Measurement of the Earth Tides with a Diamagnetic-Levitated Micro-Oscillator at Room Temperature

被引:1
|
作者
Leng, Yingchun [1 ,2 ]
Chen, Yiming [1 ,2 ]
Li, Rui [3 ,4 ,5 ,6 ]
Wang, Lihua [1 ,2 ]
Wang, Hao [1 ,2 ]
Wang, Lei [1 ,2 ]
Xie, Han [1 ,2 ]
Duan, Chang-Kui [3 ,4 ,5 ,6 ]
Huang, Pu [1 ,2 ]
Du, Jiangfeng [3 ,4 ,5 ,6 ,7 ,8 ]
机构
[1] Nanjing Univ, Natl Lab Solid State Microstruct, Nanjing 210093, Peoples R China
[2] Nanjing Univ, Dept Phys, Nanjing 210093, Peoples R China
[3] Univ Sci & Technol China, CAS Key Lab Microscale Magnet Resonance, Hefei 230026, Peoples R China
[4] Univ Sci & Technol China, Sch Phys Sci, Hefei 230026, Peoples R China
[5] Univ Sci & Technol China, CAS Ctr Excellence Quantum Informat & Quantum Phys, Hefei 230026, Peoples R China
[6] Hefei Natl Lab, Hefei 230088, Peoples R China
[7] Zhejiang Univ, Inst Quantum Sensing, Hangzhou 310027, Peoples R China
[8] Zhejiang Univ, Sch Phys, Hangzhou 310027, Peoples R China
基金
中国国家自然科学基金;
关键词
GRAVIMETER;
D O I
10.1103/PhysRevLett.132.123601
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The precise measurement of the gravity of Earth plays a pivotal role in various fundamental research and application fields. Although a few gravimeters have been reported to achieve this goal, miniaturization of high -precision gravimetry remains a challenge. In this work, we have proposed and demonstrated a miniaturized gravimetry operating at room temperature based on a diamagnetic levitated micro -oscillator with a proof mass of only 215 mg. Compared with the latest reported miniaturized gravimeters based on microelectromechanical systems, the performance of our gravimetry has substantial improvements in that p ffiffiffiffiffian acceleration sensitivity of 15 mu Gal= Hz and a drift as low as 61 mu Gal per day have been reached. Based on this diamagnetic levitation gravimetry, we observed Earth tides, and the correlation coefficient between the experimental data and theoretical data reached 0.97. Some moderate foreseeable improvements can develop this diamagnetic levitation gravimetry into a chip size device, making it suitable for mobile platforms such as drones. Our advancement in gravimetry is expected to facilitate a multitude of applications, including underground density surveying and the forecasting of natural hazards.
引用
收藏
页数:5
相关论文
共 8 条
  • [1] Mechanical Dissipation Below 1 μHz with a Cryogenic Diamagnetic Levitated Micro-Oscillator
    Leng, Yingchun
    Li, Rui
    Kong, Xi
    Xie, Han
    Zheng, Di
    Yin, Peiran
    Xiong, Fang
    Wu, Tong
    Duan, Chang-Kui
    Du, Youwei
    Yin, Zhang-qi
    Huang, Pu
    Du, Jiangfeng
    [J]. PHYSICAL REVIEW APPLIED, 2021, 15 (02)
  • [2] Room temperature test of the continuous spontaneous localization model using a levitated micro-oscillator
    Zheng, Di
    Leng, Yingchun
    Kong, Xi
    Li, Rui
    Wang, Zizhe
    Luo, Xiaohui
    Zhao, Jie
    Duan, Chang-Kui
    Huang, Pu
    Du, Jiangfeng
    Carlesso, Matteo
    Bassi, Angelo
    [J]. PHYSICAL REVIEW RESEARCH, 2020, 2 (01):
  • [3] Earth tides as revealed by micro-temperature measurements in the subsurface
    Jahr, Thomas
    Buntebarth, Guenter
    Sauter, Martin
    [J]. JOURNAL OF GEODYNAMICS, 2020, 136
  • [4] MEASUREMENT OF TEMPERATURE DEPENDENCE OF CRYSTAL FIELD GRADIENT AT NUCLEUS OF SOME DIAMAGNETIC RARE-EARTH SALTS
    EDMONDS, DT
    LINDOP, AJ
    [J]. PROCEEDINGS OF THE PHYSICAL SOCIETY OF LONDON, 1966, 87 (557P): : 721 - &
  • [5] A fully automated measurement system for the characterization of micro thermoelectric devices near room temperature
    Tanwar, Amit
    Lal, Swatchith
    Kaur, Rajvinder
    Padmanathan, N.
    Dalton, Eric
    Razeeb, Kafil M.
    [J]. APPLIED THERMAL ENGINEERING, 2023, 224
  • [6] An ultra-high formability at room temperature induced by continually dynamic micro-nanocrystallization of Mg rare earth alloy
    Tang, Yan
    Huo, Wangtu
    Dong, Longlong
    Zhang, Wei
    Peng, Haoran
    Zhang, Shuang
    [J]. MATERIALS LETTERS, 2023, 339
  • [7] THE MEASUREMENT OF OXYGEN ISOTOPE COMPOSITION OF EXCEEDING MICRO-WATER——CAPILLARY CO2-H2O ROOM TEMPERATURE EQUILIBRIUM METHOD
    虞福基
    刘德平
    芦承祖
    [J]. Science Bulletin, 1991, (02) : 140 - 144
  • [8] THE MEASUREMENT OF OXYGEN ISOTOPE COMPOSITION OF EXCEEDING MICRO-WATER - CAPILLARY CO2-H2O ROOM-TEMPERATURE EQUILIBRIUM METHOD
    YU, FJ
    LIU, DP
    LU, CZ
    [J]. CHINESE SCIENCE BULLETIN, 1991, 36 (02): : 140 - 144