The key comparison CCAUV.A-K6 has been carried out under the auspices of the Consultative Committee on Acoustics, Ultrasound and Vibration (CCAUV) of the International Committee of Weights and Measures (CIPM). This comparison is concerned with primary pressure calibration of laboratory standard microphones type LS2P. The participating NMI's are HBK-DPLA (Denmark), CENAM (Mexico), GUM (Poland), INMETRO (Brazil), KRISS (Korea), LNE (France), METAS (Switzerland), NMIA (Australia), NMIJ (Japan), NMISA (South Africa), NRC (Canada), UME (Turkey) and VNIIFTRI (Russia). The role of Pilot laboratory was undertaken by LNE (France). The measurements took place between March 2019 and December 2020. Two LS2P microphones were circulated. This report includes the measurement results from the participants, information about their calibration methods, and the analysis leading to the assignment of the Key Comparison Reference Values (KCRV) and Degrees of Equivalence (DoE). To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA). © 2023 BIPM and IOP Publishing Ltd.