A microchip device based liquid-liquid-solid microextraction for the determination of permethrin and cypermethrin in water samples

被引:0
|
作者
Dowlatshah, Samira [1 ,2 ]
Ramos-Payán, María [2 ]
Saraji, Mohammad [1 ]
机构
[1] [1,Dowlatshah, Samira
[2] Ramos-Payán, María
[3] Saraji, Mohammad
来源
Saraji, Mohammad (saraji@iut.ac.ir) | 1600年 / Elsevier B.V.卷 / 235期
关键词
Acetonitrile - Ionization of gases - Liquids - Desorption - Esters - Liquid chromatography - Solvent extraction - Hexane - Organic solvents - Microprocessor chips;
D O I
暂无
中图分类号
学科分类号
摘要
In this work, for the first time, a microchip device integrating liquid-liquid-solid phase microextraction is presented. As a novel approach to microchip systems, liquid-liquid-solid microextraction was performed in a sandwiched microchip device. The microchip device consisted of three poly(methyl methacrylate) layers along with a double Y-shaped microchannel. As the stationary phase, polyacrylonitrile-C18 was synthesized and immobilized in the upper channel, while the beneath channel was used as a reservoir for the stagnant volume ratio of sample-to-extraction solvent phase. In this way, analytes were extracted from an aqueous sample through an organic phase into the stationary phase. The analytes were finally desorbed with a minimum amount of acetonitrile as the desorption solvent. Permethrin and cypermethrin were selected as the model analytes for extraction and subsequent analysis by gas chromatography-flame ionization detection. Under optimum conditions (extraction solvent; n-hexane, sample -to-extraction solvent volume ratio; 2:1, extraction time; 20 min, desorption solvent; acetonitrile, desorption volume; 200 μL, and desorption time; 15 min) detection limits were 3.5 and 6.0 ng mL−1 for permethrin and cypermethrin, respectively. Relative standard deviations for intra- and inter-day reproducibility were below 8.3%. Device-to-device precision was in the range of 8.1–9.6%. The proposed microchip device was successfully applied to determine permethrin and cypermethrin in water samples with recoveries in the range of 73–96%. © 2021 Elsevier B.V.
引用
收藏
相关论文
共 50 条
  • [1] A microchip device based liquid-liquid-solid microextraction for the determination of permethrin and cypermethrin in water samples
    Dowlatshah, Samira
    Ramos-Payan, Maria
    Saraji, Mohammad
    TALANTA, 2021, 235
  • [2] Combination of solid-phase extraction and dispersive liquid-liquid microextraction for detection of cypermethrin and permethrin in environmental water
    Yan, Hongyuan
    Han, Yehong
    Du, Jingjing
    ANALYTICAL METHODS, 2012, 4 (09) : 3002 - 3006
  • [3] Dispersive liquid-liquid microextraction based on ionic liquid and spectrophotometric determination of mercury in water samples
    Gharehbaghi, Maysam
    Shemirani, Farzaneh
    Baghdadi, Majid
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2009, 89 (01) : 21 - 33
  • [4] Simultaneous Determination of Permethrin and Deltamethrin in Water Samples by Magnetic Solid-phase Extraction coupled with Dispersive Liquid-Liquid Microextraction combined with Gas Chromatography
    Noori, Arezoo Hassan
    Rezaee, Mohammad
    Kazemipour, Maryam
    Mashayekhi, Hossein Ali
    SOUTH AFRICAN JOURNAL OF CHEMISTRY-SUID-AFRIKAANSE TYDSKRIF VIR CHEMIE, 2017, 70 : 200 - 208
  • [5] Simultaneous Determination of Deltamethrin and Permethrin in Water Samples Using Homogeneous Liquid–Liquid Microextraction via Flotation Assistance and GC-FID
    Hedayat Haddadi
    Mahboube Shirani
    Abolfazl Semnani
    Mohammad Rezaee
    Hossein Ali Mashayekhi
    Akram Hosseinian
    Chromatographia, 2014, 77 : 715 - 721
  • [6] Liquid phase microextraction integrated into a microchip device for the extraction of fluoroquinolones from urine samples
    Santigosa, Elia
    Maspoch, Santiago
    Payan, Maria Ramos
    MICROCHEMICAL JOURNAL, 2019, 145 : 280 - 286
  • [7] Simultaneous determination of cypermethrin and permethrin in pear juice by ultrasound-assisted dispersive liquid-liquid microextraction combined with gas chromatography
    Du, Jingjing
    Yan, Hongyuan
    She, Dandan
    Liu, Baomi
    Yang, Gengliang
    TALANTA, 2010, 82 (02) : 698 - 703
  • [8] Dispersive liquid-liquid microextraction and spectrophotometric determination of cobalt in water samples
    Gharehbaghi, Maysam
    Shemirani, Farzaneh
    Baghdadi, Majid
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2008, 88 (07) : 513 - 523
  • [9] Homogeneous Liquid–Liquid Microextraction for Determination of Organochlorine Pesticides in Water and Fruit Samples
    Najmeh Yazdanfar
    Yadollah Yamini
    Mahnaz Ghambarian
    Chromatographia, 2014, 77 : 329 - 336
  • [10] Liquid-liquid-solid microextraction based on membrane-protected molecularly imprinted polymer fiber for trace analysis of triazines in complex aqueous samples
    Hu, Yuling
    Wang, Yangyang
    Hu, Yufei
    Li, Gongke
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (47) : 8304 - 8311