVICES CONFERENCE (DMD2020), 2020,
  • [4] Intraoperative pelvic motion in total hip arthroplasty
    Asayama, I
    Akiyoshi, Y
    Naito, M
    Ezoe, M
    JOURNAL OF ARTHROPLASTY, 2004, 19 (08): : 992 - 997
  • [5] Limb Length Discrepancy in Total Hip Arthroplasty: Is the Lesser Trochanter a Reliable Measure of Leg Length?
    Gallo, Matthew C.
    Chung, Brian C.
    Tucker, Douglass W.
    Piple, Amit S.
    Christ, Alexander B.
    Lieberman, Jay R.
    Heckmann, Nathanael D.
    JOURNAL OF ARTHROPLASTY, 2021, 36 (10): : 3593 - 3600
  • [6] Leg length inequality in total hip arthroplasty
    Goldstein, WM
    Gordon, A
    Branson, JJ
    ORTHOPEDICS, 2005, 28 (09) : S1037 - S1040
  • [7] Use of Intraoperative X-rays to Optimize Component Position and Leg Length During Total Hip Arthroplasty
    Ezzet, Kace A.
    McCauley, Julie C.
    JOURNAL OF ARTHROPLASTY, 2014, 29 (03): : 580 - 585
  • [8] Leg length discrepancy after total hip arthroplasty: comparison of 3 intraoperative measurement methods
    Nossa, Juan M.
    Munoz, Juan M.
    Riveros, Emilio A.
    Rueda, Guillermo
    Marquez, Diego
    Perez, Javier
    HIP INTERNATIONAL, 2018, 28 (03) : 254 - 258
  • [9] Multicenter survey about leg length discrepancy and total hip arthroplasty: preoperative and intraoperative management
    Stimolo D.
    Lo Giudice S.
    Matassi F.
    Innocenti M.
    Civinini R.
    Boniforti F.
    MUSCULOSKELETAL SURGERY, 2024, 108 (3) : 339 - 345
  • [10] LEG LENGTH DISCREPANCY IN TOTAL HIP-ARTHROPLASTY
    ABRAHAM, WD
    DIMON, JH
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 1992, 23 (02) : 201 - 209