Biomechanical Evaluation of 2 Endoscopic Spine Surgery Methods for Treating Lumbar Disc Herniation: A Finite Element Study

被引:0
|
作者
Zou, Yang [1 ,2 ]
Ji, Shuo [2 ]
Yang, Hui Wen [1 ,2 ]
Ma, Tao [1 ,2 ]
Fang, Yue Kun [2 ]
Wang, Zhi Cheng [2 ]
Liu, Miao Miao [1 ]
Zhou, Ping Hui [1 ,2 ]
Bao, Zheng Qi [1 ,2 ]
Zhang, Chang Chun [1 ,2 ,4 ]
Ye, Yu Chen [1 ,2 ,3 ]
机构
[1] Bengbu Med Coll, Affiliated Hosp 1, Dept Orthopaed, Bengbu, Peoples R China
[2] Bengbu Med Coll, Anhui Prov Key Lab Tissue Transplantat, Bengbu, Peoples R China
[3] Bengbu Med Coll, Affiliated Hosp 1, Dept Orthopaed, Bengbu 233004, Peoples R China
[4] Bengbu Med Coll, Anhui Prov Key Lab Tissue Transplantat, Bengbu 233030, Peoples R China
关键词
Biomechanical; Lumbar disc herniation; Endoscopic; Finite element analysis; ADJACENT SEGMENT DISEASES; DISKECTOMY; RISK; DECOMPRESSION; FUSION; MODELS;
D O I
10.14245/ns.2347076.538
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: This study aimed to evaluate the effects of 2 endoscopic spine surgeries on the biomechanical properties of normal and osteoporotic spines. Methods: Based on computed tomography images of a healthy adult volunteer, 6 finite element models were created. After validating the normal intact model, a concentrated force of 400 N and a moment of 7.5 Nm were exerted on the upper surface of L3 to simulate 6 physiological activities of the spine. Five types of indices were used to assess the biomechanical properties of the 6 models, range of motion (ROM), maximum displacement value, intervertebral disc stress, maximum stress value, and articular protrusion stress, and by combining them with finite element stress cloud. Results: In normal and osteoporotic spines, there was no meaningful change in ROM or disc stress in the 2 surgical models for the 6 motion states. Model N1 (osteoporotic percutaneous transforaminal endoscopic discectomy model) showed a decrease in maximum displacement value of 20.28% in right lateral bending. Model M2 (unilateral biportal endoscopic model) increased maximum displacement values of 16.88% and 17.82% during left and right lateral bending, respectively. The maximum stress value of L4-5 increased by 11.72% for model M2 during left rotation. In addition, using the same surgical approach, ROM, maximum displacement values, disc stress, and maximum stress values were more significant in the osteoporotic model than in the normal model. Conclusion: In both normal and osteoporotic spines, both surgical approaches were less disruptive to the physiologic structure of the spine. Furthermore, using the same endoscopic spine surgery, normal spine biomechanical properties are superior to osteoporotic spines.
引用
收藏
页码:273 / 285
页数:13
相关论文
共 50 条
  • [1] Efficacy of Transforaminal Endoscopic Spine System (TESSYS) Technique in Treating Lumbar Disc Herniation
    Pan, Zhimin
    Ha, Yoon
    Yi, Seong
    Cao, Kai
    [J]. MEDICAL SCIENCE MONITOR, 2016, 22 : 530 - 539
  • [2] Biomechanical consequences of variations in artificial disc positioning. A finite element study on the lumbar spine
    Zander, T.
    Rohlmann, A.
    Bock, B.
    Bergmann, G.
    [J]. ORTHOPADE, 2007, 36 (03): : 205 - +
  • [3] Nonlinear finite-element analysis and biomechanical evaluation of the lumbar spine
    Wong, C
    Gehrchen, PM
    Darvann, T
    Kiær, T
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (06) : 742 - 746
  • [4] Endoscopic surgery for lumbar disc herniation - the first experience
    Maca, K.
    Duris, K.
    Smrcka, M.
    [J]. CESKA A SLOVENSKA NEUROLOGIE A NEUROCHIRURGIE, 2019, 82 (05) : 541 - 547
  • [5] A special device for endoscopic surgery of lumbar disc herniation
    Destandau, J
    [J]. NEUROLOGICAL RESEARCH, 1999, 21 (01) : 39 - 42
  • [6] Biomechanical evaluation of a novel repair strategy for intervertebral disc herniation in an ovine lumbar spine model
    Page, Mitchell I.
    Easley, Jeremiah T.
    Bonilla, Andres F.
    Patel, Vikas V.
    Puttlitz, Christian M.
    [J]. FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2022, 10
  • [7] Percutaneous Endoscopic Lumbar Discectomy in Treating Calcified Lumbar Intervertebral Disc Herniation
    Chen, Yu
    Wang, Jian-Xi
    Sun, Bin
    Cao, Peng
    Tian, Ye
    Shen, Xiao-Long
    Liu, Yang
    Chen, Hua-Jiang
    Wang, Xin-Wei
    Yuan, Wen
    Wu, Xiao-Dong
    [J]. WORLD NEUROSURGERY, 2019, 122 : E1449 - E1456
  • [8] Development of a finite element lumbar spine model to predict intervertebral disc herniation risk factors
    Rossman, Stephanie
    Meyer, Eric
    Rundell, Steven
    [J]. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2022, 25 (01) : 1 - 13
  • [9] BIOMECHANICAL STUDY OF THE CERVICAL SPINE WITH DISC IMPLANTS: A FINITE ELEMENT ANALYSIS
    Szkoda, K.
    Galaska, P.
    Zak, M.
    Pezowicz, C.
    [J]. ENGINEERING MECHANICS 2017, 2017, : 966 - 969
  • [10] Biomechanical effects of laminectomies in the human lumbar spine: a finite element study
    Spina, Nicholas T.
    Moreno, Genesis S.
    Brodke, Darrel S.
    Finley, Sean M.
    Ellis, Benjamin J.
    [J]. SPINE JOURNAL, 2021, 21 (01): : 150 - 159