Sensitivity studies and optimization of an impedance-based biosensor for point-of-care applications

被引:0
|
作者
Jiang T. [1 ]
Ye X. [1 ]
Tian Z. [1 ]
Shaheen M. [1 ]
Khorshed A.A. [1 ]
Feng Y. [1 ]
Li B. [1 ]
Zhang Y. [2 ]
Wang X. [1 ]
Chen J. [1 ,3 ]
机构
[1] Department of Electrical and Computer Engineering, University of Alberta, Edmonton, T6G 1H9, AB
[2] National Engineering Research Center for Biomaterials, College of Biomedical Engineering, Sichuan University, Sichuan, Chengdu
[3] Academy for Engineering & Technology, Fudan University, Shanghai
来源
关键词
Antibody detection; Electrochemical impedance spectroscopy (EIS); Impedimetric biosensors; Interdigitated electrode (IDE); Lab-on-chip; Point-of-care;
D O I
10.1016/j.biosx.2024.100479
中图分类号
学科分类号
摘要
In this study, we examined the relationship between the sensitivity of interdigitated electrode (IDE) impedimetric biosensors and the gap between the IDEs. Our aim is to find an optimal design to maximize sensitivity. A three-dimensional COMSOL model was constructed for determining the effects of electrode gap, width, and height on impedance sensitivity, revealing a singular linear correlation with the inner gap. Considering both the simulation results and fabrication processes, we have developed three IDE prototype chips with electrode gaps of 3 μm, 4 μm, and 5 μm, respectively. For empirical validation, human anti-SARS-CoV-2 monoclonal antibody (mAb) was utilized, with immobilization of the SARS-CoV-2 spike protein on the chip's surface for mAb capture. This interaction, further amplified by Protein G conjugation, induced shifts in the impedance spectrum. The sensitivity of each prototype chip was evaluated across mAb concentrations ranging from 50 ng/mL to 500 ng/mL. The 3 μm configuration emerged as the most sensitive, demonstrating the ability to detect mAb concentrations as low as 50 ng/mL, a threshold unattainable by the other designs. This outcome underscores the critical influence of reduced inter-electrode gap on enhancing biosensor detection limits. The findings from this investigation offer a foundational approach for advancing biosensor sensitivity via electrode geometric optimization, with broad potential applications extending beyond COVID-19 diagnostics to a wide spectrum of clinical and research contexts. © 2024 The Authors
引用
收藏
相关论文
共 50 条
  • [1] Impedance-based biosensors for point-of-care applications
    Fernandes, Flavio C. B.
    Bueno, Paulo R.
    2017 IEEE 12TH INTERNATIONAL CONFERENCE ON NANO/MICRO ENGINEERED AND MOLECULAR SYSTEMS (NEMS), 2017,
  • [2] Embedded unit for point-of-care impedance based biosensor readout
    Broeders, Jeroen
    Croux, Dieter
    Weustenraed, Ans
    Cleij, Thomas
    Wagner, Patrick
    De Ceuninck, Ward
    Vanaken, Wouter
    Duchateau, Stijn
    Thoelen, Ronald
    2012 IEEE 14TH INTERNATIONAL CONFERENCE ON HIGH PERFORMANCE COMPUTING AND COMMUNICATIONS & 2012 IEEE 9TH INTERNATIONAL CONFERENCE ON EMBEDDED SOFTWARE AND SYSTEMS (HPCC-ICESS), 2012, : 1571 - 1577
  • [3] Rapid, high sensitivity, point-of-care test for cardiac troponin based on optomagnetic biosensor
    Dittmer, Wendy U.
    Evers, Toon H.
    Hardeman, Willie M.
    Huijnen, Willeke
    Kamps, Rick
    de Kievit, Peggy
    Neijzen, Jaap H. M.
    Nieuwenhuis, Jeroen H.
    Sijbers, Mara J. J.
    Dekkers, Dave W. C.
    Hefti, Marco H.
    Martens, Mike F. W. C.
    CLINICA CHIMICA ACTA, 2010, 411 (11-12) : 868 - 873
  • [4] Sensitivity enhancement of an impedance-based cellular biosensor by a nanopatterned PEDOT:Nafion interface
    Choi, Jong Seob
    Kim, Byunggik
    Go, Gwangjun
    Kim, Deok-Ho
    CHEMICAL COMMUNICATIONS, 2022, 58 (72) : 10012 - 10015
  • [5] Enzyme Nanosheet-Based Electrochemical Aspartate Biosensor for Fish Point-of-Care Applications
    Rajarathinam, Thenmozhi
    Thirumalai, Dinakaran
    Jayaraman, Sivaguru
    Kim, Seonghye
    Kwon, Minho
    Paik, Hyun-jong
    Kim, Suhkmann
    Kang, Mijeong
    Chang, Seung-Cheol
    MICROMACHINES, 2022, 13 (09)
  • [6] Design and simulation of a photonic crystal resonator as a biosensor for point-of-care applications
    Zhao, Yixiong
    Vora, Kunj Himanshu
    vom Boegel, Gerd
    Seidl, Karsten
    Weidenmueller, Jens
    TM-TECHNISCHES MESSEN, 2020, 87 (7-8) : 470 - 476
  • [7] Smartphone Based Microfluidic Biosensor for Leukocyte Quantification at the Point-of-Care
    Sami, Muhammad A.
    Wagner, Kurt
    Parikh, Priya
    Hassan, Umer
    2019 IEEE HEALTHCARE INNOVATIONS AND POINT OF CARE TECHNOLOGIES (HI-POCT), 2019, : 119 - 122
  • [8] Diffraction-based BioCD biosensor for point-of-care diagnostics
    Choi, H.
    Chang, C.
    Savran, C.
    Nolte, D.
    OPTICAL DIAGNOSTICS AND SENSING XVIII: TOWARD POINT-OF-CARE DIAGNOSTICS, 2018, 10501
  • [9] An impedance-based integrated biosensor for suspended DNA characterization
    Hanbin Ma
    Richard W. R. Wallbank
    Reza Chaji
    Jiahao Li
    Yuji Suzuki
    Chris Jiggins
    Arokia Nathan
    Scientific Reports, 3
  • [10] An impedance-based integrated biosensor for suspended DNA characterization
    Ma, Hanbin
    Wallbank, Richard W. R.
    Chaji, Reza
    Li, Jiahao
    Suzuki, Yuji
    Jiggins, Chris
    Nathan, Arokia
    SCIENTIFIC REPORTS, 2013, 3