Flexural behavior of cold-formed thin-walled steel quadruple-limb build-up beam-column connections

被引:0
|
作者
Wen H. [1 ]
Liu Y. [1 ]
Deng F. [1 ]
Zhang F. [1 ]
机构
[1] School of Civil Engineering, Hunan University, Changsha
关键词
beam-column connections; cold-formed thin-walled steel; moment-rotational curve; monotonic loading test; quadruple-limb build-up section; self-drilling screw connections;
D O I
10.19713/j.cnki.43-1423/u.T20220771
中图分类号
学科分类号
摘要
Based on the combination of beam and column sections, a new type of beam-column connections wasproposed in order to realize the rapid assembly of the beam-column with its combination section. In order to study its flexural performance, monotonic loading tests were carried out on four groups of connections, and the failure modes and bending moment-rotation relationship of the connections were obtained through the tests. The influences of column thickness, the number of screws in the connection domain and the thickness of the end plate of the connection on the flexural performance of the connection were analyzed. This provided data for establishing an effective performance analysis model library of cold-formed thin-walled steel connections, and theoretically calculated the bearing capacity of the connection. The results show that the failure modes of this kind of connections mainly include screw pulling out or shearing, and bending failure of end plates. When the thickness of the column is doubled, the initial stiffness of the connection increases by 26% and the ultimate bending moment increases by 39.3%. When the number of screws in the connection domain is increased from three rows (6) to four rows (8), the initial stiffness of the connection only increases by 9.9%, and the ultimate bending moment only increases by 6.4%. When the thickness of the end plate increases from 4 mm to 8 mm, the initial stiffness of the connection increases by 45.5%, and the ultimate bearing capacity has no obvious change. It shows that the thickness of the column plate and the end plate of the connection have great influence on the initial stiffness of the connection, and the thickness of the column plate also has certain influence on the ultimate bearing capacity of the connection, while the number of screws has little influence on the initial stiffness and ultimate bearing capacity of the connection. When the thickness of the column is doubled at the same time, increasing the number of screws in the connection domain can improve the initial stiffness and ultimate bearing capacity of the connection. The bending moment-angle curves of four groups of connections show obvious nonlinear characteristics, and this kind of connections is determined to be semi-rigid based on Eurocode3 specification for steel structures in Europe. The ultimate bending moment of the connection is calculated through the stress analysis of the connection. By comparing the calculated value with the experimental value, it is found that the theoretical calculated value is in good agreement with the experimental value. The tested connections can also be used for box-type cold-formed light steel beam-column connections, which is conducive to rapid assembly. © 2023, Central South University Press. All rights reserved.
引用
收藏
页码:1445 / 1455
页数:10
相关论文
共 22 条
  • [1] YE Jun, MOJTABAEI S M, HAJIRASOULIHA I., Seismic performance of cold-formed steel bolted moment connections with bolting friction-slip mechanism, Journal of Constructional Steel Research, 156, pp. 122-136, (2019)
  • [2] NIE Shaofeng, ZHOU Tianhua, ZHOU Xuhong, Et al., Experimental study and numerical analysis on compressive behavior of three-limb built-up cold-formed steel columns with double box section, Journal of Southeast University (Natural Science Edition), 49, 1, pp. 25-33, (2019)
  • [3] Technical specification for low-rise cold-formed thin-walled steel buildings: JGJ 227—2011[S], (2011)
  • [4] GUO Jianxun, DENG Peng, GAO Bing, Et al., Analysis of web buckling behavior of cold-formed thin-walled I-section members, Industrial Construction, 49, 10, pp. 156-162, (2019)
  • [5] MEZA F J, BECQUE J, HAJIRASOULIHA I., Experimental study of cold-formed steel built-up beams, Journal of Structural Engineering, 146, 7, (2020)
  • [6] LAIM L, RODRIGUES J P C, DA SILVA L S., Experimental and numerical analysis on the structural behaviour of cold-formed steel beams, Thin-Walled Structures, 72, pp. 1-13, (2013)
  • [7] ZHOU Xuhong, XIANG Yi, SHI Yu, Et al., Simplified design method of cold-formed steel columns with built-up box sections, Engineering Structures, 228, (2021)
  • [8] DU Zhaoyu, ZHAO Yijie, ZHANG Qilin, Study of axial compression strength of cold-formed thin-walled built-up steel box columns, Journal of Building Structures, 35, 12, pp. 114-120, (2014)
  • [9] ZHONG Yanying, The investigation on cold-formed steel C-C beam-column joints of connections with bolt-plate, (2010)
  • [10] ALY E H A H, HANNA M T, EL-MAHDY G M., Strength and ductility of steel cold-formed section beam to column bolted connections, Facing the Challenges in Structural Engineering, (2018)