Depth Encoding PET Detector Using Side Readout of Dual-layer Semi-continuous Crystals with SiPM Array

被引:0
|
作者
Zhao B. [1 ]
Huang Y. [1 ]
Wang C. [1 ]
机构
[1] Songshan Lake Materials Laboratory, Dongguan
关键词
depth encoding; dual-layer semi-continuous crystal array; PET detector; side readout;
D O I
10.7538/yzk.2023.youxian.0283
中图分类号
学科分类号
摘要
One trend in current whole-body PET scanner development is to increase the axial field-of-view. But the degradation of the spatial resolution of PET scanners due to depth of interaction uncertainty increases as the axial field-of-view increases. PET detector with depth encoding capability has become essential. In this work, a depth encoding PET detector using the side readout of dual-layer semi-continuous crystals with the SiPM array was proposed. The upper layer of the detector is a fast 1×4 LYSO array, and the lower layer is a 1×4 YSO array. The size of each crystal in each layer is 3 mm×6 mm×18 mm. The crystals of each layer were separated by an ESR reflection film, and the crystal array of the upper and lower layers were coupled by optical glue. The experimental results show that the detector can effectively identify the two layer and all crystals can be clearly resolved from the flood histograms. For the upper and lower crystal array, the average energy resolution is 11.9% and 11.7%, respectively. The detector has a good position resolution of 0.27 mm (FWHM) for the crystals. The crystal resolution map can clearly distinguish all crystal units and provide continuous depth information in the z direction. The signal maximum and sum ratio method was used to analyze the y direction height position, and the upper LYSO crystal layer is better than the lower YSO crystal layer. The experimental results reveal that the novel PET detector proposed here can be used to achieve high-performance whole-body and panoramic PET scanners. © 2023 Atomic Energy Press. All rights reserved.
引用
收藏
页码:1827 / 1834
页数:7
相关论文
共 14 条
  • [1] CHERRY S R, JONES T, KARP J S, Et al., Total-body PET: Maximizing sensitivity to create new opportunities for clinical research and patient care, Journal of Nuclear Medicine, 59, 1, pp. 3-12, (2018)
  • [2] KUANG Z, WANG X, ZHAO B, Et al., Dual-ended readout small animal PET detector by using 0.5 mm pixelated LYSO crystal arrays and SiPMs, Nuclear Instruments and Methods in Physics Research A, 917, 11, pp. 1-8, (2019)
  • [3] KUANG Z, WANG X, REN N, Et al., Design and performance of SIAT a PET: A uniform high-resolution small animal PET scanner using dual-ended readout detectors, Physics in Medicine & Biology, 65, 23, (2020)
  • [4] ZHANG J, OLCOTT P D, CHINN G, Et al., Study of the performance of a novel resolution dual-panel PET camera design dedicated to breast cancer imaging using Monte Carlo simulation, Medical physics, 34, 2, pp. 689-702, (2007)
  • [5] ZHANG J, FOUDRAY A M K, OLCOTT P D, Et al., Performance characterization of a novel thin position-sensitive avalanche photodiode for 1 mm resolution positron emission tomography, IEEE Transactions on Nuclear Science, 54, 3, pp. 415-421, (2007)
  • [6] MOHAMMADI A, INADAMA N, YOSHIDA E, Et al., Improvement of crystal identification performance for a four-layer DOI detector composed of crystals segmented by laser processing, Nuclear Instruments and Methods in Physics Research A, 866, 11, pp. 29-35, (2017)
  • [7] ZHAO Binqing, FU Chunliang, KUANG Zhonghua, Et al., Depth encoding PET detector using two and four reflector arrangements along depth of single layer LYSO array, Atomic Energy Science and Technology, 54, 3, pp. 533-541, (2020)
  • [8] AKAMATSU G, TASHIMA H, IWAO Y, Et al., Performance evaluation of a whole-body prototype PET scanner with four-layer DOI detectors, Physics in Medicine & Biology, 64, 9, (2019)
  • [9] LIU Z, MUNGAI S, NIU M, Et al., Edge effect reduction of high-resolution PET detectors using LYSO and GAGG phoswich crystals, Physics in Medicine & Biology, 68, 6, (2023)
  • [10] PROUT D L, GU Z, SHUSTEF M, Et al., A digital phoswich detector using time-over-threshold for depth of interaction in PET, Physics in Medicine & Biology, 65, 24, (2020)