Optimization design of strong robust controller for an LCL-type active power filter

被引:0
|
作者
Zhou J. [1 ]
Xu G. [1 ]
Zhao X. [1 ]
Yuan Y. [1 ]
Zhu Y. [1 ]
机构
[1] School of Electrical and Power Engineering, China University of Mining and Technology, Xuzhou
基金
中国国家自然科学基金;
关键词
active power filter; control delay; LCL filter; phase compensation; weak grid;
D O I
10.19783/j.cnki.pspc.211019
中图分类号
学科分类号
摘要
The LCL-active power filter can effectively compensate for the harmonic of a power grid, but an LCL filter has a resonance problem. Capacitive current proportional feedback active damping is the main way to suppress LCL resonance. However, with digital control, the resonant point will change with the grid impedance, and this makes it difficult to select the feedback coefficient. To solve this problem, this paper researches a selection method of feedback coefficient to adapt to a wide range of grid impedance variation, derives the stability conditions of the system under different feedback coefficients and harmonic frequencies, and optimizes the design of the feedback coefficient to meet the requirements. In addition, with the increase of grid impedance, the LCL resonant frequency becomes smaller and the system bandwidth becomes narrower. When the traditional quasi PR control is used to compensate for the high order harmonics, it is easy for the phase frequency curve of the system to cross the -180o line at the resonance point of the controller. This leads to instability of the system. Phase compensation is proposed to improve the phase angle at the gain of the controller, and the detailed design method is given. Theoretical analysis shows that the proposed robust controller optimization design method can ensure good harmonic compensation ability and a wider stable operation range of active power filter. Simulation and experimental results verify the correctness of the theoretical analysis. © 2022 Power System Protection and Control Press. All rights reserved.
引用
收藏
页码:140 / 152
页数:12
相关论文
共 30 条
  • [1] LIU Jianfeng, LI Meiyu, YU Guangzheng, Et al., Optimization design method of LCL filter parameters considering harmonic stability of VSC system, Power System Protection and Control, 48, 13, pp. 80-90, (2020)
  • [2] WANG Xue, GAO Yunguang, LIN Lingyan, Et al., Research status and prospect of active power filter, Power System Protection and Control, 47, 1, pp. 177-186, (2019)
  • [3] NIU Qing, SHAO Lei, CAI Huaxun, Et al., Harmonic detection and suppression of active filter device based on microgrid, Smart Power, 48, 12, pp. 46-50, (2020)
  • [4] CHEN Yun, FEI Juntao, Dynamic sliding mode control of active power filter with integral switching gain, IEEE Access, 7, pp. 21635-21638, (2019)
  • [5] SON G B, KIM H J, CHO B H., Improved modulated carrier control with on-time doubler for a single-phase shunt active power filter, IEEE Transactions on Power Electronics, 33, 2, pp. 1715-1720, (2018)
  • [6] HE Kecheng, WANG Yaohai, SHEN Qianyao, Et al., Analysis and design of the relationship between the DC capacitance and voltage fluctuation of the three-phase active power filter, Electrical Measurement & Instrumentation, 57, 16, pp. 89-95, (2020)
  • [7] WANG Lei, ZHANG Lingbo, Equivalent modeling of multi-inverters connected to the grid and optimization of resonance suppression, Power System Protection and Control, 49, 6, pp. 19-29, (2021)
  • [8] YANG Xuhong, SUN Keshuai, HE Chaojie, Grid-connected Z-source inverter based on single-cycle and dual-current loop, Journal of Electric Power Science and Technology, 36, 2, pp. 155-161, (2021)
  • [9] BAO Chenlei, RUAN Xinbo, WANG Xuehua, Et al., Step-by-step controller design for LCL-type grid-connected inverter with capacitor current feedback active-damping, IEEE Transactions on Power Electronics, 29, 3, pp. 1239-1253, (2014)
  • [10] pp. 4-20, (2015)