Radio frequency pulse marking of nuclear magnetization for magnetic flow metering: The impact of the flow profile

被引:1
|
作者
Schmieder, Leonhard [1 ]
Koss, Peter A. [1 ]
Kuehnemann, Frank [1 ]
Bock, Michael [2 ]
机构
[1] Fraunhofer IPM, Georges Kohler Allee 301, D-79110 Freiburg, Germany
[2] Univ Freiburg, Univ Med Ctr Freiburg, Fac Med, Dept Diagnost & Intervent Radiol,Div Med Phys, Freiburg, Germany
关键词
STEADY-STATE; ANGLE;
D O I
10.1063/5.0204641
中图分类号
O59 [应用物理学];
学科分类号
摘要
This study explores how magnetization manipulation occurs in a flowing medium over a pipe geometry using nuclear magnetic resonance methods. In particular, the experimental conditions on radio frequency pulsing and the signal detection are studied in an ultra-low frequency regime of a few kilohertz. An analytical model of the magnetization preparation is presented, which calculates the magnetization distribution of an excited flowing segment. The effective flip angle distribution is mapped to simulate the temporal development of the magnetization in the segment. The simulation results are compared to the experimental data from a flow metering setup. As a result, the quantitative impact of the flow profile on the magnetic signal is shown. (c) 2024 Author(s). All article content, except where otherwise noted, is licensed under a Creative Commons Attribution (CC BY) license
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Multiphase flow metering with nuclear magnetic resonance
    Bilgic, Attila M.
    Kunze, Johannes W.
    Stegemann, Volker
    Hogendoorn, Jankees
    Cerioni, Lucas
    Zoeteweij, Marco
    TM-TECHNISCHES MESSEN, 2015, 82 (11) : 539 - 548
  • [2] Noninvasive Magnetic-Marking-Based Flow Metering with Optically Pumped Magnetometers
    Schmieder, Leonhard
    Koss, Peter A.
    Lambrecht, Armin
    Kuehnemann, Frank
    APPLIED SCIENCES-BASEL, 2022, 12 (03):
  • [4] Quantitative velocity distributions via nuclear magnetic resonance flow metering
    O'Neill, Keelan T.
    Fridjonsson, Einar O.
    Stanwix, Paul L.
    Johns, Michael L.
    JOURNAL OF MAGNETIC RESONANCE, 2016, 269 : 179 - 185
  • [5] Flow characteristics of a metering valve in a pulse tube refrigerator
    Lu, GQ
    Cheng, P
    CRYOGENICS, 2000, 40 (11) : 721 - 727
  • [6] CALCULATION OF THE FLOW PROFILE CORRECTION FACTOR BASED ON FLOW VELOCITY DISTRIBUTION FUNCTIONS FOR ULTRASONIC FLOW METERING
    Chun, Sejong
    PROCEEDINGS OF THE ASME/JSME/KSME JOINT FLUIDS ENGINEERING CONFERENCE, 2019, VOL 4, 2019,
  • [7] ULTRASONIC FLOW METERING BASED ON TRANSIT-TIME DIFFERENTIALS WHICH ARE INSENSITIVE TO FLOW PROFILE
    LECHNER, H
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1983, 74 (03): : 955 - 959
  • [8] Investigation of the flow velocity profile in a metering section of an invasive ultrasonic flowmeter
    Raisutis, Renaldas
    FLOW MEASUREMENT AND INSTRUMENTATION, 2006, 17 (04) : 201 - 206
  • [9] ARTERIAL PULSE IMPACT ON BLOOD FLOW
    Beraia, M.
    Nebieridze, G.
    ATHEROSCLEROSIS SUPPLEMENTS, 2010, 11 (02) : 210 - 210
  • [10] The estimation of blood flow velocity profile with the Doppler Ultrasound based on adaptive pulse repetition frequency
    Yao, Peng
    He, Bingbing
    Zhang, Yufeng
    Li, Zhiyao
    Lang, Xun
    PROCEEDINGS OF 2023 4TH INTERNATIONAL SYMPOSIUM ON ARTIFICIAL INTELLIGENCE FOR MEDICINE SCIENCE, ISAIMS 2023, 2023, : 26 - 29