The effectiveness of vapor-injection for an inverter air-source heat pump compared with vapor-return

被引:1
|
作者
Wang, Jijin [1 ,2 ]
Guo, Jianxiang [1 ]
Qv, Dehu [3 ]
Zhang, Linyang [1 ]
Liu, Na [1 ]
Ni, Long [2 ]
机构
[1] Qingdao Univ Technol, Sch Environm & Municipal Engn, Qingdao, Peoples R China
[2] Harbin Inst Technol, Sch Architecture & Design, Key Lab Cold Reg Urban & Rural Human Settlement En, Minist Ind & Informat Technol, Harbin 150090, Peoples R China
[3] Lanzhou Univ Technol, Sch Civil Engn, Dept Bldg Environm & Energy Applicat Engn, Lanzhou, Peoples R China
基金
中国国家自然科学基金;
关键词
Air -source heat pump; The effectiveness of vapor -injection; Heating performance; Relative entropy reduction; Vapor; -return; FLASH-TANK; PERFORMANCE; SYSTEM; CYCLE; OPTIMIZATION; COMPRESSOR; PRESSURE; R1234YF; DESIGN; R134A;
D O I
10.1016/j.applthermaleng.2024.122827
中图分类号
O414.1 [热力学];
学科分类号
摘要
The vapor-injection assisted with air-source heat pump (ASHP) has become one of the focuses in the last decade. It can improve the heating performance of the ASHP system in low ambient temperatures by experiments. However, the vapor-injection is ineffective in moderate ambient temperatures owing to the high pressure of the compressor intermediate chamber. On the other side, the effectiveness of vapor-injection is rarely discussed. Based on experiments and the thermodynamic analysis method, this paper proposes an inverter air-source heat pump (IASHP) with vapor-injection and vapor-return. With the scope from -20 degrees C to7.0 degrees C for ambient temperature, it focuses on the heating performance of the prototype with different compressor frequencies for both vapor-injection and vapor-return modes. Moreover, the effectiveness of vapor-injection is discussed. The results show that the vapor-injection is superior to vapor-return for improving the heating performance of the prototype. Not only does the vapor-injection significantly affect refrigerant mass flow rate, but it also makes the relative entropy reduction (RER) of the compressor outlet decrease by 0.025-0.03 kJ/(kg & sdot;K). In the case of ambient temperature at -4.0 degrees C, the vapor-injection improves by 6.6 % and 3.4 % for heating capacity and COP of the prototype. Besides, the effectiveness of vapor-injection lies in the RER of the compressor outlet, which is suitable for vapor-injection using different refrigerants.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Real-time Optimization of Vapor-Injection Air-Source Heat Pump based Water Heating with Extremum Seeking
    Wang, Wenyi
    Li, Yaoyu
    Cao, Feng
    [J]. 2018 ASHRAE ANNUAL CONFERENCE, 2018,
  • [2] A novel testing and theoretical approach for air-source heat-pump water heater with flash tank vapor-injection
    Liu, Xianglong
    Guang, Hu
    Zhi, Zeng
    Ping, Wang
    Zeng, Liping
    Li, Xiaohua
    [J]. ENGINEERING RESEARCH EXPRESS, 2022, 4 (04):
  • [3] Seeking a new throttle to substitute the thermostatic expansion valve in vapor-injection process for an air-source heat pump: An experimental study
    Wang, Jijin
    Qv, Dehu
    Ni, Long
    [J]. SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2022, 54
  • [4] Research on air-source heat pump coupled with economized vapor injection scroll compressor and ejector
    Xu Shuxue
    Ma Guoyuan
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2011, 34 (07): : 1587 - 1595
  • [5] Performance comparison of liquid, vapor, and liquid-vapor injection of single-screw compressor for an air-source heat pump
    Wen, Qiangyu
    Zhi, Ruiping
    Wu, Yuting
    Lei, Biao
    Du, Yanjun
    [J]. AIP ADVANCES, 2024, 14 (05)
  • [6] Experimental study on the effect of hot air supply mode on the performance of air-source heat pump with enhanced vapor injection
    Huang, Chunhui
    Du, Yongheng
    Huo, Ziheng
    Ding, Chuangchuang
    Zai, Saina
    Zhang, Zhan
    Meng, Zhaofeng
    [J]. INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2024, 19 : 1410 - 1416
  • [7] Air-source heat pump coupled with economized vapor injection scroll compressor and ejector:Design and experimental research
    XU ShuXueMA GuoYuan Beijing University of TechnologyBeijing China
    [J]. Science China(Technological Sciences), 2010, 53 (03) : 782 - 788
  • [8] Air-source heat pump coupled with economized vapor injection scroll compressor and ejector: Design and experimental research
    ShuXue Xu
    GuoYuan Ma
    [J]. Science China Technological Sciences, 2010, 53 : 782 - 788
  • [9] Air-source heat pump coupled with economized vapor injection scroll compressor and ejector:Design and experimental research
    XU ShuXue&MA GuoYuan Beijing University of Technology
    [J]. Science China Technological Sciences, 2010, (03) : 782 - 788
  • [10] Air-source heat pump coupled with economized vapor injection scroll compressor and ejector: Design and experimental research
    Xu ShuXue
    Ma GuoYuan
    [J]. SCIENCE CHINA-TECHNOLOGICAL SCIENCES, 2010, 53 (03) : 782 - 788