Preparation of radiation-sensitive dosimeter for gamma rays

被引:0
|
作者
Gafar, S.M. [1 ]
El-Tokhy, H.H. [1 ]
机构
[1] Radiation Protection and Dosimetry Department, National Center for Radiation Research and Technology, Egyptian Atomic Energy Authority, Cairo, Egypt
关键词
Dose range - Film and gel - ITS applications - Natural pigment - Naturally occurring - Poly (vinyl alcohol) (PVA) - Poly(vinyl alcohol) - Poly(vinyl alcohol) (PVA) - Research use - Thin film dosimeters;
D O I
10.1007/s10967-024-09560-0
中图分类号
学科分类号
摘要
This research uses two different dosimetry techniques (films and gels) to evaluate how γ-rays affect Cyanidin chloride. The first method relies on combining CC with poly (vinyl alcohol) to create a thin film dosimeter, while the second uses CC with gelatin to create a gel dosimeter that is more sensitive to γ-rays. The produced film or gel changes visually from red to colorless when exposed to γ-rays. The usable dose range of films was up to 35 kGy, and for gels, it was between 10 and 150 Gy. All dosimetric characteristics were studied.
引用
收藏
页码:3997 / 4004
页数:7
相关论文
共 50 条
  • [1] Radiation-Sensitive AlGaN/GaN MOS-HEMT-Based Dosimeter
    Mann, Ruby
    Rewari, Sonam
    Pal, Praveen
    Sharma, Shobha
    Gupta, R. S.
    JOURNAL OF ELECTRONIC MATERIALS, 2022, 51 (10) : 5609 - 5616
  • [2] New Radiophotoluminescence Glass Dosimeter with Specialized Radiation-Sensitive Surface Layer
    Maki, Daisuke
    Kobayashi, Hatsumi
    Sato, Fuminobu
    Murata, Isao
    Kato, Yushi
    Yamamoto, Takayoshi
    Iida, Toshiyuki
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2010, 49 (11)
  • [3] Radiation-Sensitive AlGaN/GaN MOS-HEMT-Based Dosimeter
    Ruby Mann
    Sonam Rewari
    Praveen Pal
    Shobha Sharma
    R. S. Gupta
    Journal of Electronic Materials, 2022, 51 : 5609 - 5616
  • [4] THE FERROUS SULFATE RADIATION DOSIMETER - A CALORIMETRIC CALIBRATION WITH GAMMA-RAYS
    LAZO, RM
    DEWHURST, HA
    BURTON, M
    JOURNAL OF CHEMICAL PHYSICS, 1954, 22 (08): : 1370 - 1375
  • [5] Perioperative Measurement of Radiation Exposure to Radiation-Sensitive Organs of Patients Undergoing Lumbar Surgeries Using a Thermoluminescent Dosimeter
    Chen, Xin
    Song, Youdong
    Li, Zheng
    Luo, Suming
    Yue, Baorong
    Xu, Hui
    He, Zhijian
    Ren, Zhinan
    Xu, Derong
    Li, Shugang
    WORLD NEUROSURGERY, 2018, 118 : E43 - E51
  • [6] Development of a radiation-sensitive indicator
    AbdelFattah, AA
    ElKelany, M
    AbdelRehim, F
    RADIATION PHYSICS AND CHEMISTRY, 1996, 48 (04) : 497 - 503
  • [7] RADIATION-SENSITIVE MICROSTRUCTURES IN ELECTRONICS
    DOZIER, CM
    RADIATION RESEARCH, 1983, 94 (03) : 548 - 548
  • [8] Effect of the Structure of Radiation-sensitive Group on Some Photochemical Properties of Radiation-sensitive Polymers.
    Paczkowski, Jerzy
    Sierocka, Michalina
    Zakrzewski, Andrzej
    Starczewski, Ireneusz
    Polimery/Polymers, 1984, 29 (06) : 230 - 233
  • [9] RADIATION-SENSITIVE FIELD EFFECT TRANSISTOR RESPONSE TO GAMMA-RAY IRRADIATION
    Pejovic, Milic M.
    Pejovic, Momcilo M.
    Jaksic, Aleksandar B.
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2011, 26 (01): : 25 - 31
  • [10] MUTATION-INDUCTION BY DIFFERENT DOSE-RATES OF GAMMA-RAYS IN RADIATION-SENSITIVE MUTANTS OF MOUSE LEUKEMIA-CELLS
    FURUNOFUKUSHI, I