DESIGN OF DIGITAL H∞ ROBUST CONTROLLER FOR PHOTOVOLTAIC GRID-CONNECTED INVERTER IN WEAK GRID

被引:0
|
作者
Xie B. [1 ]
Li P. [1 ]
Su J. [1 ]
Liu T. [2 ]
Huang C. [1 ]
Huang Z. [1 ]
机构
[1] Hefei University of Technology, Research Center for Photovoltaic System Engineering of Ministry of Education, Hefei
[2] State Grid Anhui Ultra High Voltage Company, Hefei
来源
关键词
controlling time delay; digital H[!sub]∞[!/sub] controller; inverters; PV power; weak grid;
D O I
10.19912/j.0254-0096.tynxb.2021-0338
中图分类号
学科分类号
摘要
Due to the influence of grid impedance, the photovoltaic(PV)grid-connected inverter may be unstable under the weak grid. This paper proposes a digital H∞ robust controller design method for PV grid-connected inverter. Firstly, this work establishes the control model of PV grid-connected inverter under the traditional control strategy, and analyzes its stability under weak grid. In order to improve the robustness of LCL-filtered PV grid-connected inverter against the variation of grid impedance, the standard H∞ control model of PV grid-connected inverter is established in discrete domain with considering the influence of digital control delay. And the digital H∞ controller is designed by appropriately selecting the weighting functions. Compared with the traditional dual current loop control strategy, the simulation and experimental results in this paper prove that the designed digital H∞ controller significantly enhances the stability of PV grid-connected inverter in weak grid. © 2023 Science Press. All rights reserved.
引用
收藏
页码:353 / 360
页数:7
相关论文
共 26 条
  • [1] DING M, WANG W S, WANG X L, Et al., A review on the effect of large- scale PV generation on power systems, Proceedings of the CSEE, 34, 1, pp. 1-14, (2014)
  • [2] XIE B, ZHOU L, MA W, Et al., Design of high gain digital PI controller for PV grid-connected inverter[J], Acta energiae solaris sinica, 40, 9, pp. 2586-2593, (2019)
  • [3] XIE B., Stability analysis and control strategies of large-scale photovoltaic grid-connected systems under the influence of grid impedance, (2020)
  • [4] ZHENG C, ZHOU L, LIU Y J, Et al., Stability study of multi-parallel inverter system[J], Acta energiae solaris sinica, 41, 1, pp. 115-124, (2020)
  • [5] ZHOU L, ZHANG M, YANG M, Et al., Controller design of three-phase inverter with LCL filter considering the grid impedance[J], Acta energiae solaris sinica, 36, 9, pp. 2146-2151, (2015)
  • [6] RAFAEL P A, LISERRE M, BLAABJERG F, Et al., Analysis of the passive damping losses in LCL-filter-based grid converters[J], IEEE transactions on power electronics, 28, 6, pp. 2642-2646, (2013)
  • [7] PARKER S G, MCGRATH B P, HOLMES D G., Regions of active damping control for LCL filters[J], IEEE transactions on industrial applications, 50, 1, pp. 424-432, (2014)
  • [8] ZOU C Y, LIU B Y, DUAN S X, Et al., Influence of delay on system stability and delay optimization of grid-connected inverters with LCL filter [J], IEEE transactions on industrial informatics, 10, 3, pp. 1175-1784, (2014)
  • [9] PAN D H, RUAN X B, BAO C L, Et al., Capacitor-current-feedback active damping with reduced computation delay for improving robustness of LCL-type grid-connected inverter[J], IEEE transactions on power electronics, 29, 7, pp. 3414-3427, (2014)
  • [10] WANG J G, YAN J D, JIANG L, Et al., Delay-dependent stability of single-loop controlled grid-connected inverters with LCL filters[J], IEEE transactions on power electronics, 31, 1, pp. 743-757, (2016)